Yodify Product Library
Instantly add the AX433 Dual Channel Transmitter for 4-Electrode Conductivity Cell and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
AX433 Dual Channel Transmitter for 4-Electrode Conductivity Cell
Brand: ABB GroupThe AX433 conductivity transmitter enables two continuous measurements of mS/cm conductivity with simultaneous local display and transmission via analog outputs.
The transmitter is designed for use with ABB’s 4-electrode conductivity cells to measure with exceptional accuracy and performance.
It incorporates the latest technology to provide a highly reliable, flexible, feature-packed device that satisfies a diverse range of process monitoring and control applications.
Features- Cost effective
- select one or two conductivity inputs or combine pH/Redox (ORP) with conductivity in one analyzer
- Advanced measuring capabilities
- conductivity range up to 1,999 mS cm-1
- selectable concentration ranges:
- 0 to 15% NaOH, 0 to 18% HCl, 0 to 20% H2SO4
- 0 to 40% H3PO4, 0 to 20% NaCl and user-defined
- Dosing control functionality
- long dose diagnostic alarm
- initial charge function
- Reduced installation cost
- easy access terminations; reduced panel space
- High functionality at minimum cost
- three alarms and two fully-isolated current outputs
- direct linear, reverse acting or bi-linear output
- Expanded monitoring and control
- add-on option board provides a total of five alarm relays and four current outputs
- service logbook providing historical data
- Reduced yearly maintenance costs
- 12 to 30 Vdc option negates the need for costly safety tests
1 - 12 of 48 Part Numbers
AX43310001
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43310002
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43310003
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43310101
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 12 to 30 Vdc
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43310102
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 12 to 30 Vdc
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43310103
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 12 to 30 Vdc
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43311001
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43311002
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43311003
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43311101
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 12 to 30 Vdc
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43311102
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 12 to 30 Vdc
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX43311103
- First Process Variable (PV1) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Second Process Variable (PV2) - Conductivity 0 to 1,999 mS cm-1 for 4-Electrode Sensors
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 12 to 30 Vdc
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
1 - 12 of 48 Part Numbers
Specifications
Brand
Range
- 0 to 2,000 mS/cm
- Concentration: Uup to 15 % NaOH, 18 % HCl, 20 % H₂SO4 or NaCl, or 40 % H3PO4
Environmental Protection
- NEMA 4X
- IP66
Temperature Sensor
- Pt1000 or 3k Balco
Display
- Dual 5-digit, 7-segment backlit LCD
Accuracy
- Analog output: ± 0.25 % FSD, ± 0.5 % of Reading, whichever is greater
- Conductivity: ± 0.5 % measurement Range per decade
Resolution
- 0.1 % at 10 mA , 0.05 % at 20 mA
Communication
- PROFIBUS DP
Mounting
- Panel Mounting
- Pipe Mounting
- Wall Mounting
Power Supply
- 85-265 Vac
- 12-30 Vdc
Power Consumption
- 10 W
Certifications & Approvals
- EMC
- CE
- UL
Operating Temperature
- -20° to 55° C (-4° to 131° F)
Storage Temperature
- -25° to 75° C (13° to 167° F)
Humidity
- Up to 95 % Relative Humidity Non-Condensing
- Regeneration of Ion Exchangers
- Municipal Water Phosphoric Acid Control
- Food & Beverage Product / Water Interface Detection
- Clean-in-Place Concentration Monitoring
Documentation
Brochure
Certificate
Manual
- Instruction - AX4xx and AV4xx series transmitters | Display driver selection | LCD display module (AX400/0295) pdf 1.7 MB
- Manual - AX413, AX430, AX433, AX436 and AX438 Single and Dual Input Analyzers for High-level Conductivity pdf 1.2 MB
- Manual - User guide supplement - AX400 series | Single and dual input analyzers | PROFIBUS® datalink description pdf 602 KB