The FN3060 S-beam load cell is highly suited for use in test benches and fatigue tests. 

Due to the mechanical design, the FN3060 is especially durable. High-level output models with integrated A1/A2 amplifier are available. Sensor can all be supplied in higher temperature range for fatigue tests in oven.
Features
  • High stiffness
  • Accuracy : 0.1% F.S. 
  • Integrated Amplifier optional 
  • IP 64 protected

Specifications

Accuracy

  • < ± 0.1 % of Full Scale - Combined Non-Linearity & Hysteresis

Applications

  • Dynamic Fatigue Testing
  • Laboratory & Research
  • Lifetime Test Benches
  • Pneumatic Cylinder Monitoring
  • Robotics & Effectors

Approvals & Certifications

  • CE
  • EN 50081-1
  • EN 50082-1
  • EN 61010-1

Cable Length

  • 6.56 feet (2 metres)

Compensated Temperature

  • 0° to 60° C (32° to 140° F)

Consumption

  • < 50 mA
  • 50 mA

Enclosure, Body Material

  • Aluminum Alloy

Environmental Protection

  • IP64

Input Impedance

  • 350 to 700 ohms

Insulation Resistance

  • ≥ 100 megaohms

Load Impedance

  • < 100 ohms - Output Impedance
  • 1,000 ohms - Output Impedance
  • 350 to 700 ohms - Output Impedance

Operating Temperature

  • -20° to 80° C (-4° to 176° F)

Sensitivity

  • < 1 % of Reading / 50° C (100° F) - Sensitivity Shift
  • ± 2 mV/V of Full Scale Output
  • ± 2 V ± 0.2 V of Full Scale Output
  • ± 5 V ± 0.2 V of Full Scale Output

Supply Voltage

  • ± 15 Vdc (± 12 to ± 18 Vdc)
  • 10 Vdc
  • 10-30 Vdc

Thermal Drift

  • < 0.5 % of Full Scale/50° C (100° F)

Zero Offset

  • < ± 5 % of Full Scale
  • 0 V, ± 0.2 V