Yodify Product Library
Instantly add the Aztec AW635 High Range Manganese Analyzer and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Aztec AW635 High Range Manganese Analyzer
Brand: ABB GroupThe Aztec 600 high range manganese analyzer provides reliable and accurate measurement of manganese levels in surface and ground waters for efficient control of manganese removal processes.
The Aztec 600 high range manganese analyzer provides a wide operating range of up to 10 ppm Mn (10 mg/l), making it ideal for monitoring manganese levels in source waters.
Featuring ABB's intuitive menu-driven software and the unique self-cleaning Aztec fluid handling system, users benefit from an analyzer that is both simple-to-operate and maintain.
Features- Analysis of up to 3 sample streams
- Automatic 2-point calibration
- Automatic background color compensation
- Automatic sample dilution to maximize range
- Self-cleaning measurement system
- Intuitive software with full color graphical display
- Data logging and graphical process trending
- Full audit trail capability
- Secure data archiving to SD Card
1 - 12 of 120 Part Numbers
AW63551000010
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 90 to 264 Vac, 50/60 Hz
- Manual - English
- Certification - None
AW63551000011
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 90 to 264 Vac, 50/60 Hz
- Manual - English
- Certification - Certificate of Calibration
AW63551000020
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 90 to 264 Vac, 50/60 Hz
- Manual - French
- Certification - None
AW63551000021
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 90 to 264 Vac, 50/60 Hz
- Manual - French
- Certification - Certificate of Calibration
AW63551000030
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 90 to 264 Vac, 50/60 Hz
- Manual - Italian
- Certification - None
AW63551000031
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 90 to 264 Vac, 50/60 Hz
- Manual - Italian
- Certification - Certificate of Calibration
AW63551000040
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 90 to 264 Vac, 50/60 Hz
- Manual - German
- Certification - None
AW63551000041
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 90 to 264 Vac, 50/60 Hz
- Manual - German
- Certification - Certificate of Calibration
AW63551000050
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 90 to 264 Vac, 50/60 Hz
- Manual - Spanish
- Certification - None
AW63551000051
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 90 to 264 Vac, 50/60 Hz
- Manual - Spanish
- Certification - Certificate of Calibration
AW63551001010
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 18 to 36 Vdc
- Manual - English
- Certification - None
AW63551001011
- Range - 0.02 to 10 ppm Mn
- Number of Streams - Measuring 1 Stream
- Communication - None
- Enclosure - Standard
- Power Supply - 18 to 36 Vdc
- Manual - English
- Certification - Certificate of Calibration
1 - 12 of 120 Part Numbers
Specifications
Brand
Measurement Range
- 0.02 to 10 ppm Mn (0.02 to 10 mg/L)
Accuracy / Maximum Measured Error
- ± 7 % of Reading or ± 0.005 ppm for 5 to 10 ppm, whichever is greater
- ± 5 % of Reading or ± 0.005 ppm for 0 to 5 ppm, whichever is greater
Repeatability
- ± 5 % of Reading or ± 0.005 ppm, whichever is greater
Resolution
- 0.001 ppm or 1 ppb
Calibration
- 2-Point, Automatic Calibration
Operating Temperature
- 5° to 45° C (41° to 113° F)
Sample Temperature
- 1° to 40° C (32° to 104° F)
Sample Pressure
- 5 psi Max.
Flow Rate
- Sample: Continuous 200 to 500 mL/min
Humidity
- Up to 95 % Relative Humidity, Non-Condensing
Display
- Color, TFT, LCD with built-in backlight and brightness Adjustment
Environmental Protection
- IP 31
Materials of Construction
- Door: Acrylic
- Lower Tray: 20 % Glass-loaded Polypropylene
- Main Enclosure: Noryl
- Electronics Enclosure: 10 % Glass-loaded Polycarbonate
Power Supply
- 18-36 Vdc optional
- 100-240 Vac Max. 50/60 Hz ± 10 %
Power Consumption
- 100 W Max. - DC
- 75 W Max. - AC
Certifications & Approvals
- EMC
- CE
- cULus
- LV Directives
Communication
- PROFIBUS DP V1.0
- Manganese removal from drinking water:
- monitoring of source water manganese levels from either surface waters or boreholes. Seasonal changes and water level tables can significantly affect or influence the concentration of manganese in source waters
- measurement of water post aeration / filtration to monitor removal process / efficiency
Documentation
Brochure
- Course description - Z206e Aztec600 | External version pdf 48 KB
- Course description - Z253e Continuous Water Analyzer (CWA) Range | External version pdf 49 KB
- Security advisory – DataManagerPro file permissions escalation vulnerability | ABB-VU-PAMP-089290 pdf 23 KB
- Version matrix - AW630 pdf 11 KB
- Supplementary information - Driver AW630 PROFIBUS DP | Aztec 600 pdf 33 KB