Features
  • Sample logging to internal memory
  • Bluetooth® connection to PC
  • Low or high gas contenctration alarm thresholds
  • Large display showing Oxygen & Carbon Dioxide in real time
  • Accurate, rapid response Zirconia O₂ sensor: 1ppm to 100%
  • NDIR CO₂ sensor, 0 to 100%
  • Annual re-calibration
  • 4x field programmable output relays
  • 2x fully isolated range programmable 4-20mA outputs
  • Live monitoring via Bluetooth®

1 - 3 of 3 Part Numbers
1637-1
1637-1
NOVATECH Measurement: Oxygen - Pump: Yes
1637-2
1637-2
NOVATECH Measurement: Oxygen - Pump: No
1637-5
1637-5
NOVATECH Measurement: Oxygen & CO₂ - Pump: Yes
1 - 3 of 3 Part Numbers

Specifications

Accessories

  • Metal can piercing tool
  • Filters for Particulate and moisture
  • Septum
  • Hypodermic needles for plastic packs

Oxygen Range

  • 1 ppm to 100 %

Oxygen Response Time

  • < 4 seconds with gas flow of 100cc per minute

Oxygen Accuracy

  • ± 0.5 % Repeatability measured value
  • ± 1 % of actual measured value

Oxygen Display Resolution

  • 0.1 to 99.9 ppm ± 0.1 ppm
  • 100 to 10,000 ppm ± 1 ppm
  • 1.00 to 29.99 %: ± 0.01 %
  • 30.0 to 100 % ± 0.1 %

CO₂ Range

  • 0 to 100 %

CO₂ Response Time

  • < 8 seconds with gas flow of 100cc per minute

CO₂ Accuracy

  • 80 to 100 % ± 5 %
  • 0 to 40 % ± 2 %
  • 40 to 80 % ± 3 %

Gas Connection

  • 1/8” Swagelok Tube Connection

Communications

  • BlueTooth

Analog Outputs (Available Only in Continuous Sampling Mode)

  • Four user Programmable Alarm Relays
  • Two Isolated, linearized 4-20 mA DC, 1000 ohm max

Alarm Relays (Available Only in Continuous Sampling Mode)

  • 2 A/240 Vac, 2 A/30 Vdc
  • 4 Isolated Programmable, failsafe (Active Open)

Mains Voltage Supply

  • 85 to 265 Vac (50/60 Hz)

Mains Power

  • 500 W Max. Instantaneous
  • 115 W Continuous

Warm Up Time

  • 5 Minutes

Environmental Rating

  • Relative Humidity: 5 % to 95 % (Non-Condensing)
  • With CO₂: 0 to 45° C (32 to 110° F)
  • Without CO₂: 0 to 50° C (32 to 120° F)

Dimensions

  • 265 x 150 x 350 mm (10.5” x 6” x 13.75”)

Weight

  • 6 kg (13.2 lbs)

Mounting

  • Desktop

  • Head-space analysis in closed packages
  • Head-space analysis in cans
  • Inert and sterile packaging
  • Continuous process measurement