Yodify Product Library
Add the Pilot-Operated Pressure Reducing Valve, In-Line Mounting - Series R4R / R4R*P2 to your store or catalog  
Book Your Demo and See How
or create your store

Pilot-Operated Pressure Reducing Valve, In-Line Mounting - Series R4R / R4R*P2

Brand: Parker Hannifin

As versatile pilot operated pressure reducing valves for in-line mounting, Parker's series R4R with manual adjustment and series R4R*P2 with proportional solenoid adjustment provide high flow and ensure a constant pressure in the secondary part of the hydraulic system. 

Independent of the primary pressure, the secondary pressure is reduced to the pressure setting. 

In order to avoid unintended motion of the actuator, the valves are normally closed. 

For single functions – where no manifold blocks are used – the valves can be directly placed in the pipework. 

Series R4R*P2 has additionally a proportional solenoid operated pilot stage and a cartridge main stage. 

The optimum performance can be achieved in combination with the digital amplifier module PCD00A-400.
Features
  • Wide range of options - suitable for almost every application 
  • Flexible, versatile mounting in any orientation - makes integration easy 
  • Normally closed position - avoids unintended actuator motion 
  • High flow up to 450 l/min in size NG32 (G1¼") - optimum efficiency in relation to valve size
  • Short delivery time - no warehousing necessary 
  • Pilot operated with manual adjustment 
  • Available with 2 ports (L-body) or with 3 ports (T-body)
  • 3 pressure stages: 105, 210, 350 bar 
  • 3 adjustment modes:     
    • hand knob     
    • acorn nut with lead seal
    • cylinder lock

Specifications

Maximum Operating Pressure

  • Ports A, B, X 350 bar, Port Y Depressurized
  • Ports A, X 350 bar, Port B, Y Depressurized

Actuation Type

  • Manual, Solenoid

Maximum Operating Temperature

  • 60° C

Seal Material

  • NBR
  • FPM

Mounting Type

  • Pipe Mounting

Weight

  • 3.2 - 8.4 kg

Flow Rate

  • Depending on Size, 60 - 450 L/min

Minimum Operating Temperature

  • -20° C

Maximum Pressure Setting

  • 350 bar

Drain Option

  • Drain Line External from Pilot Head (Y1)

  • Suitable for General Hydraulic Applications
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more