Yodify Product Library
Add the Series HADP High Accuracy Differential Pressure Transmitter to your store or catalog  
Book Your Demo and See How
or create your store

Series HADP High Accuracy Differential Pressure Transmitter

Brand: Dwyer Instruments, LLC

Series HADP Differential Pressure Transmitter combines low ranges with exceptional stability, reliability and an outstanding accuracy of ±0.14% Full Scale.

All models come with NIST certificates and are available in unidirectional and bi-directional ranges as low as 0 to 0.5 Inches WC and 0 to 5 psid. 

The Series HADP transmitters are extremely stable allowing for use in the most demanding applications.
Features
  • High stability at low pressure ranges provides exceptional accuracy for insuring tight control and minimizing costly out of specification conditions
  • Fast warm-up and response means no lag in monitoring and control that can cause time consuming false alarm conditions

1 - 12 of 80 Part Numbers
HADP-BC-08
HADP-BC-08
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 0.25
  • Temperature Range - -1° to 65° C (30° to 150° F)
  • Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-08-A1
HADP-BC-08-A1
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 0.25
  • Temperature Range - -1° to 65° C (30° to 150° F)
  • Accuracy - ± 0.073 % Full Scale Accuracy
HADP-BC-08-T1
HADP-BC-08-T1
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 0.25
  • Temperature Range - -53° to 121° C (-65° to 250° F)
  • Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-08-T1-A1
HADP-BC-08-T1-A1
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 0.25
  • Temperature Range - -53° to 121° C (-65° to 250° F)
  • Accuracy - ± 0.073 % Full Scale Accuracy
HADP-BC-09
HADP-BC-09
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 0.5
  • Temperature Range - -1° to 65° C (30° to 150° F)
  • Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-09-A1
HADP-BC-09-A1
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 0.5
  • Temperature Range - -1° to 65° C (30° to 150° F)
  • Accuracy - ± 0.073 % Full Scale Accuracy
HADP-BC-09-T1
HADP-BC-09-T1
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 0.5
  • Temperature Range - -53° to 121° C (-65° to 250° F)
  • Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-09-T1-A1
HADP-BC-09-T1-A1
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 0.5
  • Temperature Range - -53° to 121° C (-65° to 250° F)
  • Accuracy - ± 0.073 % Full Scale Accuracy
HADP-BC-10
HADP-BC-10
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 1
  • Temperature Range - -1° to 65° C (30° to 150° F)
  • Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-10-A1
HADP-BC-10-A1
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 1
  • Temperature Range - -1° to 65° C (30° to 150° F)
  • Accuracy - ± 0.073 % Full Scale Accuracy
HADP-BC-10-T1
HADP-BC-10-T1
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 1
  • Temperature Range - -53° to 121° C (-65° to 250° F)
  • Accuracy - ± 0.14 % Full Scale Accuracy
HADP-BC-10-T1-A1
HADP-BC-10-T1-A1
  • Pressure Type - ± Plus or Minus
  • Output - 4-20 mA
  • Pressure Range - Inches WC: 0 to ± 1
  • Temperature Range - -53° to 121° C (-65° to 250° F)
  • Accuracy - ± 0.073 % Full Scale Accuracy
1 - 12 of 80 Part Numbers

Specifications

Accuracy

  • < ± 0.14 % of Full Scale

Applications

  • Clean Rooms
  • Energy/Water Management
  • Environmental Testing
  • Leak Detection
  • Medical Instruments

Approvals & Certifications

  • CE

Compensated Temperature

  • -1° to 65° C (30° to 150° F)

Consumption

  • < 30 mA

Electrical Connectors

  • 2 Foot Cable Standard

Loop Resistance

  • Maximum
  • Minimum (Vdc) = 17 + 0.02 x Resistance of Receiver Plus Line

Media

  • Compatible Non-Conducting Air
  • Compatible Non-Conducting Gas

NACE & NIST

  • NIST

NPT Connection

  • 1/8"-27 Female NPT Internal

Operating Temperature

  • -18° to 71° C (0° to 160° F)

Output

  • 0-5 Vdc for Voltage Models
  • 4-20 mA for Current Models

Power Requirement

  • 17-42 Vdc for Current Models
  • 22-30 Vdc for Voltage Models

Pressure Range

  • bar: 0 to 0.34
  • inH₂O: 0 to 15
  • kPa: 0 to 34.47
  • psid: 0 to 5

Pressure Type

  • Differential

Response Time

  • < 5 ms

Sensor Orientation

  • Pressure Port 90° Parallel to Ground

Span & Zero Effect

  • Zero & Span Output: Factory Set to within ± 0.07 mA

Stability

  • < ± 0.1 % of Full Scale for 6 Months at 21° C (70° F)

Storage Temperature

  • -53° to 121° C (-65° to 250° F)

Temperature Effect

  • < ± 1.0 % of Full Scale/38° C (100° F)

  • Clean Rooms
  • Energy/Water Management
  • Environmental Testing
  • Leak Detection
  • Medical Instruments
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more