117 Series Type H117 Models 358 to 376 Pressure Switch
Brand: United Electric Controls LtdApproved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.
The rugged, one piece enclosure features a slanted cover for wiring accessibility to the enclosed terminal block that is wired to either a SPDT or DPDT hermetically sealed microswitch. All-welded, stainless steel pressure connections and sensors provide superior corrosion resistance - NACE compliant - and fire-safe protection within the harshest environments.
The 117 Series is an ideal choice for the most demanding applications; typically steel and aluminum mills, chemical and petrochemical plants, pulp and paper mills, wastewater treatment plants, midstream and downstream oil & gas, and pharmaceutical plants.
Features- Epoxy Coated Type 4X Enclosure and Stainless Steel component parts
- Terminal Block Wiring
- Tamper-Resistant Set Point “Lock”
- Approved for Division 2, Zone 2 hazardous locations
- Optional ATEX or GOST intrinsic safety compliance for Zone 0
- Welded Stainless Steel diaphragms meet NACE MR-0175 standard
- Optional sensor material for corrosive media
1 - 12 of 3,888 Part Numbers
H117-358
- Model - 358
- Switch Option - Standard SPDT Switch
- Factory Set Point - No Factory Set Point
- Measurement Range - Standard psi or bar
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - No Mounting Kit
- Cleaning - Without Cleaning
- Electrical Connection - One 1/2” Female NPT & Two 7/8” Diameter Knockouts
H117-358-1190
- Model - 358
- Switch Option - Setting on Rise is Required - Hermetically Sealed, with Gold Flash Contacts, DPDT, 11 A, 125/250 Vac
- Factory Set Point - No Factory Set Point
- Measurement Range - Standard psi or bar
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - No Mounting Kit
- Cleaning - Without Cleaning
- Electrical Connection - One 1/2” Female NPT & Two 7/8” Diameter Knockouts
H117-358-1190-6361-704
- Model - 358
- Switch Option - Setting on Rise is Required - Hermetically Sealed, with Gold Flash Contacts, DPDT, 11 A, 125/250 Vac
- Factory Set Point - No Factory Set Point
- Measurement Range - Standard psi or bar
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - Surface & Pipe Mounting Kit
- Cleaning - Without Cleaning
- Electrical Connection - One 1/2” Female NPT & Two 7/8” Diameter Knockouts
H117-358-1190-6361-704-M550
- Model - 358
- Switch Option - Setting on Rise is Required - Hermetically Sealed, with Gold Flash Contacts, DPDT, 11 A, 125/250 Vac
- Factory Set Point - No Factory Set Point
- Measurement Range - Standard psi or bar
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - Surface & Pipe Mounting Kit
- Cleaning - Oxygen Service Cleaning
- Electrical Connection - One 1/2” Female NPT & Two 7/8” Diameter Knockouts
H117-358-1190-6361-704-M550-SD6286-51
- Model - 358
- Switch Option - Setting on Rise is Required - Hermetically Sealed, with Gold Flash Contacts, DPDT, 11 A, 125/250 Vac
- Factory Set Point - No Factory Set Point
- Measurement Range - Standard psi or bar
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - Surface & Pipe Mounting Kit
- Cleaning - Oxygen Service Cleaning
- Electrical Connection - Converts 7/8” Hole to 1/2” Female NPT Watertight Conduit Fitting
H117-358-1190-6361-704-SD6286-51
- Model - 358
- Switch Option - Setting on Rise is Required - Hermetically Sealed, with Gold Flash Contacts, DPDT, 11 A, 125/250 Vac
- Factory Set Point - No Factory Set Point
- Measurement Range - Standard psi or bar
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - Surface & Pipe Mounting Kit
- Cleaning - Without Cleaning
- Electrical Connection - Converts 7/8” Hole to 1/2” Female NPT Watertight Conduit Fitting
H117-358-1190-M201
- Model - 358
- Switch Option - Setting on Rise is Required - Hermetically Sealed, with Gold Flash Contacts, DPDT, 11 A, 125/250 Vac
- Factory Set Point - Factory Set One Switch
- Measurement Range - Standard psi or bar
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - No Mounting Kit
- Cleaning - Without Cleaning
- Electrical Connection - One 1/2” Female NPT & Two 7/8” Diameter Knockouts
H117-358-1190-M201-6361-704
- Model - 358
- Switch Option - Setting on Rise is Required - Hermetically Sealed, with Gold Flash Contacts, DPDT, 11 A, 125/250 Vac
- Factory Set Point - Factory Set One Switch
- Measurement Range - Standard psi or bar
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - Surface & Pipe Mounting Kit
- Cleaning - Without Cleaning
- Electrical Connection - One 1/2” Female NPT & Two 7/8” Diameter Knockouts
H117-358-1190-M201-6361-704-M550
- Model - 358
- Switch Option - Setting on Rise is Required - Hermetically Sealed, with Gold Flash Contacts, DPDT, 11 A, 125/250 Vac
- Factory Set Point - Factory Set One Switch
- Measurement Range - Standard psi or bar
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - Surface & Pipe Mounting Kit
- Cleaning - Oxygen Service Cleaning
- Electrical Connection - One 1/2” Female NPT & Two 7/8” Diameter Knockouts
H117-358-1190-M201-6361-704-M550-SD6286-51
- Model - 358
- Switch Option - Setting on Rise is Required - Hermetically Sealed, with Gold Flash Contacts, DPDT, 11 A, 125/250 Vac
- Factory Set Point - Factory Set One Switch
- Measurement Range - Standard psi or bar
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - Surface & Pipe Mounting Kit
- Cleaning - Oxygen Service Cleaning
- Electrical Connection - Converts 7/8” Hole to 1/2” Female NPT Watertight Conduit Fitting
H117-358-1190-M201-6361-704-SD6286-51
- Model - 358
- Switch Option - Setting on Rise is Required - Hermetically Sealed, with Gold Flash Contacts, DPDT, 11 A, 125/250 Vac
- Factory Set Point - Factory Set One Switch
- Measurement Range - Standard psi or bar
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - Surface & Pipe Mounting Kit
- Cleaning - Without Cleaning
- Electrical Connection - Converts 7/8” Hole to 1/2” Female NPT Watertight Conduit Fitting
H117-358-1190-M201-M277
- Model - 358
- Switch Option - Setting on Rise is Required - Hermetically Sealed, with Gold Flash Contacts, DPDT, 11 A, 125/250 Vac
- Factory Set Point - Factory Set One Switch
- Measurement Range - kPa or MPa
- Agency Approvals - Without Additional Approvals
- Tag - No Tag
- Mounting - No Mounting Kit
- Cleaning - Without Cleaning
- Electrical Connection - One 1/2” Female NPT & Two 7/8” Diameter Knockouts
1 - 12 of 3,888 Part Numbers
Specifications
Adjustment Type
- Captive Clamp Screws
- Factory Set (Pre-Set)
- Set Point Adjustment
Ambient Temperature Range
- -40° to 71° C (-40° to 160° F)
Applications
- Chemical & Petrochemical
- Midstream & Downstream Oil & Gas
- Pharmaceutical Plants
- Pulp & Paper Mills
- Steel & Aluminum Mills
- Wastewater Treatment Plants
Approvals & Certifications
- ISO 9001
Approvals & Certifications
- ATEX Directive (94/9/EC) II 1 G EEx ia IIC T6 Ga Tamb: -50° to 60° C (-58° to 140° F)
- CE
- CPT 0ExiaIICT6 Tamb: -50° to 60° C (-58° to 140° F)
- CRN
- CSA C22.2 No. 14 & 213 - File # E40857
- GOST-R 51330.0, 51330.1, 51330.10 & 51330.14
- Low Voltage Directive (LVD) 73/23/EC & 93/68/EEC
- PED: 97/23/EC
- UL (C,US) 508 & 1604, Class I, Div. 2, Grade A, B, C, D, Class II, Div. 2, Group F, G, Class III
Conduit Connection
- 1/2” NPT Female
Deadband
- psi: 6 to 28 (kPa: 41.4 to 193.1, bar: 0.4 to 1.9)
- Temperature Deadband: Typically 4 % of Range Under Laboratory Conditions (21.11° C (70° F) Ambient Circulating Bath at Rate of 0.5° F Per Minute Change)
Electrical Connectors
- 1/2” NPT Female
- 7/8” Diameter Knockout
- 7/8” Hole to 1/2” NPT Female Watertight Conduit Fitting
- Common
Electrical Contacts
- Normally Closed
- Normally Open
- Switch Contacts Gold Flashed
Electrical Rating
- 0.5 A at 125 Vdc
- 1 A at 48 Vdc
- 11 A at 125/250 Vac Resistive
- 5 A at 28 Vdc
Enclosure Finish
- Epoxy Powder-Coated
Enclosure, Body Material
- Gasketed Die Cast Aluminum
Environmental Protection
- Intrinsically Safe
- IP66
- NEMA 4X
- NEMA 7
- NEMA 9
Fill Material
- Non-Toxic Oil Filled
Mounting
- Pipe
- Surface
Name Plate, Tag Material
- Anodized Aluminum
- Stainless Steel, Paper ID Tag & Wire Attachment
NPT Connection
- 1/4” NPT Female
Overpressure & Static Pressure Limits
- Over Range Pressure - psi: 200 to 500 (kPa: 1,379 to 3,447, bar: 13.8 to 34.5)
Pressure Type
- Gauge
Process Connection Material
- 316L Stainless Steel
Proof Pressure
- psi: 800 (kPa: 5,516, bar: 55.2)
Repeatability
- Set Point Repeatability: ± 1 % of Adjustable Range
Service
- Oxygen Service Cleaning, Alcohol Cleaning to Remove Residue from the Process Connection
Set Point - Decreasing
- bar: 1 to 34.5
- kPa: 103.4 to 3,447
- psi: 15 to 500
Set Point - Increasing
- bar: 1 to 34.5
- kPa: 103.4 to 3,447
- psi: 15 to 500
Shock
- Set Point Repeats after 15 G, 10 millisecond Duration
Storage Temperature
- -54° to 71° C (-65° to 160° F)
Switch Type
- DPDT
- SPDT
System Pressure
- bar: 13.8 to 137.9
- kPa: 1,379 to 13,790
- psi: 200 to 2,000
Vibration
- Set Point Repeats after 2.5 G, 5 to 500 Hz