Ethernet CPU Module & Power Module for Zone 2 / Div. 2 Series 9441/15

Brand: R. STAHL AG

The 9441/12 series CPU for Zone 2 is used to communicate with the automation system via PROFINET, Modbus TCP or Ethernet/IP. 

The connection is established by means of an optically inherently safe "op is" fibre optic, which can be connected and disconnected in hazardous areas. IS1+ and connected HART devices are integrated into asset management systems using a DTM.
Features
  • Suitable for "op is" 100 Mbit/s Ethernet with PROFINET, Modbus TCP or Ethernet/IP
  • redundant activation with Modbus TCP possible
  • CPU can be hot swapped in Zone 2

1 - 1 of 1 Part Numbers
211046
211046
R. STAHL Remote I/O IS1 Ethernet CPU Module
Suitable for "op is" 100 Mbit/s Ethernet with PROFINET, Modbus TCP or Ethernet/IP

redundant activation with Modbus TCP possible

CPU can be hot swapped in Zone 2

Ambient Conditions

  • Ambient temperature - -20 °C ... +65 °C
  • Ambient temperature max. - +65 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95%
  • Storage temperature - -20 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -20 °C

Auxiliary power

  • Nominal voltage - 24 V DC

Electrical Data

  • Connection Ethernet Interface - LC
  • Ethernet protocols - EtherNet/I, Modbus TCP, PROFINET
  • Ethernet transmission distance - ≤ 2000 m
  • Ethernet transmission speed - ≤ 100 Mbps
  • Field side of interfaces - 100BASE-FX op ist
  • Protocols - EtherNet/I, Modbus TCP, PROFINET
  • Redundancy - Modbus TCP

Explosion Protection

  • Application range (zones) - 2, 21, 22
  • ATEX dust certificate - KEMA 10 ATEX 0118 X
  • ATEX gas certificate - IECEx KEM 10.0051X
  • Certificate EAC - TS RU S-DE.AA71.B.00033
  • Certificates - ATEX (DEK), Brazil (ULB), Canada (FM), EAC (STV), IECEx (DEK), USA (FM)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] [Ex op is Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] [Ex op is Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] [Ex op is Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 2
  • Ex interface zone - 2, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA d [ia Ga] [op is T6 Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA d [ia Ga] [op is T6 Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA d [ia Ga] [op is T6 Ga] IIC T4 Gc
  • IECEX dust certificate - KEMA 10 ATEX 0118 X
  • IECEX gas certificate - IECEx KEM 10.0051X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - ABS, CCS, ClassNK, DNVGL, RINA

General

  • Functional Description - The 9441/12 series CPU for Zone 2 is used to communicate with the automation system via PROFINET, Modbus TCP or Ethernet/IP. The connection is established by means of an optically inherently safe "op is" fibre optic, which can be connected and disconnected in hazardous areas. IS1+ and connected HART devices are integrated into asset management systems using a DTM.
  • Highlights - Suitable for "op is" 100 Mbit/s Ethernet with PROFINET, Modbus TCP or Ethernet/IP redundant activation with Modbus TCP possible CPU can be hot swapped in Zone 2
  • Product Description - Remote I/O IS1 Ethernet CPU Module
  • Product Type - 9441/15-00-00
  • Title Product Variant Technical Data - 9441/15-00-00 CPU+ Z2
  • WebCode - 9441B

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP30
  • Height - 172.000 mm
  • Length - 125.000 mm
  • Weight - 1.300 kg
  • Width - 340.000 mm
1 - 1 of 1 Part Numbers