Sage 200 thermal flow meters are a cost-effective alternative to the Sage Prime which offers the same level of performance. 

The 200 is manufactured to accommodate our international customers. The flow meter measures gas mass flow and has the same accuracy, repeatability, low-end sensitivity, response time, turndown, and resolution as the Prime without some premium features.

If the user needs to verify that the meter is in calibration, while still in the field and in the pipe, use the Sage Prime, which includes the award-winning Sage In-Situ Calibration Verification. 

Likewise, if a high-contrast graphical display is desired, the Prime will better serve your needs.
Features
  • Measures mass flow
  • Sage meters have the lowest rate of energy loss with a power dissipation of 2.5 watts, making them the most efficient thermal mass flow meter
  • All units come calibrated from the Sage NIST traceable calibration facility and are preconfigured with the specified process and installation parameters for the application
  • The meter has a two-compartment compact housing with a separate wiring section containing large, easy-to-access terminals to simplify field installation.
  • Approved for use in Class I Div 2 hazardous areas and CE approved
  • Available in 24 VDC or 115/230 VAC
  • Isolated 4-20 mA signal and pulse output of the total flow
  • Modbus RTU with RS-485 communication (optional)
  • Available with integral or remote electronics
  • For remote models, lead length compensation permits cable lengths up to 1,000 feet
  • NEMA 4 and explosion-proof junction box
  • For use with a ½” insertion probe in 1″ and larger pipe or in the in-line flow body sizes 1/4″ to 4″
  • Available in blind configuration or display with window providing flow rate, total flow, and gas temperature

1 - 12 of 252 Part Numbers
201-05-06-AC115-AIR
201-05-06-AC115-AIR
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC115
  • Gas Type - Air
  • Mounting Hardware - None
201-05-06-AC115-AIR+STCF05
201-05-06-AC115-AIR+STCF05
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC115
  • Gas Type - Air
  • Mounting Hardware - STCF05 Compression Fitting, <125 psig
201-05-06-AC115-AIR+SVA05
201-05-06-AC115-AIR+SVA05
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC115
  • Gas Type - Air
  • Mounting Hardware - SVA05 Isolation Valve High Pressure, <250 psig
201-05-06-AC115-NG
201-05-06-AC115-NG
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC115
  • Gas Type - Natural Gas
  • Mounting Hardware - None
201-05-06-AC115-NG+STCF05
201-05-06-AC115-NG+STCF05
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC115
  • Gas Type - Natural Gas
  • Mounting Hardware - STCF05 Compression Fitting, <125 psig
201-05-06-AC115-NG+SVA05
201-05-06-AC115-NG+SVA05
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC115
  • Gas Type - Natural Gas
  • Mounting Hardware - SVA05 Isolation Valve High Pressure, <250 psig
201-05-06-AC230-AIR
201-05-06-AC230-AIR
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC230
  • Gas Type - Air
  • Mounting Hardware - None
201-05-06-AC230-AIR+STCF05
201-05-06-AC230-AIR+STCF05
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC230
  • Gas Type - Air
  • Mounting Hardware - STCF05 Compression Fitting, <125 psig
201-05-06-AC230-AIR+SVA05
201-05-06-AC230-AIR+SVA05
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC230
  • Gas Type - Air
  • Mounting Hardware - SVA05 Isolation Valve High Pressure, <250 psig
201-05-06-AC230-NG
201-05-06-AC230-NG
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC230
  • Gas Type - Natural Gas
  • Mounting Hardware - None
201-05-06-AC230-NG+STCF05
201-05-06-AC230-NG+STCF05
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC230
  • Gas Type - Natural Gas
  • Mounting Hardware - STCF05 Compression Fitting, <125 psig
201-05-06-AC230-NG+SVA05
201-05-06-AC230-NG+SVA05
  • Display - Yes
  • Electronics - Integral
  • Probe Size - 1/2"
  • Fittings - STCF50 Compression Fitting
  • Probe Length of Insertion Probes - 6"
  • Power - AC230
  • Gas Type - Natural Gas
  • Mounting Hardware - SVA05 Isolation Valve High Pressure, <250 psig
1 - 12 of 252 Part Numbers

Specifications

Certifications & Approvals

  • CE
  • CSA

Accuracy

  • ± 1 % of Reading Plus 0.5 % of Full Scale

Repeatability

  • 0.2 % of Reading

Sensitivity

  • 5 SFPM (1 scfm in 6″ Pipe)

Response Time

  • 1 s

Resolution

  • 1000:1

Turndown

  • 100:1

Power

  • 24 Vdc
  • 90-265 Vac

Output

  • 4-20 mA

Ambient Temperature

  • -40° to 150° F (-40° to 65° C)

Enclosure Rating

  • NEMA 4

Sensor Type

  • Insertion Probe (1/2” Diameter)
  • Flow Body with Flow Conditioning (1/4” to 4”)

Material of Construction

  • Sensor: 316 Stainless Steel

Process Temperature

  • -40° to 450° F (-40° to 230° C)

Process Pressure

  • Maximum 500 psig

Communication

  • Modbus RTU with RS-485

NIST

  • NIST-traceable Calibration

Media

  • Natural Gas
  • Air

  • Natural gas flow to burners
  • Compressed air flow measurement
  • Combustion air