Yodify Product Library
Instantly add the SP2006-H/DIL & SP2006-H280/DIL Gas Sample Probe and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

SP2006-H/DIL & SP2006-H280/DIL Gas Sample Probe

Brand: M&C TechGroup Germany GmbH

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. 

Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. 

The M&C dilution probe SP2006-H/DIL is based on the well tested M&C gas sample probe SP2000-H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.
Features
  • Based on probe SP2000-H
  • Electrically heated up to 180° C or 280° C
  • NEMA 4, FRP housing
  • External heated critical orifice with additional safety filter
  • Including a dilution gas pre-heater
  • No dew point problems
  • Dilution ratios from 10:1 up to 500:1
  • With check gas connection
  • Independent of the process temperature
  • Changing of dilution and bypass block without any tools within a few minutes
  • No disconnection of any tubes or hoses for changing of dilution or bypass block
  • Easy operation and maintenance

1 - 12 of 45 Part Numbers
20S4402 (A)
20S4402 (A)
  • Version - Dilution Probe 180° C (356° F) with Second Sample Outlet
  • Panel - Without
20S4402 (A) 20S4250
20S4402 (A) 20S4250
  • Version - Dilution Probe 180° C (356° F) with Second Sample Outlet
  • Panel - SP2000H/DIL-S: Control Panel with 1 Pressure Controller, 2 Gauges, Flowmeter, 2 Ball Valves
20S4402 (A) 20S4260
20S4402 (A) 20S4260
  • Version - Dilution Probe 180° C (356° F) with Second Sample Outlet
  • Panel - SP2000H/DIL-S1: Control Panel with 2 Pressure Controller, 3 Gauges, Flowmeter, 2 Ball Valves
20S4423 (A)
20S4423 (A)
  • Version - Dilution Probe 180° C (356° F) with Bypass Injector, Bypass Gas to the Vent & Second Sample Outlet
  • Panel - Without
20S4423 (A) 20S4250
20S4423 (A) 20S4250
  • Version - Dilution Probe 180° C (356° F) with Bypass Injector, Bypass Gas to the Vent & Second Sample Outlet
  • Panel - SP2000H/DIL-S: Control Panel with 1 Pressure Controller, 2 Gauges, Flowmeter, 2 Ball Valves
20S4423 (A) 20S4260
20S4423 (A) 20S4260
  • Version - Dilution Probe 180° C (356° F) with Bypass Injector, Bypass Gas to the Vent & Second Sample Outlet
  • Panel - SP2000H/DIL-S1: Control Panel with 2 Pressure Controller, 3 Gauges, Flowmeter, 2 Ball Valves
20S4424 (A)
20S4424 (A)
  • Version - Dilution Probe 180° C (356° F) with Bypass Injector, Bypass Gas Recirculation & Second Sample Outlet
  • Panel - Without
20S4424 (A) 20S4250
20S4424 (A) 20S4250
  • Version - Dilution Probe 180° C (356° F) with Bypass Injector, Bypass Gas Recirculation & Second Sample Outlet
  • Panel - SP2000H/DIL-S: Control Panel with 1 Pressure Controller, 2 Gauges, Flowmeter, 2 Ball Valves
20S4424 (A) 20S4260
20S4424 (A) 20S4260
  • Version - Dilution Probe 180° C (356° F) with Bypass Injector, Bypass Gas Recirculation & Second Sample Outlet
  • Panel - SP2000H/DIL-S1: Control Panel with 2 Pressure Controller, 3 Gauges, Flowmeter, 2 Ball Valves
SP2006-H/DIL
SP2006-H/DIL
  • Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
  • Panel - Without
SP2006-H/DIL 20S4250
SP2006-H/DIL 20S4250
  • Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
  • Panel - SP2000H/DIL-S: Control Panel with 1 Pressure Controller, 2 Gauges, Flowmeter, 2 Ball Valves
SP2006-H/DIL 20S4260
SP2006-H/DIL 20S4260
  • Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
  • Panel - SP2000H/DIL-S1: Control Panel with 2 Pressure Controller, 3 Gauges, Flowmeter, 2 Ball Valves
1 - 12 of 45 Part Numbers

Specifications

Environmental Protection

  • NEMA 4

Flow Rate

  • Bypass Injector / B: Gas Pressure-Gas Flow Rate-Sample Gas Flow Rate at Approximately psig: 29.01 (kPa: 200, bar: 2) Injector Gas Approximately 300 L/hr
  • Bypass Injector / B: Gas Pressure-Gas Flow Rate-Sample Gas Flow Rate at Approximately psig: 29.01 (kPa: 200, bar: 2) Sample Gas Approximately 150 L/hr
  • Dilution Gas Flow Rate with Injector Version I: 480 to 600 NL/hr
  • Dilution Gas Flow Rate with Injector Version II: Higher Dilution Rates 1,800 to 3,000 NL/hr

Materials of Construction

  • Materials in Contact with the Sample Gas: 316Ti Stainless Steel
  • Materials in Contact with the Sample Gas: FPM
  • Materials in Contact with the Sample Gas: Graphite
  • Materials in Contact with the Sample Gas: Quartz Glass

Mounting

  • Rack-Mounted

Operating Pressure

  • psia: 13.05 to 29.01 (kPa: 90 to 200, bar: 0.9 to 2)

Pressure Range

  • Dilution Gas Pressure on Inlet of Pressure Controller - psig: 65.27 to 232.1 (kPa: 450 to 1,600, bar: 4.5 to 16)

Ratio

  • Dilution - 10:1 to 500:1

Temperature Range

  • Electrically Heated: 0° to 280° C (32° to 536° F)
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more