Yodify Product Library
Instantly add the 450 Commercial & Domestic Boiler Analyser and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

450 Commercial & Domestic Boiler Analyser

Brand: Kane International Limited

Oxygen measuring commercial analyser with a H₂ compensated CO sensor
Features
  • Rotary switch for ease of use
  • Logs and prints reports with optional infra-red printer
    • Combustion
    • Pressure
    • Let-by and Tightness
    • Temperature
    • CO build up

Specifications

AC Battery Charger (Optional)

  • Input: 110 VAC/220 VAC Nominal
  • Output: 10 VAC Off Load

Ambient Operating Range

  • +0°C to +40°C / 32°F - 104°F
  • 10% to 90% Relative Humidity, Non-Condensing

Battery Life

  • > 12 Hours Using Alkaline AA Cells
  • 4 AA Cells

Gas Measurement Accuracy

  • Carbon Dioxide: ± 0.3% of Reading
  • Carbon Monoxide (KANE450CO & KANE450COH): ± 10 ppm 100 ppm
  • Efficiency: ± 1.0% of Reading
  • Excess Air: ± 0.2%
  • Nitric Oxide (NO) (High Range): ± 5 ppm 30 ppm
  • Oxygen: ± 0.2%

Gas Measurement Range

  • Carbon Dioxide: 0 - 30%
  • Carbon Monoxide (KANE450CO): 0 - 2000 ppm Nom (4000 ppm, Max
  • Carbon Monoxide (KANE450COH): 0 - 4,000 ppm
  • Efficiency: 0 - 99.9%
  • Excess Air: 0 - 250%
  • Nitric Oxide (NO) (High Range): 0 to 1000 ppm
  • Nitric Oxide (NO) (Low Range): 0 to 100 ppm
  • Oxygen: 0 - 21%

Gas Measurement Resolution

  • Carbon Monoxide (KANE450CO & KANE450COH), Nitric Oxide (NO) (Low & High Range): 1 ppm
  • Oxygen, Carbon Dioxide, Efficiency, Excess Air: 0.1%

Pre-Programmed Fuels

  • Natural Gas, Light Oil, Propane, Butane, LPG, Wood Pellets

Pressure Measurement Accuracy

  • For ± 100 Pa Range: ± 3 Pa
  • For ± 20 Pa Range: ± 0.5 Pa
  • For ± 2000 Pa & ± 80 hPa Range: ± 3 % of Reading

Pressure Measurement Range

  • ± 100 Pa
  • ± 20 Pa
  • ± 2000 Pa
  • ± 80 hPa

Pressure Measurement Resolution

  • For ± 20 Pa & ± 100 Pa Range: 0.1 Pa
  • For ± 2000 Pa Range: 1 Pa
  • For ± 80 hPa Range: 0.01 hPa

Sensor, Probe

  • L300 mm / 11.8” x Dia 6 mm / 0.25” with 200 mm / 7.8” Long Stainless Steel Shaft, Typical K Thermocouple & 3 M / 10 feet Long Neoprene Hose

Storage Capacity

  • 20 Pressure Tests
  • 20 Room CO Tests
  • 20 Temperature Tests
  • 20 Tightness Tests
  • 99 Combustion Tests

Temperature Measurement Accuracy

  • Flue Temperature, Inlet Temperature (External Sensor): ± 2.0°C +0.3% of Reading
  • Inlet Temperature (Internal Sensor): ± 1.0°C ± 0.3% of Reading

Temperature Measurement Range

  • Flue Temperature, Inlet Temperature (External Sensor): 0°C - 600°C
  • Inlet Temperature (Internal Sensor): 0°C to 50°C

Temperature Measurement Resolution

  • Flue Temperature, Inlet Temperature (Internal & External Sensor): 0.1°C
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more