Brand: R. STAHL AG

R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. 

Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. 

The desired value can be adjusted easily and conveniently via the rotary actuator.
Features
  • Easy adjustment of desired value on the potentiometer
  • Resistance range of 100 Ω to 1 MΩ, 2 W power
  • Optional delivery with connection line or terminals

1 - 12 of 21 Part Numbers
218533
218533
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Electrical Data

  • Characteristic - linear
  • Max. resistance R max - 100000.00 Ω
  • Min. resistance R min - 100.00 Ω
  • Nominal value - 100 kΩ
  • Rated operational power - 2.00 W
  • Rated operational voltage AC - 0.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 02 ATEX 2156 X
  • ATEX gas certificate - PTB 02 ATEX 2156 X
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
  • Dust explosion protection IECEx - Ex tD A21 T80 °C
  • Gas explosion protection ATEX - II 2 G Ex mb IIC T6
  • Gas explosion protection IECEx - Ex mb IIC T6
  • IECEX dust certificate - IECEx PTB 07.0002 X
  • IECEX gas certificate - IECEx PTB 07.0002 X

General

  • Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
  • Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
  • Product Description - Potentiometer For panel mounting
  • Product Type - 8455/2-100kΩ-0/100-6
  • Title Product Variant Technical Data - 8455/2-100kΩ-0/100-6 pot. dev. f.p.m.
  • WebCode - 8455A

Mechanical Data

  • Conductor length - 6 m
  • Connection cross-section finely stranded max. - 1.50 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyamide
  • Labelling rotary actuator - 0 ... 100
  • Mounting depth - 130.000 mm
  • Silicone-free - Yes
  • Type of connection cable - HO5VV-F, 3 x 0.75
  • Weight - 0.600 kg

Mounting / Installation

  • Connection type - Connection line
218534
218534
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Electrical Data

  • Characteristic - linear
  • Max. resistance R max - 10000.00 Ω
  • Min. resistance R min - 100.00 Ω
  • Nominal value - 10 kΩ
  • Rated operational power - 2.00 W
  • Rated operational voltage AC - 0.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 02 ATEX 2156 X
  • ATEX gas certificate - PTB 02 ATEX 2156 X
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
  • Dust explosion protection IECEx - Ex tD A21 T80 °C
  • Gas explosion protection ATEX - II 2 G Ex mb IIC T6
  • Gas explosion protection IECEx - Ex mb IIC T6
  • IECEX dust certificate - IECEx PTB 07.0002 X
  • IECEX gas certificate - IECEx PTB 07.0002 X

General

  • Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
  • Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
  • Product Description - Potentiometer For panel mounting
  • Product Type - 8455/2-10kΩ-0/100-6
  • Title Product Variant Technical Data - 8455/2-10kΩ-0/100-6 pot. dev. f.p.m.
  • WebCode - 8455A

Mechanical Data

  • Conductor length - 6 m
  • Connection cross-section finely stranded max. - 1.50 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyamide
  • Labelling rotary actuator - 0 ... 100
  • Mounting depth - 130.000 mm
  • Silicone-free - Yes
  • Type of connection cable - HO5VV-F, 3 x 0.75
  • Weight - 0.600 kg

Mounting / Installation

  • Connection type - Connection line
218535
218535
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals
218536
218536
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Electrical Data

  • Characteristic - linear
  • Max. resistance R max - 1000.00 Ω
  • Min. resistance R min - 100.00 Ω
  • Nominal value - 1 kΩ
  • Rated operational power - 2.00 W
  • Rated operational voltage AC - 0.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 02 ATEX 2156 X
  • ATEX gas certificate - PTB 02 ATEX 2156 X
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
  • Dust explosion protection IECEx - Ex tD A21 T80 °C
  • Gas explosion protection ATEX - II 2 G Ex mb IIC T6
  • Gas explosion protection IECEx - Ex mb IIC T6
  • IECEX dust certificate - IECEx PTB 07.0002 X
  • IECEX gas certificate - IECEx PTB 07.0002 X

General

  • Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
  • Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
  • Product Description - Potentiometer For panel mounting
  • Product Type - 8455/2-1kΩ-0/100-6
  • Title Product Variant Technical Data - 8455/2-1kΩ-0/100-6 pot. dev. f.p.m.
  • WebCode - 8455A

Mechanical Data

  • Conductor length - 6 m
  • Connection cross-section finely stranded max. - 1.50 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyamide
  • Labelling rotary actuator - 0 ... 100
  • Mounting depth - 130.000 mm
  • Silicone-free - Yes
  • Type of connection cable - HO5VV-F, 3 x 0.75
  • Weight - 0.600 kg

Mounting / Installation

  • Connection type - Connection line
218537
218537
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Electrical Data

  • Characteristic - linear
  • Max. resistance R max - 1000.00 Ω
  • Min. resistance R min - 100.00 Ω
  • Nominal value - 1 kΩ
  • Rated operational power - 2.00 W
  • Rated operational voltage AC - 0.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 02 ATEX 2156 X
  • ATEX gas certificate - PTB 02 ATEX 2156 X
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
  • Dust explosion protection IECEx - Ex tD A21 T80 °C
  • Gas explosion protection ATEX - II 2 G Ex mb IIC T6
  • Gas explosion protection IECEx - Ex mb IIC T6
  • IECEX dust certificate - IECEx PTB 07.0002 X
  • IECEX gas certificate - IECEx PTB 07.0002 X

General

  • Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
  • Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
  • Product Description - Potentiometer For panel mounting
  • Product Type - 8455/2-1kΩ-0/10-6
  • WebCode - 8455A

Mechanical Data

  • Conductor length - 6 m
  • Connection cross-section finely stranded max. - 1.50 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyamide
  • Labelling rotary actuator - 0 ... 10
  • Mounting depth - 130.000 mm
  • Silicone-free - Yes
  • Type of connection cable - HO5VV-F, 3 x 0.75
  • Weight - 0.600 kg

Mounting / Installation

  • Connection type - Connection line
218538
218538
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Electrical Data

  • Characteristic - linear
  • Max. resistance R max - 2200.00 Ω
  • Min. resistance R min - 100.00 Ω
  • Nominal value - 2,2 kΩ
  • Rated operational power - 2.00 W
  • Rated operational voltage AC - 0.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 02 ATEX 2156 X
  • ATEX gas certificate - PTB 02 ATEX 2156 X
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
  • Dust explosion protection IECEx - Ex tD A21 T80 °C
  • Gas explosion protection ATEX - II 2 G Ex mb IIC T6
  • Gas explosion protection IECEx - Ex mb IIC T6
  • IECEX dust certificate - IECEx PTB 07.0002 X
  • IECEX gas certificate - IECEx PTB 07.0002 X

General

  • Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
  • Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
  • Product Description - Potentiometer For panel mounting
  • Product Type - 8455/2-2,2kΩ-0/100-6
  • WebCode - 8455A

Mechanical Data

  • Conductor length - 6 m
  • Connection cross-section finely stranded max. - 1.50 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyamide
  • Labelling rotary actuator - 0 ... 100
  • Mounting depth - 130.000 mm
  • Silicone-free - Yes
  • Type of connection cable - HO5VV-F, 3 x 0.75
  • Weight - 0.600 kg

Mounting / Installation

  • Connection type - Connection line
218539
218539
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Electrical Data

  • Characteristic - linear
  • Max. resistance R max - 2200.00 Ω
  • Min. resistance R min - 100.00 Ω
  • Nominal value - 2,2 kΩ
  • Rated operational power - 2.00 W
  • Rated operational voltage AC - 0.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 02 ATEX 2156 X
  • ATEX gas certificate - PTB 02 ATEX 2156 X
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
  • Dust explosion protection IECEx - Ex tD A21 T80 °C
  • Gas explosion protection ATEX - II 2 G Ex mb IIC T6
  • Gas explosion protection IECEx - Ex mb IIC T6
  • IECEX dust certificate - IECEx PTB 07.0002 X
  • IECEX gas certificate - IECEx PTB 07.0002 X

General

  • Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
  • Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
  • Product Description - Potentiometer For panel mounting
  • Product Type - 8455/2-2,2kΩ-0/10-6
  • WebCode - 8455A

Mechanical Data

  • Conductor length - 6 m
  • Connection cross-section finely stranded max. - 1.50 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyamide
  • Labelling rotary actuator - 0 ... 10
  • Mounting depth - 130.000 mm
  • Silicone-free - Yes
  • Type of connection cable - HO5VV-F, 3 x 0.75
  • Weight - 0.600 kg

Mounting / Installation

  • Connection type - Connection line
218541
218541
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Electrical Data

  • Characteristic - linear
  • Max. resistance R max - 22000.00 Ω
  • Min. resistance R min - 100.00 Ω
  • Nominal value - 22 kΩ
  • Rated operational power - 2.00 W
  • Rated operational voltage AC - 0.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 02 ATEX 2156 X
  • ATEX gas certificate - PTB 02 ATEX 2156 X
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
  • Dust explosion protection IECEx - Ex tD A21 T80 °C
  • Gas explosion protection ATEX - II 2 G Ex mb IIC T6
  • Gas explosion protection IECEx - Ex mb IIC T6
  • IECEX dust certificate - IECEx PTB 07.0002 X
  • IECEX gas certificate - IECEx PTB 07.0002 X

General

  • Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
  • Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
  • Product Description - Potentiometer For panel mounting
  • Product Type - 8455/2-22kΩ-0/10-6
  • Title Product Variant Technical Data - 8455/2-22kΩ-0/10-6 pot. dev. f.p.m.
  • WebCode - 8455A

Mechanical Data

  • Conductor length - 6 m
  • Connection cross-section finely stranded max. - 1.50 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyamide
  • Labelling rotary actuator - 0 ... 10
  • Mounting depth - 130.000 mm
  • Silicone-free - Yes
  • Type of connection cable - HO5VV-F, 3 x 0.75
  • Weight - 0.600 kg

Mounting / Installation

  • Connection type - Connection line
218542
218542
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Electrical Data

  • Characteristic - linear
  • Max. resistance R max - 4700.00 Ω
  • Min. resistance R min - 100.00 Ω
  • Nominal value - 4,7 kΩ
  • Rated operational power - 2.00 W
  • Rated operational voltage AC - 0.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 02 ATEX 2156 X
  • ATEX gas certificate - PTB 02 ATEX 2156 X
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
  • Dust explosion protection IECEx - Ex tD A21 T80 °C
  • Gas explosion protection ATEX - II 2 G Ex mb IIC T6
  • Gas explosion protection IECEx - Ex mb IIC T6
  • IECEX dust certificate - IECEx PTB 07.0002 X
  • IECEX gas certificate - IECEx PTB 07.0002 X

General

  • Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
  • Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
  • Product Description - Potentiometer For panel mounting
  • Product Type - 8455/2-4,7kΩ-0/100-6
  • Title Product Variant Technical Data - 8455/2-4,7kΩ-0/100-6 pot. dev. f.p.m.
  • WebCode - 8455A

Mechanical Data

  • Conductor length - 6 m
  • Connection cross-section finely stranded max. - 1.50 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyamide
  • Labelling rotary actuator - 0 ... 100
  • Mounting depth - 130.000 mm
  • Silicone-free - Yes
  • Type of connection cable - HO5VV-F, 3 x 0.75
  • Weight - 0.600 kg

Mounting / Installation

  • Connection type - Connection line
218543
218543
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Electrical Data

  • Characteristic - linear
  • Max. resistance R max - 4700.00 Ω
  • Min. resistance R min - 100.00 Ω
  • Nominal value - 4,7 kΩ
  • Rated operational power - 2.00 W
  • Rated operational voltage AC - 0.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 02 ATEX 2156 X
  • ATEX gas certificate - PTB 02 ATEX 2156 X
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tD A21 T80 °C
  • Dust explosion protection IECEx - Ex tD A21 T80 °C
  • Gas explosion protection ATEX - II 2 G Ex mb IIC T6
  • Gas explosion protection IECEx - Ex mb IIC T6
  • IECEX dust certificate - IECEx PTB 07.0002 X
  • IECEX gas certificate - IECEx PTB 07.0002 X

General

  • Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
  • Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
  • Product Description - Potentiometer For panel mounting
  • Product Type - 8455/2-4,7kΩ-0/10-6
  • WebCode - 8455A

Mechanical Data

  • Conductor length - 6 m
  • Connection cross-section finely stranded max. - 1.50 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyamide
  • Labelling rotary actuator - 0 ... 10
  • Mounting depth - 130.000 mm
  • Silicone-free - Yes
  • Type of connection cable - HO5VV-F, 3 x 0.75
  • Weight - 0.600 kg

Mounting / Installation

  • Connection type - Connection line
218544
218544
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Electrical Data

  • Characteristic - linear
  • Max. resistance R max - 10000.00 Ω
  • Min. resistance R min - 100.00 Ω
  • Nominal value - 10 kΩ
  • Rated operational power - 2.00 W
  • Rated operational voltage AC - 0.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2
  • ATEX dust certificate - PTB 02 ATEX 2156 X
  • ATEX gas certificate - PTB 02 ATEX 2156 X
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Gas explosion protection ATEX - II 2 G Ex mb IIC T6
  • Gas explosion protection IECEx - Ex mb IIC T6
  • IECEX dust certificate - IECEx PTB 07.0001 U
  • IECEX gas certificate - IECEx PTB 07.0001 U

General

  • Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
  • Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
  • Product Description - Potentiometer For panel mounting
  • Product Type - 8455/4-10kΩ-0/100
  • WebCode - 8455A

Mechanical Data

  • Connection cross-section finely stranded max. - 1.50 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyamide
  • Labelling rotary actuator - 0 ... 100
  • Mounting depth - 130.000 mm
  • Silicone-free - Yes
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.600 kg

Mounting / Installation

  • Connection type - Screw connector
218545
218545
R. STAHL Potentiometer for Panel Mounting
Easy adjustment of desired value on the potentiometer

Resistance range of 100 Ω to 1 MΩ, 2 W power

Optional delivery with connection line or terminals

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C -20 °C ... +55 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Electrical Data

  • Characteristic - linear
  • Max. resistance R max - 10000.00 Ω
  • Min. resistance R min - 100.00 Ω
  • Nominal value - 10 kΩ
  • Rated operational power - 2.00 W
  • Rated operational voltage AC - 0.00 - 400.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2
  • ATEX dust certificate - PTB 02 ATEX 2156 X
  • ATEX gas certificate - PTB 02 ATEX 2156 X
  • Certificates - ATEX (PTB), IECEx (PTB)
  • Gas explosion protection ATEX - II 2 G Ex mb IIC T6
  • Gas explosion protection IECEx - Ex mb IIC T6
  • IECEX dust certificate - IECEx PTB 07.0001 U
  • IECEX gas certificate - IECEx PTB 07.0001 U

General

  • Functional Description - R. STAHL Series 8455 potentiometers are intended for installation in panels and are delivered with a connection line or with terminals. Their resistance is between 100 Ω and 1 MΩ, they are designed for 2 W power. The desired value can be adjusted easily and conveniently via the rotary actuator.
  • Highlights - Easy adjustment of desired value on the potentiometer Resistance range of 100 Ω to 1 MΩ, 2 W power Optional delivery with connection line or terminals
  • Product Description - Potentiometer For panel mounting
  • Product Type - 8455/4-10kΩ-0/10
  • Title Product Variant Technical Data - 8455/4-10kΩ-0/10 pot. dev. f.p.m.
  • WebCode - 8455A

Mechanical Data

  • Connection cross-section finely stranded max. - 1.50 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyamide
  • Labelling rotary actuator - 0 ... 10
  • Mounting depth - 130.000 mm
  • Silicone-free - Yes
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.600 kg

Mounting / Installation

  • Connection type - Screw connector
1 - 12 of 21 Part Numbers

Documentation

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more