Yodify Product Library
Instantly add the WKt Series Low Energy Heat of Compression Compressed Air Dryers (Partial Stream) and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
WKt Series Low Energy Heat of Compression Compressed Air Dryers (Partial Stream)
Brand: ZanderParker Zander WKt series compressed air dryers are fully automatic dryers which utilize partial flow regeneration principles to dry compressed air down to a pressure dew-point of -20°C.
Partial stream HOC low energy compressed air dryers that utilize excess heat from oil-free compressors for regeneration, providing volume flows of up to 14500 m³/h @ 7 bar g.
Features- Volume flows up to 14500 m³/h @ 7 bar g
- Maximum operating pressure 10 bar g - higher pressures on request
- Pressure dew point: -10 to -50°C - lower dew points available on request
- Multitronic controller as standard (ZDMC optional)
- Operation with up to 3 compressors (optional)
- Operation with low flows (optional)
- Very low operating costs by using the compressor heat - only cost is power for the control unit
- Very quiet operation - no purge / expansion, no blower or vacuum pump
- Low service costs - no heater, no blower, no load changes
Many additional options are available to suit specific customer requirements.
Specifications
Brand
Controller Type
- Multitronic
Minimum Operating Temperature
- 68° F
- 20° C
Maximum Operating Pressure
- 145 psig
- 10 barg
Height
- 2355 to 4045 mm
Connection Type
- Flange According to EN 1092-1
Minimum Ambient Temperature
- 1.5° C (Insulation Required if Temperature is below 15° C)
Minimum Operating Pressure
- 4 barg
Maximum Flow Rate (at 101 psig / PDP - 4° F)
- 247 to 8534 CFM
Power Consumption
- Depends on Design
Depth
- 950 to 2500 mm
Dryer Technology
- Fully Automatic Adsorption Dryer with Heat of Compressor Usage for Partial Flow Regeneration
Maximum Operating Temperature
- 104° F
- 40° C
Maximum Ambient Temperature (°C)
- 50° C
Electrical Requirements
- 24 Vdc
Port Size
- DN 40 to DN 200
Width
- 1250 to 3650 mm
Weight
- 500 to 13150 kg
Water Consumption
- 1.40 m³/hour to 47.70 m³/hour
IP Protection Rating
- IP54
Approvals & Certifications
- Others on Request
- PED
Pressure Dew Point
- 14 to -58° F
- -10 to -50° C