Yodify Product Library
Add the Kayden CLASSIC 830 Thermal Flow Switch to your store or catalog  
Book Your Demo and See How
or create your store

Kayden CLASSIC 830 Thermal Flow Switch

Brand: Kayden Instruments

The Kayden CLASSIC 830 Flow Switch & Transmitter features a precision-welded, highly accurate stainless steel sensor.
 
Ideal for liquids, gases, and slurries in a clean or dirty process, it is available with 3/4” Female NPT connections in a horizontal or vertical orientation.
 
All Kayden models feature a rugged flameproof enclosure with blind or lens covers available.
 
  • Process Connections
    • 3/4" Female NPT
  • Adjustable Set Point Range
    • 0-20,000 cc/s
  • Sensor Assembly Body Length
    • 3.5" (8.8 cm)
  • Sensor Mounting Orientation
    • Horizontal or Vertical
  • Input Power
    • 12-24 Vdc & 115-230 Vac, 50-60 Hz
  • Operating Pressure - Maximum
    • psi  3480
    • kPa  24,000
    • bar  240
  • Temperature Range - Sensor
    • -45° to 200° C
    • -50° to 392° F
  • Local Enclosure
    • Aluminum Flameproof
    • 1" Female NPT
  • Local Enclosure Cover
    • Flameproof Blind Cover or Flameproof Glass Lens Cover
  • Wetted Materials
    • 316/316L Stainless Steel with Nickel Braze
  • Outputs/Communications
    • Two Independent Relays - SPDT
    • 4-20 mA
    • Modbus
  • Approvals
    • CSA
    • Single Seal
    • NACE
    • NEMA 4, 4X, 6P, IP65/67

1 - 12 of 90 Part Numbers
830-RA3D-0035-AH0A-C1-B0A-1E
830-RA3D-0035-AH0A-C1-B0A-1E
KAYDEN CLASSIC Thermal Flow & Level Switch, Modbus, In-Line, 3/4" FNPT, SST Ni Braze, Blind, CSA
830-RA3D-0035-AH0A-C1-B0A-9E
830-RA3D-0035-AH0A-C1-B0A-9E
KAYDEN CLASSIC Thermal Flow & Level Switch, Modbus, In-Line, 3/4" FNPT, SST Ni Braze, Blind, FM
830-RA3D-0035-AH0A-C1-B0A1E
830-RA3D-0035-AH0A-C1-B0A1E
KAYDEN® CLASSIC® Thermal Flow & Level Switch, Modbus, In-Line, 3/4" FNPT, 316 SST Sensor with Nickel Braze, Local Electronics Enclosure with Blind Cover, Approvals: C CSA Us (UL Standards)
  • Process Connections: 3/4" FNPT
  • Adjustable Set Point Range: 0-20,000 cc/s
  • Sensor Mounting Orientation: Horizontal  
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Selected
  • Wetted Materials:
    • Standard: 316 Stainless Steel
  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus
  • UL, CSA, Single Seal, NACE, NEMA 4
830-RA3D-0035-AH0A-C1-B0A5E
830-RA3D-0035-AH0A-C1-B0A5E
KAYDEN® CLASSIC® Thermal Flow & Level Switch, Modbus, In-Line, 3/4" FNPT, 316 SST Sensor with Nickel Braze, Local Electronics Enclosure with Blind Cover, Approvals: C CSA Us (UL Standards)
  • Process Connections: 3/4" FNPT

  • Adjustable Set Point Range: 0-20,000 cc/s

  • Sensor Mounting Orientation: Horizontal

  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz

  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar

  • Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F

  • Local Enclosure: Aluminum Flameproof, 1" FNPT

  • Cover: Flameproof Blind Cover

  • Remote Electronics Enclosure and Cover: Not Selected

  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus

  • ANSI/UL & CSA Approval(s) Pending
  • 830-RA3D-0035-AH0A-C1-B1G-1E
    830-RA3D-0035-AH0A-C1-B1G-1E
    KAYDEN CLASSIC Thermal Flow & Level Switch, Modbus, In-Line, 3/4" FNPT, SST Ni Braze,Remote,Lens,CSA
    830-RA3D-0035-AH0A-C1-B1G1E
    830-RA3D-0035-AH0A-C1-B1G1E
    KAYDEN® CLASSIC® Thermal Flow & Level Switch, Modbus, In-Line, 3/4" FNPT, 316 SST Sensor with Nickel Braze, Remote Electronics Enclosure with Glass Lens Cover, Approvals: C CSA Us (UL Standards)
    • Process Connections: 3/4" FNPT
    • Adjustable Set Point Range: 0-20,000 cc/s
    • Sensor Mounting Orientation: Horizontal
    • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
    • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
    • Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F
    • Local Enclosure: Aluminum Flameproof, 1" FNPT
    • Cover: Flameproof Blind Cover
    • Remote Electronics Enclosure and Cover: Flameproof Glass Cover 
    • Wetted Materials:
      • Standard: 316 Stainless Steel
    • Outputs/Communications:
      • Two Independent Relays (SPDT), 4-20 mA, Modbus
    • UL, CSA, Single Seal, NACE, NEMA 4
    830-RA3D-0035-AH0A-C1-B1G5E
    830-RA3D-0035-AH0A-C1-B1G5E
    KAYDEN® CLASSIC® Thermal Flow & Level Switch, Modbus, In-Line, 3/4" FNPT, 316 SST Sensor with Nickel Braze, Remote Electronics Enclosure with Glass Lens Cover, Approvals: C CSA Us (UL Standards)
    • Process Connections: 3/4" FNPT
    • Adjustable Set Point Range: 0-20,000 cc/s
    • Sensor Mounting Orientation: Horizontal
    • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
    • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
    • Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F
    • Local Enclosure: Aluminum Flameproof, 1" FNPT
    • Cover: Flameproof Blind Cover
    • Remote Electronics Enclosure and Cover: Flameproof Glass Cover 
    • Wetted Materials:
      • Standard: 316 Stainless Steel
    • Outputs/Communications:
      • Two Independent Relays (SPDT), 4-20 mA, Modbus
    • UL, CSA Pending , Single Seal, NACE, NEMA 4
    830-RA3D-0035-AH0A-C1B0A-1E
    830-RA3D-0035-AH0A-C1B0A-1E
    KAYDEN® CLASSIC® Thermal Flow Switch, Modbus, In-Line, 3/4" FNPT, 316 SST Sensor with Nickel Braze, Horizontal Sensor Orientation, Local Electronics Enclosure with Blind Cover, Approvals: C CSA Us (UL Standards)
    830-RA3D-0035-AH0A-C1B0A-5E
    830-RA3D-0035-AH0A-C1B0A-5E
    KAYDEN® CLASSIC® Thermal Flow Switch, Modbus, In-Line, 3/4" FNPT, 316 SST Sensor with Nickel Braze, Horizontal Sensor Orientation, Local Electronics Enclosure with Blind Cover, Approvals: C CSA Us (UL Standards)
    830-RA3D-0035-AH0A-C1B0A-9E
    830-RA3D-0035-AH0A-C1B0A-9E
    KAYDEN® CLASSIC® Thermal Flow Switch, Modbus, In-Line, 3/4" FNPT, 316 SST Sensor with Nickel Braze, Horizontal Sensor Orientation, Local Electronics Enclosure with Blind Cover, Approvals: FM
    830-RA3D-0035-AH0A-C1B1G-1E
    830-RA3D-0035-AH0A-C1B1G-1E
    KAYDEN® CLASSIC® Thermal Flow Switch, Modbus, In-Line, 3/4" FNPT, 316 SST Sensor with Nickel Braze, Horizontal Sensor Orientation, Remote Electronics Enclosure with Glass Lens Cover, Approvals: C CSA Us (UL Standards)
    830-RA3D-0035-AH0AC1B0A9E
    830-RA3D-0035-AH0AC1B0A9E
    KAYDEN® CLASSIC® Thermal Flow & Level Switch, Modbus, In-Line, 3/4" FNPT, 316 SST Sensor with Nickel Braze, Local Electronics Enclosure with Blind Cover, Approvals: FM
    • Process Connections: 3/4" FNPT
    • Adjustable Set Point Range: 0-20,000 cc/s
    • Sensor Mounting Orientation: Horizontal
    • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
    • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
    • Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F
    • Local Enclosure: Aluminum Flameproof, 1" FNPT
    • Cover: Flameproof Blind Cover
    • Remote Electronics Enclosure and Cover: Not Selected
    • Wetted Materials:
      • Standard: 316 Stainless Steel

    • Outputs/Communications:
      • Two Independent Relays (SPDT), 4-20 mA, Modbus

    • FM, NACE, NEMA 4
    1 - 12 of 90 Part Numbers

    Specifications

    Applications

    • Flow

    Principle of Operation

    • Thermal, Calorimetric

    Sensor, Probe Style

    • InLine Threaded

    NPT Connections

    • Two x 3/4" NPT Female

    Sensor Assembly Body Lengths

    • In-Line Body Length is 3.5" (8.8 cm)

    Wetted Materials

    • 316, 316L Stainless Steel with Nickel Brazing

    Bleed Port

    • 1/4" Threaded

    Sensor Orientation

    • Horizontal
    • Vertical

    Injection Tubes - 3/4” Male NPT x 1/4” Female NPT

    • Typical 1, 0.180" Bore, 316 Stainless Steel
    • Typical 2, 0.086" Bore, 316 Stainless Steel
    • Not Required

    Operating Pressure - Sensor

    • Threaded Style: Max.

    Operating Temperature - Sensor

    • -45° to 200° C (-50° to 392° F)

    Operating Temperature - Electronics

    • -55° to 65° C (-67° to 149° F)

    Switch Point Range

    • Air & Gases: 0.6 to 20,000 cc/second Standard Condition: 20° C (70° F) at 14.7 psi (1 Atm)
    • Hydrocarbon-based Liquids: 0.035 to 110 cc/second
    • Water-based Liquids: 0.015 to 50 cc/second

    Response Time

    • Approximately 0.5 to 30 seconds

    Accuracy

    • Flow Service: ± 1.0 % of Set Point over Operating Range of ± 28° C (50° F)

    Switch Type

    • 2 SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.

    Input Power

    • 12-24 Vdc, 120-240 Vac, 50/60 Hz
    • Power Consumption: Max.
    • Universal Power Input

    Output

    • 4-20 mA (Thermal Signal, Scaleable)

    Communication

    • Modbus RTU Communication-Alarms, Flow Status & Diagnostics
    • RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software

    Approvals & Certifications

    • CSA
    • CSA - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Temperature Code: T3 Enclosure Typical 4, IP55 Single Seal Approved per ANSI / ISA 12.27.01-2003
    • CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂) Temperature Code: T3
    • CRN - Canadian Registration Number - the Kayden Classic 830 does not have a CRN Number

    Electronics - Standard Features

    • 100 % Digital Design. Electronics are Environmentally Sealed
    • 4-Adjustable Independent Switch Point Timers
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out*
    • Easy Setup: No Mechanical Jumpers or Trim Pots
    • Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
    • Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
    • Temperature Compensation
    • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode
    • *Configurable only from the Kayden RCM Software

    Remote Control & Monitoring Software

    • Adjust Relay Modes
    • Adjust Set Points 1 & 2
    • Load or Save User Settings
    • Lock or Unlock the Display Panel to Protect the Settings
    • Many Other Adjustable Features
    • Modify Heater Settings to Optimize Response Time
    • Monitor Operating Status
    • Operated Via a Personal Computer Locally or from a Remote Control Center
    • Visualize the Actions of the Process Via the Graphical Display

    Environmental Protection

    • IP55
    • IP67
    • NEMA 4X
    • TYPE 4

    Local Enclosure Conduit Connection

    • 1" NPT Female Conduit Connection

    Local Enclosure & Cover Material

    • Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)

    Local Enclosure Cover

    • Blind Cover - Flameproof
    • Glass Lens Cover - Flameproof
    • Buna-N O-Ring on Cover

    Local Enclosure & Cover Finish

    • Powder-Coated Polyester TGIC

    Remote Electronics Enclosure & Cover

    • Glass Lens Cover - Flameproof

    Remote Electronics Enclosure & Cover Finish

    • Powder-Coated Polyester TGIC

    Storage Temperature

    • Store in a clean & dry environment between -30° & 60° C (-22° & 140° F)

    Flow
    • Pump Protection - Dry Alarm
    • Leak Detection
    • Flow Monitoring & Verification
    • Tank Overflow Protection
    • Flare Gas Monitoring
    • Monitoring Purge Air Flow
    • Lube Oil Systems
    • Vent Monitoring
    • Natural Gas to Boilers
    • Emergency Eye Wash & Shower Stations
    • Drain Line Flow
    • High Pressure Flows
    • Tanker Loading & Unloading
    • Relief Valve & Rupture Disk Flow Monitoring
    • Remote Indication of Flow via Analog Output & Digital Communications
    • Chemical Injection/Additive Flow Monitoring
    Level
    • Storage Tanks
    • Oil Separators & Treaters - High, Low & Interface Level
    • Sumps - All Types of fluids ( Water, Oil, etc. )
    • Free Water Knock-out Tanks - High, Low and Interface Level
    • Leak Detection (Accumulation Reservoir)
    • Tank Overflow
    • Sampler Systems
    • Sand Separators
    Media
    • Liquids, Air & Gases
    • Hazardous & General-Purpose Areas
    • Slurries
    • Corrosive Liquids

    Documentation

    Instantly populate your store or catalog 
    CREATE YOUR SITE
    or book a demo with the Yodify Team
    show more