EchoPod DX10 Ultrasonic Level Sensor
Brand: FlowlineThe general-purpose ultrasonic level transmitter provides continuous level measurement up to 49.2 inches (1.25 meters) with a selectable 0-5 Vdc, 0-10 Vdc or 976 to 2,000 Hz frequency signal output, and is configured via our free WebCal software.
Select the voltage output for interface with Analog input cards. Select the frequency output for interface with discrete input cards.
This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is widely selected for small day tank, skid, IBC, sump and process tank level applications.
Features- Continuous non-contact level measurement up to 49.2 inches (1.25 meters)
- Selectable voltage or frequency (discrete) signal outputs
- Configuration is fast and easy via webcal software and USB adapter
- Narrow 2" beam width and short 2" dead band optimized for small tanks
- PVDF transducer and 6P polycarbonate enclosure for corrosive liquids
- Automatic temperature compensation for accurate measurement
Specifications
Brand
Accuracy
- 0.125” (3 mm)
Ambient Temperature Range
- -35° to 60° C (-31° to 140° F)
Approvals & Certifications
- CE
- FM (C,US)
- RoHS
BSP Connection
- G 1” Male
Cable Length
- 4 feet (1.21 metres)
Cable Material
- Polyurethane - Jacket
Cable Type
- 6-Conductor, Shielded
Configuration
- WebCal PC
- Windows® USB 2.0
Consumption
- 0.5 W
Current
- 15 mA Nominal (Sink Current)
Deadband
- 2” (5 cm)
Enclosure, Body Material
- Polycarbonate
Environmental Protection
- Corrosion Resistant Material
- Typical 6P, Encapsulated, Corrosion Resistant & Submersible
Gasket Material
- Viton - Mount
Input Signal
- Signal Invert: 5-0 V, 10-0 V, 2,000 to 976 Hz - Signal Invert
Materials of Construction
- PVDF - Transducer Material
- Santoprene - Strain Relief
Media
- Liquids: Corrosive, Sticky or Dirty Liquids
NPT Connection
- 1” NPT Male
Operating Pressure
- psi: 30 (kPa: 200, bar: 2) - Max.
Output
- Signal Output: 0-10 V at 976 to 2,000 Hz
- Signal Output: 0-5 V at 976 to 2,000 Hz
Pressure Range
- bar: 0 to 2
- kPa: 0 to 200
- psi: 0 to 30
Process Temperature
- -7° to 60° C (20° to 140° F)
Range
- 49.2” (1.25 metres)
Resolution
- 0.019” (0.5 mm)
Sensor, Probe Type
- Ultrasonic
Supply Voltage
- 12-24 Vdc
- Chemical Feed
- Cooling Towers
- IBC or Drum
- Skid or Machine