Yodify Product Library
Instantly add the Model XLK Shackle Assembly Load Cell and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Model XLK Shackle Assembly Load Cell

Brand: Tecsis

By incorporating the load sensing capability into the legs of the shackle instead of in the pin, the sensor is always in the proper orientation for best results, even with a swinging or shifting load. 

Combining the outputs from the two sensing elements also provides exceptional repeatability. 

The unit is built to survive in harsh industrial environments, and the hermetic construction conforms to IP67 for water resistance. 

The unit is available with internal or in-line amplification to provide 4-20 mA (2- or 3-wire), 0-5 Vdc, or 0-10 Vdc output. 

A variety of electrical connections are also offered. 

This product is protected by US Design Patent D703,907S.
Features
  • Set of spherical washers available as an option
  • Cable with mating connector available as an option
  • High resistance bridge available as an option

1 - 2 of 2 Part Numbers
XLK-01K
XLK-01K
  • Capacity - 1,000 lbs
XLK-020K
XLK-020K
  • Capacity - 20,000 lbs
1 - 2 of 2 Part Numbers

Specifications

Brand

Approvals & Certifications

  • TÜV: 2005-08-11 / tecsis
  • CE
  • EN
  • ISO 9001: 2015 Certified
  • SIL 3 Certification

Compensated Temperature

  • 15° to 71° C (60° to 160° F)

Consumption

  • Power Consumption: 100 mW

Electrical Connectors

  • M12 x 1, 4-Pin

Electrical Protection

  • Overload Protection
  • Reverse Current Polarity
  • Short Circuit Protected

Enclosure, Body Material

  • Force Transducers & Amplifier Housing: Stainless Steel

Environmental Protection

  • IP67

Excitation Voltage

  • 15 Vdc
  • 5 Vdc

Hysteresis

  • ± 0.15 % of Full Scale Output, Combined

Insulation Resistance

  • > 5 GigaOhms / 50 V
  • 1 Megaohm

Linearity

  • ± 0.15 % of Full Scale Output, Combined

Load

  • Safe Overload: 400 % of Capacity
  • Using Load: 150 %

Load Limit

  • Breaking Load: > 300 %

Measuring Error

  • ± 0.5 % of Full Scale
  • Combined Error: ± 0.15 % of Full Scale

Measuring Range

  • 0 to 20,000 lbs

Operating Temperature

  • -46° to 121° C (-50° to 250° F)

Output

  • 0-10 Vdc
  • 0-5 Vdc
  • 4-20 mA, 2 & 3-Wire

Power Supply

  • 12-40 Vdc

Repeatability

  • ± 0.15 % of Full Scale Output, Combined

Resistance

  • Bridge Resistance: 700 ohms Nominal

Service Temperature

  • -45° to 120° C (-49° to 248° F)

Span & Zero Effect

  • ≤ ± 0.1 % of Full Scale/10K
  • ≤ ± 0.2 % of Full Scale/10K
  • Span Effect: ± 0.02 % of Reading/°F
  • Zero Effect: ± 0.05 % of Full Scale Output/°F

Temperature Range

  • Nominal 15° to 70° C (59° to 158° F)

Zero Balance

  • ± 1 % of Full Scale Output
  • ± 2 % of Full Scale Output

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more