Brand: R. STAHL AGR. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals.
Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power.
The desired value can be adjusted easily and conveniently via the rotary actuator.
Features- Easy adjustment of desired value on the potentiometer
- Resistance range of 100 Ω to 1 MΩ, 2 W power
- Optional delivery with connection line or terminals
1 - 12 of 21 Part Numbers
218533
Easy adjustment of desired value on the potentiometer
Resistance range of 100 Ω to 1 MΩ, 2 W power
Optional delivery with connection line or terminals
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
- Ambient temperature max. - +40 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Electrical Data
- Characteristic - linear
- Max. resistance R max - 100000.00 Ω
- Min. resistance R min - 100.00 Ω
- Nominal value - 100 kΩ
- Rated operational power - 2.00 W
- Rated operational voltage AC - 0.00 - 400.00 V
Explosion Protection
- Ambient temperature °C - -20 - 40 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 02 ATEX 2156 X
- ATEX gas certificate - PTB 02 ATEX 2156 X
- Certificates - ATEX (PTB), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
- Dust explosion protection IECEx - Ex tD A21 T80 °C
- Gas explosion protection ATEX - II 2 G Ex mb IIC T6
- Gas explosion protection IECEx - Ex mb IIC T6
- IECEX dust certificate - IECEx PTB 07.0002 X
- IECEX gas certificate - IECEx PTB 07.0002 X
General
- Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
- Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
- Product Description - Potentiometer For panel mounting
- Product Type - 8455/2-100kΩ-0/100-6
- Title Product Variant Technical Data - 8455/2-100kΩ-0/100-6 pot. dev. f.p.m.
- WebCode - 8455A
Mechanical Data
- Conductor length - 6 m
- Connection cross-section finely stranded max. - 1.50 mm²
- Degree of protection (IP) - IP66
- Enclosure material - Polyamide
- Labelling rotary actuator - 0 ... 100
- Mounting depth - 130.000 mm
- Silicone-free - Yes
- Type of connection cable - HO5VV-F, 3 x 0.75
- Weight - 0.600 kg
Mounting / Installation
- Connection type - Connection line
218534
Easy adjustment of desired value on the potentiometer
Resistance range of 100 Ω to 1 MΩ, 2 W power
Optional delivery with connection line or terminals
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
- Ambient temperature max. - +40 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Electrical Data
- Characteristic - linear
- Max. resistance R max - 10000.00 Ω
- Min. resistance R min - 100.00 Ω
- Nominal value - 10 kΩ
- Rated operational power - 2.00 W
- Rated operational voltage AC - 0.00 - 400.00 V
Explosion Protection
- Ambient temperature °C - -20 - 40 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 02 ATEX 2156 X
- ATEX gas certificate - PTB 02 ATEX 2156 X
- Certificates - ATEX (PTB), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
- Dust explosion protection IECEx - Ex tD A21 T80 °C
- Gas explosion protection ATEX - II 2 G Ex mb IIC T6
- Gas explosion protection IECEx - Ex mb IIC T6
- IECEX dust certificate - IECEx PTB 07.0002 X
- IECEX gas certificate - IECEx PTB 07.0002 X
General
- Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
- Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
- Product Description - Potentiometer For panel mounting
- Product Type - 8455/2-10kΩ-0/100-6
- Title Product Variant Technical Data - 8455/2-10kΩ-0/100-6 pot. dev. f.p.m.
- WebCode - 8455A
Mechanical Data
- Conductor length - 6 m
- Connection cross-section finely stranded max. - 1.50 mm²
- Degree of protection (IP) - IP66
- Enclosure material - Polyamide
- Labelling rotary actuator - 0 ... 100
- Mounting depth - 130.000 mm
- Silicone-free - Yes
- Type of connection cable - HO5VV-F, 3 x 0.75
- Weight - 0.600 kg
Mounting / Installation
- Connection type - Connection line
218536
Easy adjustment of desired value on the potentiometer
Resistance range of 100 Ω to 1 MΩ, 2 W power
Optional delivery with connection line or terminals
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
- Ambient temperature max. - +40 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Electrical Data
- Characteristic - linear
- Max. resistance R max - 1000.00 Ω
- Min. resistance R min - 100.00 Ω
- Nominal value - 1 kΩ
- Rated operational power - 2.00 W
- Rated operational voltage AC - 0.00 - 400.00 V
Explosion Protection
- Ambient temperature °C - -20 - 40 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 02 ATEX 2156 X
- ATEX gas certificate - PTB 02 ATEX 2156 X
- Certificates - ATEX (PTB), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
- Dust explosion protection IECEx - Ex tD A21 T80 °C
- Gas explosion protection ATEX - II 2 G Ex mb IIC T6
- Gas explosion protection IECEx - Ex mb IIC T6
- IECEX dust certificate - IECEx PTB 07.0002 X
- IECEX gas certificate - IECEx PTB 07.0002 X
General
- Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
- Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
- Product Description - Potentiometer For panel mounting
- Product Type - 8455/2-1kΩ-0/100-6
- Title Product Variant Technical Data - 8455/2-1kΩ-0/100-6 pot. dev. f.p.m.
- WebCode - 8455A
Mechanical Data
- Conductor length - 6 m
- Connection cross-section finely stranded max. - 1.50 mm²
- Degree of protection (IP) - IP66
- Enclosure material - Polyamide
- Labelling rotary actuator - 0 ... 100
- Mounting depth - 130.000 mm
- Silicone-free - Yes
- Type of connection cable - HO5VV-F, 3 x 0.75
- Weight - 0.600 kg
Mounting / Installation
- Connection type - Connection line
218537
Easy adjustment of desired value on the potentiometer
Resistance range of 100 Ω to 1 MΩ, 2 W power
Optional delivery with connection line or terminals
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
- Ambient temperature max. - +40 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Electrical Data
- Characteristic - linear
- Max. resistance R max - 1000.00 Ω
- Min. resistance R min - 100.00 Ω
- Nominal value - 1 kΩ
- Rated operational power - 2.00 W
- Rated operational voltage AC - 0.00 - 400.00 V
Explosion Protection
- Ambient temperature °C - -20 - 40 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 02 ATEX 2156 X
- ATEX gas certificate - PTB 02 ATEX 2156 X
- Certificates - ATEX (PTB), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
- Dust explosion protection IECEx - Ex tD A21 T80 °C
- Gas explosion protection ATEX - II 2 G Ex mb IIC T6
- Gas explosion protection IECEx - Ex mb IIC T6
- IECEX dust certificate - IECEx PTB 07.0002 X
- IECEX gas certificate - IECEx PTB 07.0002 X
General
- Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
- Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
- Product Description - Potentiometer For panel mounting
- Product Type - 8455/2-1kΩ-0/10-6
- WebCode - 8455A
Mechanical Data
- Conductor length - 6 m
- Connection cross-section finely stranded max. - 1.50 mm²
- Degree of protection (IP) - IP66
- Enclosure material - Polyamide
- Labelling rotary actuator - 0 ... 10
- Mounting depth - 130.000 mm
- Silicone-free - Yes
- Type of connection cable - HO5VV-F, 3 x 0.75
- Weight - 0.600 kg
Mounting / Installation
- Connection type - Connection line
218538
Easy adjustment of desired value on the potentiometer
Resistance range of 100 Ω to 1 MΩ, 2 W power
Optional delivery with connection line or terminals
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
- Ambient temperature max. - +40 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Electrical Data
- Characteristic - linear
- Max. resistance R max - 2200.00 Ω
- Min. resistance R min - 100.00 Ω
- Nominal value - 2,2 kΩ
- Rated operational power - 2.00 W
- Rated operational voltage AC - 0.00 - 400.00 V
Explosion Protection
- Ambient temperature °C - -20 - 40 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 02 ATEX 2156 X
- ATEX gas certificate - PTB 02 ATEX 2156 X
- Certificates - ATEX (PTB), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
- Dust explosion protection IECEx - Ex tD A21 T80 °C
- Gas explosion protection ATEX - II 2 G Ex mb IIC T6
- Gas explosion protection IECEx - Ex mb IIC T6
- IECEX dust certificate - IECEx PTB 07.0002 X
- IECEX gas certificate - IECEx PTB 07.0002 X
General
- Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
- Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
- Product Description - Potentiometer For panel mounting
- Product Type - 8455/2-2,2kΩ-0/100-6
- WebCode - 8455A
Mechanical Data
- Conductor length - 6 m
- Connection cross-section finely stranded max. - 1.50 mm²
- Degree of protection (IP) - IP66
- Enclosure material - Polyamide
- Labelling rotary actuator - 0 ... 100
- Mounting depth - 130.000 mm
- Silicone-free - Yes
- Type of connection cable - HO5VV-F, 3 x 0.75
- Weight - 0.600 kg
Mounting / Installation
- Connection type - Connection line
218539
Easy adjustment of desired value on the potentiometer
Resistance range of 100 Ω to 1 MΩ, 2 W power
Optional delivery with connection line or terminals
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
- Ambient temperature max. - +40 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Electrical Data
- Characteristic - linear
- Max. resistance R max - 2200.00 Ω
- Min. resistance R min - 100.00 Ω
- Nominal value - 2,2 kΩ
- Rated operational power - 2.00 W
- Rated operational voltage AC - 0.00 - 400.00 V
Explosion Protection
- Ambient temperature °C - -20 - 40 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 02 ATEX 2156 X
- ATEX gas certificate - PTB 02 ATEX 2156 X
- Certificates - ATEX (PTB), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
- Dust explosion protection IECEx - Ex tD A21 T80 °C
- Gas explosion protection ATEX - II 2 G Ex mb IIC T6
- Gas explosion protection IECEx - Ex mb IIC T6
- IECEX dust certificate - IECEx PTB 07.0002 X
- IECEX gas certificate - IECEx PTB 07.0002 X
General
- Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
- Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
- Product Description - Potentiometer For panel mounting
- Product Type - 8455/2-2,2kΩ-0/10-6
- WebCode - 8455A
Mechanical Data
- Conductor length - 6 m
- Connection cross-section finely stranded max. - 1.50 mm²
- Degree of protection (IP) - IP66
- Enclosure material - Polyamide
- Labelling rotary actuator - 0 ... 10
- Mounting depth - 130.000 mm
- Silicone-free - Yes
- Type of connection cable - HO5VV-F, 3 x 0.75
- Weight - 0.600 kg
Mounting / Installation
- Connection type - Connection line
218541
Easy adjustment of desired value on the potentiometer
Resistance range of 100 Ω to 1 MΩ, 2 W power
Optional delivery with connection line or terminals
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
- Ambient temperature max. - +40 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Electrical Data
- Characteristic - linear
- Max. resistance R max - 22000.00 Ω
- Min. resistance R min - 100.00 Ω
- Nominal value - 22 kΩ
- Rated operational power - 2.00 W
- Rated operational voltage AC - 0.00 - 400.00 V
Explosion Protection
- Ambient temperature °C - -20 - 40 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 02 ATEX 2156 X
- ATEX gas certificate - PTB 02 ATEX 2156 X
- Certificates - ATEX (PTB), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
- Dust explosion protection IECEx - Ex tD A21 T80 °C
- Gas explosion protection ATEX - II 2 G Ex mb IIC T6
- Gas explosion protection IECEx - Ex mb IIC T6
- IECEX dust certificate - IECEx PTB 07.0002 X
- IECEX gas certificate - IECEx PTB 07.0002 X
General
- Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
- Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
- Product Description - Potentiometer For panel mounting
- Product Type - 8455/2-22kΩ-0/10-6
- Title Product Variant Technical Data - 8455/2-22kΩ-0/10-6 pot. dev. f.p.m.
- WebCode - 8455A
Mechanical Data
- Conductor length - 6 m
- Connection cross-section finely stranded max. - 1.50 mm²
- Degree of protection (IP) - IP66
- Enclosure material - Polyamide
- Labelling rotary actuator - 0 ... 10
- Mounting depth - 130.000 mm
- Silicone-free - Yes
- Type of connection cable - HO5VV-F, 3 x 0.75
- Weight - 0.600 kg
Mounting / Installation
- Connection type - Connection line
218542
Easy adjustment of desired value on the potentiometer
Resistance range of 100 Ω to 1 MΩ, 2 W power
Optional delivery with connection line or terminals
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
- Ambient temperature max. - +40 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Electrical Data
- Characteristic - linear
- Max. resistance R max - 4700.00 Ω
- Min. resistance R min - 100.00 Ω
- Nominal value - 4,7 kΩ
- Rated operational power - 2.00 W
- Rated operational voltage AC - 0.00 - 400.00 V
Explosion Protection
- Ambient temperature °C - -20 - 40 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 02 ATEX 2156 X
- ATEX gas certificate - PTB 02 ATEX 2156 X
- Certificates - ATEX (PTB), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
- Dust explosion protection IECEx - Ex tD A21 T80 °C
- Gas explosion protection ATEX - II 2 G Ex mb IIC T6
- Gas explosion protection IECEx - Ex mb IIC T6
- IECEX dust certificate - IECEx PTB 07.0002 X
- IECEX gas certificate - IECEx PTB 07.0002 X
General
- Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
- Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
- Product Description - Potentiometer For panel mounting
- Product Type - 8455/2-4,7kΩ-0/100-6
- Title Product Variant Technical Data - 8455/2-4,7kΩ-0/100-6 pot. dev. f.p.m.
- WebCode - 8455A
Mechanical Data
- Conductor length - 6 m
- Connection cross-section finely stranded max. - 1.50 mm²
- Degree of protection (IP) - IP66
- Enclosure material - Polyamide
- Labelling rotary actuator - 0 ... 100
- Mounting depth - 130.000 mm
- Silicone-free - Yes
- Type of connection cable - HO5VV-F, 3 x 0.75
- Weight - 0.600 kg
Mounting / Installation
- Connection type - Connection line
218543
Easy adjustment of desired value on the potentiometer
Resistance range of 100 Ω to 1 MΩ, 2 W power
Optional delivery with connection line or terminals
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
- Ambient temperature max. - +40 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Electrical Data
- Characteristic - linear
- Max. resistance R max - 4700.00 Ω
- Min. resistance R min - 100.00 Ω
- Nominal value - 4,7 kΩ
- Rated operational power - 2.00 W
- Rated operational voltage AC - 0.00 - 400.00 V
Explosion Protection
- Ambient temperature °C - -20 - 40 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 02 ATEX 2156 X
- ATEX gas certificate - PTB 02 ATEX 2156 X
- Certificates - ATEX (PTB), IECEx (PTB)
- Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
- Dust explosion protection IECEx - Ex tD A21 T80 °C
- Gas explosion protection ATEX - II 2 G Ex mb IIC T6
- Gas explosion protection IECEx - Ex mb IIC T6
- IECEX dust certificate - IECEx PTB 07.0002 X
- IECEX gas certificate - IECEx PTB 07.0002 X
General
- Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
- Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
- Product Description - Potentiometer For panel mounting
- Product Type - 8455/2-4,7kΩ-0/10-6
- WebCode - 8455A
Mechanical Data
- Conductor length - 6 m
- Connection cross-section finely stranded max. - 1.50 mm²
- Degree of protection (IP) - IP66
- Enclosure material - Polyamide
- Labelling rotary actuator - 0 ... 10
- Mounting depth - 130.000 mm
- Silicone-free - Yes
- Type of connection cable - HO5VV-F, 3 x 0.75
- Weight - 0.600 kg
Mounting / Installation
- Connection type - Connection line
218544
Easy adjustment of desired value on the potentiometer
Resistance range of 100 Ω to 1 MΩ, 2 W power
Optional delivery with connection line or terminals
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
- Ambient temperature max. - +40 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Electrical Data
- Characteristic - linear
- Max. resistance R max - 10000.00 Ω
- Min. resistance R min - 100.00 Ω
- Nominal value - 10 kΩ
- Rated operational power - 2.00 W
- Rated operational voltage AC - 0.00 - 400.00 V
Explosion Protection
- Ambient temperature °C - -20 - 40 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2
- ATEX dust certificate - PTB 02 ATEX 2156 X
- ATEX gas certificate - PTB 02 ATEX 2156 X
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex mb IIC T6
- Gas explosion protection IECEx - Ex mb IIC T6
- IECEX dust certificate - IECEx PTB 07.0001 U
- IECEX gas certificate - IECEx PTB 07.0001 U
General
- Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
- Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
- Product Description - Potentiometer For panel mounting
- Product Type - 8455/4-10kΩ-0/100
- WebCode - 8455A
Mechanical Data
- Connection cross-section finely stranded max. - 1.50 mm²
- Degree of protection (IP) - IP66
- Enclosure material - Polyamide
- Labelling rotary actuator - 0 ... 100
- Mounting depth - 130.000 mm
- Silicone-free - Yes
- Terminal degree of protection (IP) - IP20
- Weight - 0.600 kg
Mounting / Installation
- Connection type - Screw connector
218545
Easy adjustment of desired value on the potentiometer
Resistance range of 100 Ω to 1 MΩ, 2 W power
Optional delivery with connection line or terminals
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
- Ambient temperature max. - +40 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Electrical Data
- Characteristic - linear
- Max. resistance R max - 10000.00 Ω
- Min. resistance R min - 100.00 Ω
- Nominal value - 10 kΩ
- Rated operational power - 2.00 W
- Rated operational voltage AC - 0.00 - 400.00 V
Explosion Protection
- Ambient temperature °C - -20 - 40 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2
- ATEX dust certificate - PTB 02 ATEX 2156 X
- ATEX gas certificate - PTB 02 ATEX 2156 X
- Certificates - ATEX (PTB), IECEx (PTB)
- Gas explosion protection ATEX - II 2 G Ex mb IIC T6
- Gas explosion protection IECEx - Ex mb IIC T6
- IECEX dust certificate - IECEx PTB 07.0001 U
- IECEX gas certificate - IECEx PTB 07.0001 U
General
- Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
- Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
- Product Description - Potentiometer For panel mounting
- Product Type - 8455/4-10kΩ-0/10
- Title Product Variant Technical Data - 8455/4-10kΩ-0/10 pot. dev. f.p.m.
- WebCode - 8455A
Mechanical Data
- Connection cross-section finely stranded max. - 1.50 mm²
- Degree of protection (IP) - IP66
- Enclosure material - Polyamide
- Labelling rotary actuator - 0 ... 10
- Mounting depth - 130.000 mm
- Silicone-free - Yes
- Terminal degree of protection (IP) - IP20
- Weight - 0.600 kg
Mounting / Installation
- Connection type - Screw connector
1 - 12 of 21 Part Numbers