Brand: R. STAHL AGR. STAHL Series 8402 ammeters are installed in Ex e type of protection enclosures. They provide measured values for Ex i circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
Features- Ammeters in various versions, for Ex i circuits and Ex e enclosures
- Quicker comparison of measured values using externally adjustable red pointers on the device
- Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
1 - 4 of 4 Part Numbers
144303
Ammeters in various versions, for Ex i circuits and Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Components
- Scale - without
Electrical Data
- Internal resistance R i - 2.93 Ω
- Measuring range max. - 20 mA
- Measuring range min. - 0 mA
- Short-circuit current max. - 150 mA
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 98 ATEX 2101
- Certificates - ATEX (PTB), IECEx (PTB)
- CSA gas certificate - CSA LR99488017
- EAC gas certificate - STV 04.B01690
- Gas explosion protection ATEX - II 2 G Ex ib IIC T6
- Gas explosion protection IECEx - Ex ib IIC T6
- IECEX gas certificate - IECEx PTB 06.0006
General
- Functional Description - R. STAHL Series 8402 ammeters are installed in Ex e type of protection enclosures. They provide measured values for Ex i circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex i circuits and Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
- Product Description - Moving coil ammeter Direct measuring For Ex i electrical circuit
- Product Type - 8402/3-11
- Title Product Variant Technical Data - 8402/3-11 Ammeter Ex i 0-20mA
- WebCode - 8402A
Mechanical Data
- Accuracy class - 1.5
- Connection cross-section finely stranded max. - 2.50 mm²
- Connection cross-section solid max. - 4.00 mm²
- Connection cross-section solid min. - 0.50 mm²
- Degree of protection (IP) - IP20
- Depth - 71.500 mm
- Enclosure material - Polyamide
- Height - 85.000 mm
- Silicone-free - Yes
- Terminal degree of protection (IP) - IP20
- Weight - 0.800 kg
- Width - 89.000 mm
Safety Data
- Internal capacitance C i - ~ 0
- Internal inductance L i - 68,5 µH
144304
Ammeters in various versions, for Ex i circuits and Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Components
- Scale - without
Electrical Data
- Internal resistance R i - 2.93 Ω
- Measuring range max. - 20 mA
- Measuring range min. - 4 mA
- Short-circuit current max. - 150 mA
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 98 ATEX 2101
- Certificates - ATEX (PTB), IECEx (PTB)
- CSA gas certificate - CSA LR99488017
- EAC gas certificate - STV 04.B01690
- Gas explosion protection ATEX - II 2 G Ex ib IIC T6
- Gas explosion protection IECEx - Ex ib IIC T6
- IECEX gas certificate - IECEx PTB 06.0006
General
- Functional Description - R. STAHL Series 8402 ammeters are installed in Ex e type of protection enclosures. They provide measured values for Ex i circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex i circuits and Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
- Product Description - Moving coil ammeter Direct measuring For Ex i electrical circuit
- Product Type - 8402/3-12
- Title Product Variant Technical Data - 8402/3-12 Ammeter Ex i 4-20mA
- WebCode - 8402A
Mechanical Data
- Accuracy class - 1.5
- Connection cross-section finely stranded max. - 2.50 mm²
- Connection cross-section solid max. - 4.00 mm²
- Connection cross-section solid min. - 0.50 mm²
- Degree of protection (IP) - IP20
- Depth - 71.500 mm
- Enclosure material - Polyamide
- Height - 85.000 mm
- Silicone-free - Yes
- Terminal degree of protection (IP) - IP20
- Weight - 0.800 kg
- Width - 89.000 mm
Safety Data
- Internal capacitance C i - ~ 0
- Internal inductance L i - 68,5 µH
144305
Ammeters in various versions, for Ex i circuits and Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Components
- Scale - without
Electrical Data
- Internal resistance R i - 2.93 Ω
- Measuring range max. - 20 mA
- Measuring range min. - 0 mA
- Rated operational current AC - 0.020 - 0.020 A
- Rated operational voltage AC - 60.00 V
- Rated operational voltage DC - 60.00 V
- Short-circuit current max. - 150 mA
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 98 ATEX 2101
- Certificates - ATEX (PTB), EAC (STV), IECEx (PTB)
- CSA gas certificate - CSA LR99488017
- EAC gas certificate - STV 04.B01690
- Gas explosion protection ATEX - II 2 G Ex ib IIC T6
- Gas explosion protection IECEx - Ex ib IIC T6
- IECEX gas certificate - IECEx PTB 06.0006
General
- Functional Description - R. STAHL Series 8402 ammeters are installed in Ex e type of protection enclosures. They provide measured values for Ex i circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex i circuits and Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
- Product Description - Moving coil ammeter Direct measuring For Ex i electrical circuit
- Product Type - 8402/5
- Title Product Variant Technical Data - 8402/5 Ammeter Ex i
- WebCode - 8402A
Mechanical Data
- Accuracy class - 1.5
- Connection cross-section finely stranded max. - 2.50 mm²
- Connection cross-section solid max. - 4.00 mm²
- Connection cross-section solid min. - 0.50 mm²
- Degree of protection (IP) - IP20
- Depth - 71.500 mm
- Enclosure material - Polyamide
- Height - 85.000 mm
- Silicone-free - Yes
- Terminal degree of protection (IP) - IP20
- Weight - 0.222 kg
- Width - 89.000 mm
Safety Data
- Internal capacitance C i - ~ 0
- Internal inductance L i - 68,5 µH
144306
Ammeters in various versions, for Ex i circuits and Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Components
- Scale - without
Electrical Data
- Internal resistance R i - 2.93 Ω
- Measuring range max. - 20 mA
- Measuring range min. - 0 mA
- Short-circuit current max. - 150 mA
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - PTB 98 ATEX 2101
- Certificate EAC - TS RU S-DE.GB04.B.00253
- Certificates - ATEX (PTB), EAC (STV), IECEx (PTB)
- CSA gas certificate - CSA LR99488017
- EAC gas certificate - STV 04.B01690
- Gas explosion protection ATEX - II 2 G Ex ib IIC T6
- Gas explosion protection EAC - 1 Ex ib IIC T6
- Gas explosion protection IECEx - Ex ib IIC T6
- IECEX gas certificate - IECEx PTB 06.0006
General
- Functional Description - R. STAHL Series 8402 ammeters are installed in Ex e type of protection enclosures. They provide measured values for Ex i circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex i circuits and Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
- Product Description - Moving coil ammeter Direct measuring For Ex i electrical circuit
- Product Type - 8402/5
- Title Product Variant Technical Data - 8402/5 Ammeter Ex i for panel mounting
- WebCode - 8402A
Mechanical Data
- Accuracy class - 1.5
- Connection cross-section finely stranded max. - 2.50 mm²
- Connection cross-section solid max. - 4.00 mm²
- Connection cross-section solid min. - 0.50 mm²
- Degree of protection (IP) - IP20
- Depth - 71.500 mm
- Enclosure material - Polyamide
- Height - 85.000 mm
- Silicone-free - Yes
- Terminal degree of protection (IP) - IP20
- Weight - 0.230 kg
- Width - 89.000 mm
Safety Data
- Internal capacitance C i - ~ 0
- Internal inductance L i - 68,5 µH
1 - 4 of 4 Part Numbers