Yodify Product Library
Instantly add the AV410 Dissolved Organics Monitor and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
AV410 Dissolved Organics Monitor
Brand: ABB GroupAV410 single-channel UV254 low-level dissolved organics monitors (0 to 20 mg-1C) are designed for use on potable water treatment plants.
In particular, they can be used to monitor the quality of the outlet from sand and carbon filters to provide a THM precursor measurement.
Long term field trials have shown that maintenance demands on these applications are minimal.
Features- Dual input gives two measurements in one instrument, each input can be either high range or low range
- cost-effective
- Surrogate color measurement
- significant savings on operational costs through lower maintenance requirements
- Savings on alum or ferric are achieved on potable water treatment plants
- coagulation control cost saving
- Less alum, less sludge
- reduced sludge disposal costs
- THM (trihalomethanes) precursor alert
- provides advanced warning of increased risk of THM development
- Automatic compensation for turbidity
- reduces initial capital expenditure, minimizing operational costs
- Reagentless operation
- significant savings in operational expenditure
- On-line diagnostics
- cleaner failure, loss of signal, out of sample
1 - 12 of 48 Part Numbers
AV410/10001
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - None
- Power Supply - 100 to 240 Vac, 50/60 Hz
- Manual - English
- Wall - IP65 General - Wall-Mount
AV410/10002
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - None
- Power Supply - 100 to 240 Vac, 50/60 Hz
- Manual - French
- Wall - IP65 General - Wall-Mount
AV410/10003
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - None
- Power Supply - 100 to 240 Vac, 50/60 Hz
- Manual - Italian
- Wall - IP65 General - Wall-Mount
AV410/10101
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - None
- Power Supply - 12 to 30 Vdc
- Manual - English
- Wall - IP65 General - Wall-Mount
AV410/10102
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - None
- Power Supply - 12 to 30 Vdc
- Manual - French
- Wall - IP65 General - Wall-Mount
AV410/10103
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - None
- Power Supply - 12 to 30 Vdc
- Manual - Italian
- Wall - IP65 General - Wall-Mount
AV410/12001
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - PROFIBUS (Pending)
- Power Supply - 100 to 240 Vac, 50/60 Hz
- Manual - English
- Wall - IP65 General - Wall-Mount
AV410/12002
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - PROFIBUS (Pending)
- Power Supply - 100 to 240 Vac, 50/60 Hz
- Manual - French
- Wall - IP65 General - Wall-Mount
AV410/12003
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - PROFIBUS (Pending)
- Power Supply - 100 to 240 Vac, 50/60 Hz
- Manual - Italian
- Wall - IP65 General - Wall-Mount
AV410/12101
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - PROFIBUS (Pending)
- Power Supply - 12 to 30 Vdc
- Manual - English
- Wall - IP65 General - Wall-Mount
AV410/12102
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - PROFIBUS (Pending)
- Power Supply - 12 to 30 Vdc
- Manual - French
- Wall - IP65 General - Wall-Mount
AV410/12103
- Parameter 1 - Low Range Dissolved Organics
- Parameter 2 - None
- Transmitter Enclosure Type - Wall - IP65 General
- Serial Communication - PROFIBUS (Pending)
- Power Supply - 12 to 30 Vdc
- Manual - Italian
- Wall - IP65 General - Wall-Mount
1 - 12 of 48 Part Numbers
Specifications
Brand
Range
- 0 to 20 mgl-1 C
Linearity
- ± 2 % of Reading or 0.15 mgl-1 C whichever is greater
Reproductivity
- ± 0.15 mgl-1 C
Sample Temperature
- 0° to 40° C (32° to 104° F)
Sample Pressure
- 3 bar (43.5 psi) Max.
Flow Rate
- Sample: 0.5 to 5 L/min-1
Display
- Dual 4-1/2-digit, 7-segment backlit LCD
Resolution
- Low Range: ± 0.01 mgl-1 C
- Output: 0.1 % at 10 mA, 0.05 at 20 mA
Accuracy
- ± 0.25 % FSD ± 5 % of Reading
Output
- 0 to 10 mA, 0 to 20 mA or 4 to 20 mA
Power Supply
- Optional 12-30 Vdc
- 100-240 Vac, 50/60 Hz (90-264 V)
Power Consumption
- 20 W
Environmental Protection
- IP65
Cable Type
- N. American 7 x knockouts suitable for 1/2 in. Hubble Gland
- Standard 5 or 7 x M20 cable Glands
Operating Temperature
- 0° to 50° C (32° to 122° F)
Storage Temperature
- -25° to 75° C (-13° to 167° F)
Humidity
- Up to 95 % Relative Humidity, Non-Condensing
Certifications & Approvals
- UL
- CE
- EMC
- Potable Water Treatment
Documentation
Manual
- Instruction - AX4xx and AV4xx series transmitters | Display driver selection | LCD display module (AX400/0295) pdf 1.7 MB
- Version matrix - AV400 pdf 15 KB
- AV410, AV411, AV412, AV420 and AV422 Single and Dual Input Dissolved Organics Monitor pdf 1.3 MB
- UV Dissolved Organics and UV Nitrate Monitors AV400 Series pdf 1.2 MB