Specifications
Brand
Head Loss % of Differential (Venturi)
- 3.50 to 10.0 percent
Basic Accuracy (% of Total)
- ± 0.25 (Calibrated) ± 0.50 (2 Sigma) (Uncalibrated)
Minimum Pipe Reynolds Number
- Must be greater than 75,000
Required Straight Piping
- Consult datasheet for required US & DS piping based on your specific application
Beta Range
- 0.30 through 0.75
Useful Service Life
- Very Long
Service Functional Limits
- Clear liquid, gas, contaminated and solid-bearing line fluid