Yodify Product Library
Instantly add the TT303 Temperature Transmitter and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

TT303 Temperature Transmitter

Brand: Smar International Corp

Features
  • Input Range °C: -200 to 1750
    • Minimum Span °C: 30 to 60
  • Input Range °F: -328 to 3182
    • Minimum Span °F: 86 to 140
  • Power Supply: 12 to 45 Vdc
  • Indicator: 4-1/2 digit numerical and 5-Character alphanumerical LCD indicator
  • Electrical Connection: 1/2"-14 NPT
  • Sensor Type: Thermocouple Type J, K, R, and S - NBS
  • Sensor Connection: 2 to 4-Wire
  • Humidity Limits: 0 to 100% RH
  • Damping Adjustment: User Configurable from 0 to 32 seconds
  • Digital Stability: ±0.1% of reading or 0.1° C (0.18°F)
  • Temperature Effect:
    • mV (-6 to 22 mV), TC (NBS: R & S): ±0.03% of the input millivoltage or 0.002 mV, whichever is greater
    • mV (-10 to 100 mV) TC (NBS: J & K): ±0.03% of the input resistance or 0.01 Ω whichever is greater
  • Power Supply Effect: ± 0.005% of calibrated span per volt
  • Digital Accuracy %:
    • ±0.02% or ± 2 µV
    • ±0.02% or ± 10 µV
  • Minimum Span mV:
    • 0.40 mV
    • 2.00 mV

1 - 12 of 33 Part Numbers
TT303-00-0-I1-L2T4-J0H0P0
TT303-00-0-I1-L2T4-J0H0P0
  • Display - Not Required
  • Mounting - No Mounting Bracket
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - RTD PT100 - IEC
  • Sensor Connection - 2-Wire
  • Identification Plate - FM: XP, IS, NI, DI
TT303-00-0-I1-L2TA-J0H0P0
TT303-00-0-I1-L2TA-J0H0P0
  • Display - Not Required
  • Mounting - No Mounting Bracket
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - Thermocouple Type B - NBS
  • Sensor Connection - 2-Wire
  • Identification Plate - FM: XP, IS, NI, DI
TT303-00-0-I1-L2TD-J0H0P0
TT303-00-0-I1-L2TD-J0H0P0
  • Display - Not Required
  • Mounting - No Mounting Bracket
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - Thermocouple Type K - NBS
  • Sensor Connection - 2-Wire
  • Identification Plate - FM: XP, IS, NI, DI
TT303-00-0-I1-L3T4-J0H0P0
TT303-00-0-I1-L3T4-J0H0P0
  • Display - Not Required
  • Mounting - No Mounting Bracket
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - RTD PT100 - IEC
  • Sensor Connection - 3-Wire
  • Identification Plate - FM: XP, IS, NI, DI
TT303-00-0-I1-L3TA-J0H0P0
TT303-00-0-I1-L3TA-J0H0P0
  • Display - Not Required
  • Mounting - No Mounting Bracket
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - Thermocouple Type B - NBS
  • Sensor Connection - 3-Wire
  • Identification Plate - FM: XP, IS, NI, DI
TT303-00-0-I1-L3TD-J0H0P0
TT303-00-0-I1-L3TD-J0H0P0
  • Display - Not Required
  • Mounting - No Mounting Bracket
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - Thermocouple Type K - NBS
  • Sensor Connection - 3-Wire
  • Identification Plate - FM: XP, IS, NI, DI
TT303-02-0-I1-L2T4-J0H0P0
TT303-02-0-I1-L2T4-J0H0P0
  • Display - Not Required
  • Mounting - 316 Stainless Steel 2" Bracket & Accessories
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - RTD PT100 - IEC
  • Sensor Connection - 2-Wire
  • Identification Plate - FM: XP, IS, NI, DI
TT303-02-0-I1-L2TA-J0H0P0
TT303-02-0-I1-L2TA-J0H0P0
  • Display - Not Required
  • Mounting - 316 Stainless Steel 2" Bracket & Accessories
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - Thermocouple Type B - NBS
  • Sensor Connection - 2-Wire
  • Identification Plate - FM: XP, IS, NI, DI
TT303-02-0-I1-L2TD-J0H0P0
TT303-02-0-I1-L2TD-J0H0P0
  • Display - Not Required
  • Mounting - 316 Stainless Steel 2" Bracket & Accessories
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - Thermocouple Type K - NBS
  • Sensor Connection - 2-Wire
  • Identification Plate - FM: XP, IS, NI, DI
TT303-02-0-I1-L3T4-J0H0P0
TT303-02-0-I1-L3T4-J0H0P0
  • Display - Not Required
  • Mounting - 316 Stainless Steel 2" Bracket & Accessories
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - RTD PT100 - IEC
  • Sensor Connection - 3-Wire
  • Identification Plate - FM: XP, IS, NI, DI
TT303-02-0-I1-L3TA-J0H0P0
TT303-02-0-I1-L3TA-J0H0P0
  • Display - Not Required
  • Mounting - 316 Stainless Steel 2" Bracket & Accessories
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - Thermocouple Type B - NBS
  • Sensor Connection - 3-Wire
  • Identification Plate - FM: XP, IS, NI, DI
TT303-02-0-I1-L3TD-J0H0P0
TT303-02-0-I1-L3TD-J0H0P0
  • Display - Not Required
  • Mounting - 316 Stainless Steel 2" Bracket & Accessories
  • Electrical Connection - 1/2"-14 NPT
  • Sensor Type - Thermocouple Type K - NBS
  • Sensor Connection - 3-Wire
  • Identification Plate - FM: XP, IS, NI, DI
1 - 12 of 33 Part Numbers

Specifications

Accuracy

  • ± 0.2° C (± 0.36° F)
  • ± 0.5° C (± 0.9° F)
  • ± 0.6° C (± 1° F)

Ambient Temperature Range

  • -40° to 85° C (-40° to 185° F)

Approvals & Certifications

  • CEPEL
  • CSA
  • EXAM
  • FM
  • NEMKO ATEX
  • NEPSI

Configuration

  • FOUNDATION Fieldbus & PROFIBUS PA: Basic Configuration May be Done Using the Local Adjustment Magnetic Tool if Device is Supplied with Display. Complete Configuration is Possible Using Configuration Tools Such as Syson, AMS, FieldCare & HHT375.

Control Functions Characteristics

  • PROFIBUS PA Function Blocks: Physical Block, Transducer, Display Transducer & Analog Input

Damping Adjustment

  • User Configurable from 0 to 32 seconds (via Digital Communication).

Digital Stability

  • ± 0.1 % of Reading or +0.1° C (0.18° F), whichever is greater, for 1-Year for Thermocouple
  • ± 0.1 % of Reading or +0.1° C (0.18° F), whichever is greater, for 2-Years for RTDs

Display

  • 4-1/2-Digit LCD Indicator

Electrical Connectors

  • 1/2” NPT
  • M20 x 1.5
  • PG 13.5 DIN

Electromagnetic Interference Effect

  • Approved According to IEC 61326: 2002

Enclosure Finish

  • Gray Munsell 6.5 Polyester Paint

Enclosure, Body Material

  • Aluminum (IP/Type)

Environmental Protection

  • Dust Ignition-Proof
  • Explosion-proof
  • Intrinsically Safe
  • Non-Incendive

Humidity

  • 0 to 100 % Relative Humidity

Input Power

  • FOUNDATION Fieldbus & PROFIBUS PA: Bus Powered 9-32 Vdc, Quiescent Current Consumption 12 mA

Mounting

  • 2” (50 mm) Pipe Mount
  • Directly Attached to the Sensor
  • Panel Mount
  • Wall Mounted

Operating Temperature - Display

  • -20° to 80° C (-4° to 176° F)
  • -40° to 85° C (-40° to 185° F), without Damage

Output

  • Digital Only. Complies with IEC 61158-2: 2000 (H1): 31.25 Kbit/s Voltage Mode, Bus Powered

Power Supply Effect

  • ± 0.005 % of Calibrated Span Per Volt

Sensor, Probe Connection

  • 2-Wire
  • 3-Wire

Span & Zero Adjustments

  • Non-Interactive, Via Local Adjustment & Digital Communication

Storage Temperature

  • -40° to 100° C (-40° to 212° F)

Temperature Effect

  • mV (-10 to 100 mV) TC (NBS: E, J, K, N): ± 0.03 % of the Input mV or 0.01 mV whichever is greater (10° C Variation)
  • mV (-50 to 500 mV): ± 0.03 % of the Input mV or 0.05 mV whichever is greater

Turn-On Time

  • Performs within Specifications in less than 10 seconds after Power is Applied to the Transmitter

Documentation

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more