Yodify Product Library
Instantly add the UFM 610 P Ultrasonic Flowmeter - Portable Device and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
UFM 610 P Ultrasonic Flowmeter - Portable Device
Brand: KrohneThe UFM 610 P is a portable flowmeter designed for use on liquid flows in full pipes, which utilise “Clamp-On” Transducers.
Easy to use with rugged packaging, the UFM 610 P features a large easy to read Graphics Display with backlighting.
A simple FAST TRACK set up procedure; Simple to follow keypad; IP65 Instrument case with IP65 rated sockets; Guide rail assembly including magnets (if required) for steel pipes above 3-1/2” (89 mm) diameter.
Advantages of measuring from the outside
- Non-contact measurement
- No construction of the pipe cross-section
- No additional pressure drop
- No interruption of the process
- Electrical conductivity, pressure, density, etc. have no effect on measurements
- Easy to install
- No maintenance requirement
- Low power consumption
- Low operating costs
- 112k memory logger
- RS232 output
- Pulse output
- 4-20 mA or 0-20 mA output
- 24 hours battery (rechargeable)
- Self checking facilities
- Battery management
- Continuous signal monitoring
Specifications
Brand
Ambient Temperature Range
- -25° to 60° C (-13° to 140° F)
Applications
- Acids
- Alkaline Solutions
- Boiler Feedwater in Power Stations
- Checking Other Flowmeters
- Demineralized Water for Cooling Purposes
- Oil
- Pretreated Wastewater in Sewage Plants
Approvals & Certifications
- CE to EN 50081-1 & EN 50082-1
- TÜV
Cable Length
- Sensor Cable: 10 feet (3 metres)
Consumption
- Power: 9 VA
Display
- Backlit
Electrical Connectors
- Coaxial Cable RG 174 with LEMO Connectors
- Plug Connection (5-Pin, 9-Pin)
Enclosure, Body Material
- Carrying Case: Hard Plastic
- Sensor Housing: PEEK (Polyetheretherketone)
Environmental Protection
- IP65
- IP66
- NEMA 4
- NEMA 4X
Interface Connection
- RS-232
Load
- 1 Kiloohm for Pulse Output
Materials of Construction
- Mounting Device: Anodized Aluminum
- Pipeline: Metal
- Pipeline: Plastic
Measuring Error
- ± 0.066 Foot/second (± 0.02 m/sec) - for V < 3.3 feet/sec (1 m/sec)
- ± 2 % of Measured Value - for V ≥ 3.3 feet/sec (1 m/sec)
Media
- Liquids
Output
- 0 to 16 mA
- 0-20 mA
- 1 Pulse/second
- 100 Pulses/second
- 4-20 mA
Output Format
- Current Output
- Pulse Output
Power Supply
- 15 V from Signal Converter
- 90-257 Vac, 50/60 Hz
Pulse Range
- Pulse Width: 100 milliseconds
- Pulse Width: 5 milliseconds
Repeatability
- ± 0.5 % of Measured Value
Sensor, Probe Connection
- Lemo Connector
Sensor, Probe Style
- Ultrasonic
Temperature Range
- -20° to 200° C (-4° to 392° F)
Time Constant
- 3 to 100 seconds
- Demineralized water for cooling purposes
- Boiler feedwater in power stations
- Pretreated wastewater in sewage plants
- Checking other flowmeters
- Oil
- Acids
- Alkaline solutions