9113B-EMP Temperature / mA Converter, EMPHASIS Assessed

Brand: PR Electronics

  • Input for RTD, TC and mA
  • Active / passive mA output via the same two terminals
  • 1 or 2 channels
  • EMPHASIS assessed instrument for nuclear industry
  • SIL 2-certified via Full Assessment
Features
  • Configuration and monitoring by way of detachable display front (PR 4500); process calibration and signal simulation.
  • Copying of the configuration from one device to others of the same type via the display front.
  • TC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 / PR 5913Ex, channel 2) for higher accuracy.
  • Advanced monitoring of internal communication and stored data.
  • SIL 2 functionality is optional and must be activated in a menu point.
  • 1 green and 2 red front LEDs indicate operation status and malfunction.
  • 2.6 kVAC galvanic isolation between input, output and supply.
  • Can be supplied separately or installed on power rail, PR type 9400.

1 - 2 of 2 Part Numbers
9113BA-EMP
9113BA-EMP
  • Channels - Signal
9113BB-EMP
9113BB-EMP
  • Channels - Double
1 - 2 of 2 Part Numbers

Specifications

Approvals & Certifications

  • ATEX KEMA 07ATEX0148 X
  • EAC TR-CU 020/2011
  • RoHS 2011/65/EU
  • LVD 2014/35/EU
  • EMC 2014/30/EU
  • SIL 2 Certified & Fully Assessed acc. to IEC 61508
  • ClassNK TA18527M
  • DNV Marine TAA00000JD
  • EAC Ex RU C-DK.HA65.B.00355/19
  • cULus, UL 61010-1 E314307
  • INMETRO DEKRA 16.0003 X
  • cFMus FM19US0059X / FM19CA0032X
  • IECEx KEM 09.0052X

Environmental Protection

  • IP20

Humidity

  • < 95 % Relative Humidity, Non-Condensing

Operating Temperature

  • -20° to 60° C

Storage Temperature

  • -20° to 85° C

Calibration Temperature

  • 20° to 28° C

Vibration

  • ± 1 mm at 2 to 13.2 Hz
  • ± 0.7 g at 13.2 to 100 Hz

Mounting

  • DIN Rail

Supply Voltage

  • 19.2-31.2 Vdc

Response Time

  • 0.4 to 60 s

RTD Type

  • Pt10/20/50/100/200/250/300/P t400/500/1000, Ni50/100/120/1000

Output Signal

  • Signal Range: 0-23 mA
  • Programmable Signal: 0-20/4-20/20-0/20-4 mA

  • The device can be mounted in the safe area and in zone 2 / cl. 1 div. 2 and receive signals from zone 0, 1, 2 and zone 20, 21, 22 including M1 / Class I/II/III, Div. 1, Gr. A-G.
  • Conversion and scaling of temperature (Pt, Ni and TC) and active current signals.
  • The 9113B-EMP has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
  • Suitable for the use in systems up to Performance Level “d” according to ISO-13849.