Baseline 9000 Methane/Non-Methane Analyzer

Brand: MOCON

The Baseline® 9000 Methane / Non-Methane Analyzer uses a flame ionization detector (FID) in conjunction with an oxidation catalyst switched in and out of the sample stream.

The catalyst oxidizes all hydrocarbons except methane to produce a methane only measurement. This catalytic reaction relies on the presence of oxygen (O₂) in the sample.

The methane value is then subtracted from the total hydrocarbon concentration to determine the non-methane hydrocarbon reading. Output options include analog, digital and logic capabilities.

Our methane and non-methane analyzer provides fast data handling and highly reproducible results.

Errors commonly associated with catalyst characteristics have been eliminated providing an extremely stable and accurate signal.

Because the non-methane signal is the difference in the two measured quantities, it is more stable, thus greatly reducing its systemic zero drift.

The non-methane signal response factor is adjusted and thus closely correlates to the carbon number. This analytic method eliminates integration errors that can be present in gas chromatographic (GC) methods.

The Baseline® 9000 Methane / Non-Methane Analyzer can be configured with internal components for single or multi-point analysis of non-condensing gas samples.

The automatic calibration feature enhances the long-term analytical stability of the instrument.

The instrument provides access to operating parameters and concentration data through an RS-232 or Ethernet port. A simple ASCII, tab delimited protocol has been implemented.

The ASCII data can be acquired by an external PC running a basic communications program such as Windows® Hyper Terminal or the analyzer can output binary or ASCII formats directly to a data acquisition system or PLC.

Every Baseline® 9000 analyzer includes AMETEK MOCON's free PC utility 9000 Keeper used for storing and uploading multiple methods, as well as sending configuration settings, directly to the analyzer.
Features
  • Automated Control
    • FlowGuard control of fuel, air, and sample with automatic shut-off
    • Automatic FID ignition
    • Electronic back-pressure regulator with sample bypass system
    • Automatic calibration at user-defined intervals
    • Automatic adjustment for catalyst efficiency variance
    • For cleanroom, environmental, and process applications
    • Provides methane, non-methane, and total hydrocarbon concentrations
  • Versatile Platform
    • Graphic LCD display with easy to use menu
    • Benchtop or rack-mountable
    • Single or multi-point sampling
    • Customizable ethernet or serial output
    • Programmable analog output ranges
    • Programmable relays for diagnostics, concentration, alarms, and events

Specifications

Brand

Detector

  • Flame Ionization (FID) with Oxidizer

Ranges

  • User Definable Based Upon Calibration (as Methane):
  • Ambient Version: Low - 0.03 ppm to 50 ppm | Medium - 0.06 ppm to 500 ppm | High - 0.15 ppm to 5000 ppm
  • 120° C Version: Low - 0.06 ppm to 50 ppm | Medium - 0.6 ppm to 500 ppm | High - 1.0 ppm to 5000 ppm

Accuracy, Repeatability

  • ± 1 % Full Scale

Drift, Zero

  • ± 0.01 % Full Scale, 24 hours

Drift, Span

  • ± 1 % Full Scale, 24 hours

Response Time

  • T90 < 30 seconds

Sampling

  • Internal Single Point, Pump Optional

Alarms

  • Multilevel Concentration and Fault Alarms, Audible and Visual

Calibration

  • Programmable Automatic or Manual Calibration

Support Gas Requirement

  • Support Gas Requirement UHP Hydrogen (H₂) - 35 cc/min
  • Span Gas - Methane/Propane is Typical
  • Zero Air - 175 cc/min
  • Fuel Blend Options Available

Display

  • Graphical LCD, 3.4” x 4.5” (8.64 cm x 11.43 cm)

Outputs, Standard

  • RS-232
  • LAN/Ethernet
  • Analog, 1 Programmable 0-20 mA/4-20 mA Isolated Output
  • Relays, 5 Programmable Form A Relays Rated to 3A @ 230 Vac

Outputs, Optional

  • 3 Additional Analog Outputs
  • 5 Additional Relays

Operating Temperature

  • 32° to 104° F (0° to 40° C)

Operating Humidity

  • 0 to 95 % (Non-Condensing)

Configuration

  • Benchtop or 19” (48.3 cm) Rack-Mount, 3U

Accessories

  • Preventive Maintenance Kit - Includes all parts potentially needed on-hand
  • Gas Generators - Hydrogen generators, Zero Air generators
  • Software - 9000 Keeper provided for method switching
  • Service & Support Options - Start-up and training, 1 day onsite

Dimension & Weight

  • 5.25” H x 19” W x 16.25” D (13.02 cm x 48.26 cm x 41.28 cm), < 20 lbs (9.07 kg)

Electrical Requirements

  • Voltage: 100-240 Vac 50/60 Hz, 1 A

  • Environmental Monitoring
    • AMC in Cleanrooms
    • Air Quality Monitoring
    • Fugitive Emission Monitoring
  • Toxic Gas Monitoring
    • Indoor Air Quality
    • Leak Detection
    • OEM PID Sensors
  • Industrial Process Analysis & Control
    • Beverage Gas Monitoring
    • Industrial Gas Mixing Control
    • Process Gas Analysis
    • Specialty and Industrial Gas Monitoring
    • Surface Logging Analysis