Yodify Product Library
Instantly add the DM3600 Intelligent Panel Meter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
DM3600 Intelligent Panel Meter
Brand: Status InstrumentsThe DM3600 is an intelligent digital panel meter that can accept inputs from a wide variety of sensors and display the signal digitally.
In addition, it has the facility to accept up to two option ‘Pods’ which can be either isolated (4 to 20) mA re-transmission or two alarm relays. The DM3600 is available in two models.
The DM3600U which is a universal input panel indicator and the DM3600A, a universal panel indicator with totaliser functions.
All functions are programmable via the integral front panel keys or via the optional RS-485 serial communications port using the Modbus protocol.
The DM3600 supports TFML (Transfer Function Module Library) i.e the ability to download custom functionality by means of standard modules available from the web site.
This allows pre-written or custom control functions to be quickly and easily incorporated.
The DM3600A totaliser function enables non-volatile storage of the integrated total to be maintained within the unit, even after loss of power. Output options can be selected to operate on Process Variable (PV) or Total.
Features- Universal Input
- Flow Totaliser / Batch Functions
- 6 Digit Display
- Programmable Relay & Current Outputs
- Loop Power Supply
- RS485 Comms Option
Specifications
Brand
Accuracy
- Cold Junction Error: ± 0.5° C (± 0.9° F)
- Cold Junction Tracking: 0.05° C/°C
- Current Input: 0.05 % of Full Scale ± 0.05 % of Reading
- Isolated Re-Transmission: 0.07 % of Full Scale
- RTD: 0.1° C (32.18° F) ± 0.05 % of Reading
- Voltage Input / RTD: ± 0.04 % of Full Scale or ± 0.04 % of Reading or ± 0.5° C (32.9° F), whichever is greater
Alarm
- High/Low
Approvals & Certifications
- EMC BS EN 61326, BS EN 61010-1
- IEC 707 FVO
- UL 94VO
Communication
- 4-Wire or 2-Wire Half-Duplex RS-485
- RS-485 Modbus Communication Protocol
Consumption
- Power Consumption: 10 VA (Worst Case) 6 VA Typical
Current
- 0 to 23 mA
- Excitation Current: 1 mA
- Ripple Current: < 3 µA
Electrical Connectors
- 5-Way Tension Clamp Connector
- Termination: Screw Terminal
Electrical Contacts
- 2 x Changeover Relays with Common Wiper
Environmental Protection
- IP65
Frequency
- 50/60 Hz
Humidity
- 10 to 90 % Relative Humidity
Input
- ± 10 mA
- ± 100 mV
- ± 20 mA
- -10-10 V
- 4-20 mA
Input Impedance
- 1 Megaohm - Voltage
- 20 ohms - Current
Interface Connection
- 8-Way RJ45 Connector (Supplied with Matching Plug & 1 Meter Cable)
Isolation
- 500 Vac
Load
- Dual Relay Alarm / Pulse - AC, Max.
- Dual Relay Alarm / Pulse - DC, Max.
Materials of Construction
- ABS/PC
Operating Temperature
- -30° to 60° C (-22° to 140° F)
Operating Temperature - Sensor
- -200° to 850° C (-328° to 1,562° F)
Operation
- Electrical Life: 100,000 Operations at Rated Load
- Mechanical Life: 50 Million Operations
Output
- 0-10 V
- 0 to 100 mA (Active or Passive) - Isolated Re-Transmission
Output Load
- Active: Max.
Power
- Dual Relay Alarm / Pulse - AC, Max.
- Dual Relay Alarm / Pulse - DC, Max.
Power Supply
- 20-35 Vdc
- 90-264 Vac (50 to 60) Hz
Power Supply Effect
- Voltage Effect: 0.2 μA/V
Resistance
- 50 ohms/Leg - Max.
Resistance Effect
- 0.002° C/ohms - Lead Resistance Effect
RTD Type
- Ni120
- Pt100
Sensor, Probe Type
- B Thermocouple
- E Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- N Thermocouple
- RTD
- R Thermocouple
- S Thermocouple
- T Thermocouple
Span - Minimum
- > 10 % of Range
Stability
- 1 µA/°C
Storage Temperature
- -50° to 85° C (-58° to 185° F)
Supply Voltage
- 30 V (Passive Mode) - Max.
Temperature Range
- Cold Junction Range: -20° to 60° C (-4° to 140° F)
Thermal Drift
- Current Input: 0.02 %/°C
- RTD - Span: 0.002 %/°C
- RTD - Zero: 0.004 ohms/°C
- RTD - Zero: 4 µV/°C
- Voltage Input / RTD Span: 0.01 %/°C
Voltage
- Dual Relay Alarm / Pulse - AC, Max.
- Dual Relay Alarm / Pulse - DC, Max.