Ethernet CPU Module & Power Module for Zone 2 / Div. 2 Series 9441/15
Brand: R. STAHL AGThe 9441/12 series CPU for Zone 2 is used to communicate with the automation system via PROFINET, Modbus TCP or Ethernet/IP.
The connection is established by means of an optically inherently safe "op is" fibre optic, which can be connected and disconnected in hazardous areas. IS1+ and connected HART devices are integrated into asset management systems using a DTM.
Features- Suitable for "op is" 100 Mbit/s Ethernet with PROFINET, Modbus TCP or Ethernet/IP
- redundant activation with Modbus TCP possible
- CPU can be hot swapped in Zone 2
1 - 1 of 1 Part Numbers
211046
Suitable for "op is" 100 Mbit/s Ethernet with PROFINET, Modbus TCP or Ethernet/IP
redundant activation with Modbus TCP possible
CPU can be hot swapped in Zone 2
Ambient Conditions
- Ambient temperature - -20 °C ... +65 °C
- Ambient temperature max. - +65 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95%
- Storage temperature - -20 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -20 °C
Auxiliary power
- Nominal voltage - 24 V DC
Electrical Data
- Connection Ethernet Interface - LC
- Ethernet protocols - EtherNet/I, Modbus TCP, PROFINET
- Ethernet transmission distance - ≤ 2000 m
- Ethernet transmission speed - ≤ 100 Mbps
- Field side of interfaces - 100BASE-FX op ist
- Protocols - EtherNet/I, Modbus TCP, PROFINET
- Redundancy - Modbus TCP
Explosion Protection
- Application range (zones) - 2, 21, 22
- ATEX dust certificate - KEMA 10 ATEX 0118 X
- ATEX gas certificate - IECEx KEM 10.0051X
- Certificate EAC - TS RU S-DE.AA71.B.00033
- Certificates - ATEX (DEK), Brazil (ULB), Canada (FM), EAC (STV), IECEx (DEK), USA (FM)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] [Ex op is Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] [Ex op is Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] [Ex op is Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 2
- Ex interface zone - 2, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA d [ia Ga] [op is T6 Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA d [ia Ga] [op is T6 Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA d [ia Ga] [op is T6 Ga] IIC T4 Gc
- IECEX dust certificate - KEMA 10 ATEX 0118 X
- IECEX gas certificate - IECEx KEM 10.0051X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - ABS, CCS, ClassNK, DNVGL, RINA
General
- Functional Description - The 9441/12 series CPU for Zone 2 is used to communicate with the automation system via PROFINET, Modbus TCP or Ethernet/IP. The connection is established by means of an optically inherently safe "op is" fibre optic, which can be connected and disconnected in hazardous areas. IS1+ and connected HART devices are integrated into asset management systems using a DTM.
- Highlights - Suitable for "op is" 100 Mbit/s Ethernet with PROFINET, Modbus TCP or Ethernet/IP redundant activation with Modbus TCP possible CPU can be hot swapped in Zone 2
- Product Description - Remote I/O IS1 Ethernet CPU Module
- Product Type - 9441/15-00-00
- Title Product Variant Technical Data - 9441/15-00-00 CPU+ Z2
- WebCode - 9441B
Mechanical Data
- Degree of protection IP (IEC 60529) - IP30
- Height - 172.000 mm
- Length - 125.000 mm
- Weight - 1.300 kg
- Width - 340.000 mm