Brand: Dwyer Instruments, LLCSeries HADP Differential Pressure Transmitter combines low ranges with exceptional stability, reliability and an outstanding accuracy of ±0.14% Full Scale.
All models come with NIST certificates and are available in unidirectional and bi-directional ranges as low as 0 to 0.5 Inches WC and 0 to 5 psid.
The Series HADP transmitters are extremely stable allowing for use in the most demanding applications.
Features- High stability at low pressure ranges provides exceptional accuracy for insuring tight control and minimizing costly out of specification conditions
- Fast warm-up and response means no lag in monitoring and control that can cause time consuming false alarm conditions
1 - 12 of 80 Part Numbers
HADP-BC-08
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 0.25
- Temperature Range - -1° to 65° C (30° to 150° F)
- Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-08-A1
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 0.25
- Temperature Range - -1° to 65° C (30° to 150° F)
- Accuracy - ± 0.073 % Full Scale Accuracy
HADP-BC-08-T1
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 0.25
- Temperature Range - -53° to 121° C (-65° to 250° F)
- Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-08-T1-A1
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 0.25
- Temperature Range - -53° to 121° C (-65° to 250° F)
- Accuracy - ± 0.073 % Full Scale Accuracy
HADP-BC-09
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 0.5
- Temperature Range - -1° to 65° C (30° to 150° F)
- Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-09-A1
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 0.5
- Temperature Range - -1° to 65° C (30° to 150° F)
- Accuracy - ± 0.073 % Full Scale Accuracy
HADP-BC-09-T1
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 0.5
- Temperature Range - -53° to 121° C (-65° to 250° F)
- Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-09-T1-A1
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 0.5
- Temperature Range - -53° to 121° C (-65° to 250° F)
- Accuracy - ± 0.073 % Full Scale Accuracy
HADP-BC-10
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 1
- Temperature Range - -1° to 65° C (30° to 150° F)
- Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-10-A1
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 1
- Temperature Range - -1° to 65° C (30° to 150° F)
- Accuracy - ± 0.073 % Full Scale Accuracy
HADP-BC-10-T1
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 1
- Temperature Range - -53° to 121° C (-65° to 250° F)
- Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-10-T1-A1
- Pressure Type - ± Plus or Minus
- Output - 4-20 mA
- Pressure Range - Inches WC: 0 to ± 1
- Temperature Range - -53° to 121° C (-65° to 250° F)
- Accuracy - ± 0.073 % Full Scale Accuracy
1 - 12 of 80 Part Numbers
Specifications
Brand
Accuracy
- < ± 0.14 % of Full Scale
Applications
- Clean Rooms
- Energy/Water Management
- Environmental Testing
- Leak Detection
- Medical Instruments
Approvals & Certifications
- CE
Compensated Temperature
- -1° to 65° C (30° to 150° F)
Consumption
- < 30 mA
Electrical Connectors
- 2 Foot Cable Standard
Loop Resistance
- Maximum
- Minimum (Vdc) = 17 + 0.02 x Resistance of Receiver Plus Line
Media
- Compatible Non-Conducting Air
- Compatible Non-Conducting Gas
NACE & NIST
- NIST
NPT Connection
- 1/8"-27 Female NPT Internal
Operating Temperature
- -18° to 71° C (0° to 160° F)
Output
- 0-5 Vdc for Voltage Models
- 4-20 mA for Current Models
Power Requirement
- 17-42 Vdc for Current Models
- 22-30 Vdc for Voltage Models
Pressure Range
- bar: 0 to 0.34
- inH₂O: 0 to 15
- kPa: 0 to 34.47
- psid: 0 to 5
Pressure Type
- Differential
Response Time
- < 5 ms
Sensor Orientation
- Pressure Port 90° Parallel to Ground
Span & Zero Effect
- Zero & Span Output: Factory Set to within ± 0.07 mA
Stability
- < ± 0.1 % of Full Scale for 6 Months at 21° C (70° F)
Storage Temperature
- -53° to 121° C (-65° to 250° F)
Temperature Effect
- < ± 1.0 % of Full Scale/38° C (100° F)