Yodify Product Library
Add the Model PGT43HP.100, PGT43HP.160 Diaphragm Pressure Gauge with Output Signal to your store or catalog  
Book Your Demo and See How
or create your store

Model PGT43HP.100, PGT43HP.160 Diaphragm Pressure Gauge with Output Signal

Brand: WIKA Alexander Wiegand SE & Co. KG

Wherever the process pressure has to be indicated locally and, at the same time, a signal transmission to the central control or remote centre is desired, the model PGT43HP intelliGAUGE® (patent, property right: e.g. DE 202007019025) can be used.

 Due to the metallic pressure element limit stop, these instruments have a high overload safety in the ranges of 40, 100 and 400 bar.
Features
  • No configuration necessary due to "Plug-and-Play".
  • Measuring ranges from 0 ... 16 mbar.
  • Wide choice of special materials.
  • For gaseous, liquid and aggressive media, also in aggressive ambience, due to all stainless steel construction.
  • Safety pressure gauge S3 per EN 837.

Specifications

Nominal Size in mm

  • 100
  • 160

Accuracy Class

  • 1.0
  • 1.6

Scale Ranges

  • Or all other equivalent vacuum or combined pressure and vacuum ranges
  • other units (e.g. psi, kPa) available
  • 0 to 400 mbar to 0 to 40 bar (Flange Ø 100 mm)
  • 0 to 16 mbar to 0 to 250 mbar (Flange Ø 160 mm)

Scale

  • Dual Scale
  • Single scale

Pressure Limitation

  • Fluctuating: 0.9 x Full Scale Value
  • Steady: Full Scale Value

Overload Safety

  • Vacuum safety to -1 bar
  • 100 bar
  • 40 bar
  • 400 bar (Only for scale Ranges ≥ 0 to 400 mbar 3))

Process Connection with Lower Measuring Flange

  • and other threaded Connections and open Connecting Flanges per EN/ASME from DN 15 to DN 80 (See data sheet IN 00.10)
  • Open Connecting Flange 2" Class 300, RF per ASME B16.5
  • Open Connecting Flange 1" Class 300, RF per ASME B16.5
  • Open Connecting Flange DN 50 PN 40 per EN 1092-1, Form B
  • Open Connecting Flange DN 25 PN 40 per EN 1092-1, Form B
  • 1/2" NPT Female
  • 1/2" NPT
  • G 1/2 B

Permissible Temperature

  • Ambient:  -20° to +60° C [-4° to +140° F]
  • Medium:  +200° C [+392° F] Max.
  • Medium: +100° C [+212° F] Max.

Temperature Effect

  • When the temperature of the measuring system deviates from the reference temperature (+20° C): Max. ± 0.8 %/10 K of Full Scale Value

Case

  • Safety version S3 per EN 837: with solid baffle wall (Solidfront) and blow-out back instruments with liquid filling with compensating valve to vent case

Case Filling

  • Without
  • With Silicone oil M50 Case filling, ingress Protection IP65

  • Acquisition and display of processes
  • Output signals 4 ... 20 mA, 0 ... 20 mA, 0 ... 10 V for the transmission of process values to the control room
  • For measuring points with increased overload of 40, 100 or 400 bar
  • Easy-to-read, analogue on-site display needing no external power
  • Safety-related applications