Yodify Product Library
Instantly add the Bus-Carrier Series 9419 and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Bus-Carrier Series 9419

Brand: R. STAHL AG

9419 series bus carriers allow 9412 series fieldbus power supplies for FF H1 segments to be installed quickly and securely. Variants are available for eight segments with simplex supply and for four or eight segments with redundant supply. Pluggable terminals are used to connect the fieldbus segments and host assemblies.
Features
  • Time- and cost-saving installation on DIN rails or mounting plates
  • High availability thanks to redundant auxiliary power supply with signaling contact and separate signaling contact for segment errors
  • Special slot for 9415 series DCM for online transmission of physical layer diagnostics

1 - 3 of 3 Part Numbers
208745
208745
R. STAHL ISbus Fieldbus Technology Bus-Carrier
Time- and cost-saving installation on DIN rails or mounting plates

High availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors

Special slot for 9415 series DCM for online transmission of physical layer diagnostics

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - < 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C

Auxiliary power

  • Nominal voltage - 24 V DC
  • Redundant supply - yes, diode-decoupled

Electrical Data

  • Error detection Diagnostic - Contact "Dia" (35 V /100 mA) closed in good conditions
  • Error detection Power Fail (pri / red) - Contact "PF" (35 V /100 mA) closed in good conditions
  • Number of segments - 8
  • Trunk supply - simplex

Explosion Protection

  • Application range (zones) - 2
  • ATEX gas certificate - BVS 09 ATEX E 100 X
  • Certificate EAC - TS RU S-DE.GB04.B.00081
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), EAC (Sertium), IECEx (BVS), India (PESO), USA (FM)
  • Gas explosion protection ATEX - II 3 G Ex nA nC IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA nC IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA nC IIC T4 Gc
  • IECEX gas certificate - IECEx BVS 09.0042X

General

  • Description - bus-Carrier for 8 segments, simplex
  • Functional Description - 9419 series bus carriers allow 9412 series fieldbus power supplies for FF H1 segments to be installed quickly and securely. Variants are available for eight segments with simplex supply and for four or eight segments with redundant supply. Pluggable terminals are used to connect the fieldbus segments and host assemblies.
  • Highlights - Time- and cost-saving installation on DIN rails or mounting plates High availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors Special slot for 9415 series DCM for online transmission of physical layer diagnostics
  • Product Description - ISbus fieldbus technology Bus-Carrier
  • Product Type - 9419/08F-XX1-01C1
  • Product Variant - bus-Carrier
  • Title Product Variant Technical Data - 9419/08F-XX1-01C1 8SEG bus-carrier
  • WebCode - 9419A

Mechanical Data

  • Connection DCM - via ribbon cable using plug connectors
  • Connection Host / red. host - to the terminals of the bus-Carrier or of the Fieldbus Power Supplies
  • Connection Shield - via integrated shield bar with strain relief
  • Connection Trunk - to the terminals of the bus-Carrier or of the fieldbus power supply
  • Degree of protection IP (IEC 60529) - IP00
  • Number of slots - 8 FPS + 1 DCM
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.600 kg

Mounting / Installation

  • Connection - To any FF H1 host
208746
208746
R. STAHL ISbus Fieldbus Technology Bus-Carrier
Time- and cost-saving installation on DIN rails or mounting plates

High availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors

Special slot for 9415 series DCM for online transmission of physical layer diagnostics

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - < 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C

Auxiliary power

  • Nominal voltage - 24 V DC
  • Redundant supply - yes, diode-decoupled

Electrical Data

  • Error detection Diagnostic - Contact "Dia" (35 V /100 mA) closed in good conditions
  • Error detection Power Fail (pri / red) - Contact "PF" (35 V /100 mA) closed in good conditions
  • Number of segments - 4
  • Trunk supply - redundant

Explosion Protection

  • Application range (zones) - 2
  • ATEX gas certificate - BVS 09 ATEX E 100 X
  • Certificate EAC - TS RU S-DE.GB04.B.00081
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), EAC (Sertium), IECEx (BVS), India (PESO), USA (FM)
  • Gas explosion protection ATEX - II 3 G Ex nA nC IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA nC IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA nC IIC T4 Gc
  • IECEX gas certificate - IECEx BVS 09.0042X

General

  • Description - bus-Carrier for 4 segments, redundant
  • Functional Description - 9419 series bus carriers allow 9412 series fieldbus power supplies for FF H1 segments to be installed quickly and securely. Variants are available for eight segments with simplex supply and for four or eight segments with redundant supply. Pluggable terminals are used to connect the fieldbus segments and host assemblies.
  • Highlights - Time- and cost-saving installation on DIN rails or mounting plates High availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors Special slot for 9415 series DCM for online transmission of physical layer diagnostics
  • Product Description - ISbus fieldbus technology Bus-Carrier
  • Product Type - 9419/04R-XX1-02C1
  • Product Variant - bus-Carrier
  • Title Product Variant Technical Data - 9419/04R-XX1-02C1 4SEG bus-carrier
  • WebCode - 9419A

Mechanical Data

  • Connection DCM - via ribbon cable using plug connectors
  • Connection Host / red. host - to the terminals of the bus-Carrier or of the Fieldbus Power Supplies
  • Connection Shield - via integrated shield bar with strain relief
  • Connection Trunk - to the terminals of the bus-Carrier or of the fieldbus power supply
  • Degree of protection IP (IEC 60529) - IP00
  • Number of slots - 8 FPS + 1 DCM
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.600 kg

Mounting / Installation

  • Connection - To any FF H1 host
208747
208747
R. STAHL ISbus Fieldbus Technology Bus-Carrier
Time- and cost-saving installation on DIN rails or mounting plates

High availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors

Special slot for 9415 series DCM for online transmission of physical layer diagnostics

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C
  • Ambient temperature max. - +70 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - < 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C

Auxiliary power

  • Nominal voltage - 24 V DC
  • Redundant supply - yes, diode-decoupled

Electrical Data

  • Error detection Diagnostic - Contact "Dia" (35 V /100 mA) closed in good conditions
  • Error detection Power Fail (pri / red) - Contact "PF" (35 V /100 mA) closed in good conditions
  • Number of segments - 8
  • Trunk supply - redundant

Explosion Protection

  • Application range (zones) - 2
  • ATEX gas certificate - BVS 09 ATEX E 100 X
  • Certificate EAC - TS RU S-DE.GB04.B.00081
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), EAC (Sertium), IECEx (BVS), India (PESO), USA (FM)
  • Gas explosion protection ATEX - II 3 G Ex nA nC IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA nC IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA nC IIC T4 Gc
  • IECEX gas certificate - IECEx BVS 09.0042X

General

  • Description - bus-Carrier for 8 segments, redundant
  • Functional Description - 9419 series bus carriers allow 9412 series fieldbus power supplies for FF H1 segments to be installed quickly and securely. Variants are available for eight segments with simplex supply and for four or eight segments with redundant supply. Pluggable terminals are used to connect the fieldbus segments and host assemblies.
  • Highlights - Time- and cost-saving installation on DIN rails or mounting plates High availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors Special slot for 9415 series DCM for online transmission of physical layer diagnostics
  • Product Description - ISbus fieldbus technology Bus-Carrier
  • Product Type - 9419/08R-XX1-02C1
  • Product Variant - bus-Carrier
  • Title Product Variant Technical Data - 9419/08R-XX1-02C1 8SEG bus-carrier
  • WebCode - 9419A

Mechanical Data

  • Connection DCM - via ribbon cable using plug connectors
  • Connection Host / red. host - to the terminals of the bus-Carrier or of the Fieldbus Power Supplies
  • Connection Shield - via integrated shield bar with strain relief
  • Connection Trunk - to the terminals of the bus-Carrier or of the fieldbus power supply
  • Degree of protection IP (IEC 60529) - IP00
  • Number of slots - 16 FPS + 1 DCM
  • Terminal degree of protection (IP) - IP20
  • Weight - 1.200 kg