Yodify Product Library
Instantly add the Model PGT43HP.100, PGT43HP.160 Diaphragm Pressure Gauge with Output Signal and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Model PGT43HP.100, PGT43HP.160 Diaphragm Pressure Gauge with Output Signal

Brand: WIKA Alexander Wiegand SE & Co. KG

Wherever the process pressure has to be indicated locally and, at the same time, a signal transmission to the central control or remote centre is desired, the model PGT43HP intelliGAUGE® (patent, property right: e.g. DE 202007019025) can be used.

 Due to the metallic pressure element limit stop, these instruments have a high overload safety in the ranges of 40, 100 and 400 bar.
Features
  • No configuration necessary due to "Plug-and-Play".
  • Measuring ranges from 0 ... 16 mbar.
  • Wide choice of special materials.
  • For gaseous, liquid and aggressive media, also in aggressive ambience, due to all stainless steel construction.
  • Safety pressure gauge S3 per EN 837.

Specifications

Nominal Size in mm

  • 100
  • 160

Accuracy Class

  • 1.0
  • 1.6

Scale Ranges

  • Or all other equivalent vacuum or combined pressure and vacuum ranges
  • other units (e.g. psi, kPa) available
  • 0 to 400 mbar to 0 to 40 bar (Flange Ø 100 mm)
  • 0 to 16 mbar to 0 to 250 mbar (Flange Ø 160 mm)

Scale

  • Dual Scale
  • Single scale

Pressure Limitation

  • Fluctuating: 0.9 x Full Scale Value
  • Steady: Full Scale Value

Overload Safety

  • Vacuum safety to -1 bar
  • 100 bar
  • 40 bar
  • 400 bar (Only for scale Ranges ≥ 0 ... 400 mbar 3))

Process Connection with Lower Measuring Flange

  • and other threaded Connections and open Connecting Flanges per EN/ASME from DN 15 to DN 80 (See data sheet IN 00.10)
  • Open Connecting Flange 2” Class 300, RF per ASME B16.5
  • Open Connecting Flange 1” Class 300, RF per ASME B16.5
  • Open Connecting Flange DN 50 PN 40 per EN 1092-1, Form B
  • Open Connecting Flange DN 25 PN 40 per EN 1092-1, Form B
  • 1/2” NPT Female
  • 1/2” NPT
  • G 1/2 B

Permissible Temperature

  • Ambient:  -20° to +60° C [-4° to +140° F]
  • Medium:  +200° C [+392° F] Max.
  • Medium: +100° C [+212° F] Max.

Temperature Effect

  • When the temperature of the measuring system deviates from the reference temperature (+20° C): Max. ± 0.8 %/10 K of Full Scale Value

Case

  • Safety version S3 per EN 837: with solid baffle wall (Solidfront) and blow-out back instruments with liquid filling with compensating valve to vent case

Case Filling

  • Without
  • With Silicone oil M50 Case filling, ingress Protection IP65

  • Acquisition and display of processes
  • Output signals 4 ... 20 mA, 0 ... 20 mA, 0 ... 10 V for the transmission of process values to the control room
  • For measuring points with increased overload of 40, 100 or 400 bar
  • Easy-to-read, analogue on-site display needing no external power
  • Safety-related applications
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more