Yodify Product Library
Instantly add the Smart Gap - PLC Fast Clearing Protective Gap and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Smart Gap - PLC Fast Clearing Protective Gap

Brand: Pulsar

Improve the performance and reliability of your PLC Communications.

The Smart-Gap improves the performance and reliability of your Power Line Carrier Communications by minimizing the impact of any surge induced loss of carrier signal, also known as carrier holes.

The Smart-Gap operates faster than traditional Spark Gap solutions, extinguishing surges in less than 0.5 msec. to minimize any signal loss.

Surges on the power lines cause havoc for power line communications and the typical spark gap solutions used today don’t clear fast enough and reliably enough to prevent these carrier holes. 

These communication interruptions can cause miss-operations in protective relay systems resulting in over trips on DCB (blocking) systems, delayed trips in POTT or DTT systems, or false permission to trip in DCUB (unblock) systems.

The revolutionary Smart-Gap product prevents the impact of these carrier holes by quickly clearing the surge to minimize any communication interruption.

The maintenance free Smart Gap is an ideal replacement for gas discharge tube or air gap protection which require regular maintenance.

The Smart Gap’s compact size provides an easy retrofit into existing line tuners and CCVTs.
Features
  • Fast clearing – less than 0.5 msec.
  • Significantly reduces carrier holes
  • Retrofits existing spark gap
  • Improves carrier communication reliability
  • Robust design - maintenance free

1 - 3 of 3 Part Numbers
C020-GAPMN-001
C020-GAPMN-001
2.4 kV Smart Gap - PLC Fast Clearing Protective Gap
C020-GAPMN-002
C020-GAPMN-002
4.2 kV Smart Gap - PLC Fast Clearing Protective Gap
C020-GAPMN-003
C020-GAPMN-003
6.2 kV Smart Gap - PLC Fast Clearing Protective Gap
1 - 3 of 3 Part Numbers

Specifications

Brand

Typical Firing Voltage (Constant DC)

  • 2.4 kVdc
  • 4.2 kVdc
  • 6.2 kVdc

Typical Firing Voltage (Constant 50/60 Hz))

  • 1.7 kV RMS
  • 3.1 kV RMS
  • 4.4 kV RMS

Typical Firing Voltage (1.2 x 50 µs Surge)

  • 3.0 kV peak
  • 4.2 kV peak
  • 5.1 kV peak

Maximum Time Before Firing (1.2 x 50 µs Surge)

  • 0.3 µs

Maximum Time to Extinguish Single 1.2 x 50 µs Surge

  • 100 µs

Expected Lifetime with No Degradation in Performance

  • > 10,000 of 1.2 x 50 µs surges at 8 kV/4 kA

Capacitance Maximum at 100 kHz

  • 2 pF

50/60 Hz Maximum Leakage Current (Non-Conducting State)

  • 50 µA

Gas Discharge Tube Diameter

  • 12 mm

Overall Physical Size (Including L-Bracket Mounting)

  • 2.6” x 2.4” x 2.0”

Nominal Wire Lead Length

  • 6”

Shipping Weight

  • 0.2 lbs

  • Line Tuner
  • CCVT Drain Coil
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more