Yodify Product Library
Instantly add the GM700 In-Situ Gas Analyzer and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
GM700 In-Situ Gas Analyzer
Brand: Sick AGHigh reliability and precision as well as minimal response times are the distinguishing features of the GM700 laser gas analyzer.
Based on the principle of TDLS (Tunable Diode Laser Spectroscopy) and by using specific light absorption, the GM700 is able to measure several gas components, such as NH3, HF, HCl or H2O.
The in-situ measurement is ideal for the fast determination of gas concentrations in process control and emission monitoring.
Features- In-situ measurement directly in the process for accurate measured values
- Measuring probe or cross-duct types to match the requirements of your measuring task perfectly
- High reliability during operation
- Can also be used in harsh ambient conditions
- Detects quick and short-term process fluctuations
Specifications
Brand
Certifications & Approvals
- CE
- ATEX
Enclosure Rating
- IP66
- IP65
Communication
- CAN Bus
- PROFIBUS DP
- Serial
Measuring Range
- Certified: HF 0 to 5 mg/m³ / 0 to 25 mg/m³
- Dual Measuring: NH₃ / H₂O 0 to 25 ppm / 0 to 100 ppm (NH₃), 0 to 40 Vol. % / 0 to 40 Vol. % (H₂O)
- Dual Measuring: NH₃ / H₂O 0 to 25 ppm / 0 to 4,000 ppm (NH₃), 0 to 20 Vol. % / 0 to 20 Vol. % (H₂O)
- Dual Measuring: HCl / H₂O 0 to 10 ppm / 0 to 3,000 ppm (HCl), 0 to 50 Vol. % / 0 to 100 Vol. % (H₂O)
- HF: 0 to 5 ppm / 0 to 2,000 ppm
- HCl: 0 to 10 ppm / 0 to 3,000 ppm
- NH₃ (up to 40 % H₂O by Volume) 0 to 25 ppm / 0 to 100 ppm
- NH₃ (up to 20 % H₂O by Volume) 0 to 25 ppm / 0 to 4,000 ppm
Response Time
- HF measurement 1 to 180 s, Adjustable, Preset to 4 s, Suitability-tested According to EN 15267
- Standard 1 to 360 s, Adjustable, Preset to 4 s
Accuracy
- GMP: 1 %
- ≤ ± 2 %
Ambient Temperature
- -20° to 50° C
Storage Temperature
- -40° to 55° C
Humidity
- Ambient: ≤ 95 % Relative Humidity, Non-Condensing
Mounting
- Mounting Flange, DN 125, PN 6
- Mounting Flange, ANSI, 5″
Documentation
Data Sheets
Product Manuals
- Additional Information For Analyzers, Measuring Devices And Traffic Sensors According To EN IEC 61010-1:2011 pdf 908 KB
- GM700 Cross-Duct Version - Protection Window for NH3 and HF addendum to operating instructions pdf 907 KB
- GM700 Ex, Cross-Duct Version Operating Instructions pdf 8.3 MB
- GM700 Ex, Measuring Probe Version Operating Instructions pdf 8.3 MB
- GM700 Probe Version - Protection Window For Nh3 And Hf Addendum To Operating Instructions pdf 814 KB
- GM700, Cross-Duct Version Operating Instructions pdf 9.9 MB
- Laser Gas Analyzer, Probe Version Operating Instructions pdf 8.0 MB
- Safety Information For Non-Ex Analyzers pdf 2.8 MB
- SLV4 - Purge Air Unit Operating Instructions pdf 1.2 MB