905 Hand-Held Combustion Analyser
Brand: Kane International Limited
Features
- Measures Temperature, Pressure, O₂ and CO as standard
- Stores 150 sets of test results
- Output to IR Printer (optional)
OPTIONS
- (CO and any two other sensors)
- High range CO sensor
- Low range NO sensor
- High range NO sensor
- NO₂ sensor SO₂ sensor
- Wireless upgrade (2.1)
- Teflon hose
Specifications
Ambient Operating Range
- -5° to +50° C / 10 % to 90 % RH, Non-Condensing
Battery Life
- > 8 Hours from Full Charge
Gas Measurement Accuracy
- Carbon Dioxide: ± 0.3 % of Reading
- Carbon Monoxide (H₂ Compensated), Carbon Monoxide: ± 20 ppm 400 ppm
- Carbon Monoxide: ± 10 % > 5000 ppm
- Carbon Monoxide: ± 5 % 100 ppm
- Oxygen, Excess Air: ± 0.2 %
- Poison Index: ± 0.01
- Pressure: ± 0.5 % of Full Scale
- Sulphur Dioxide (Optional): +5 % > 100 ppm
- Temp (Nett): ± 2° C ± 0.3 % of Reading
Gas Measurement Range
- Carbon Dioxide, Losses, Efficiency: 0 - 99.9 %
- Carbon Monoxide (H₂ Compensated): 0 - 4000 ppm
- Carbon Monoxide: 0 - 100000 ppm
- CO / CO₂ Ratio: 0 - 0.9999
- Excess Air: 0 - 2885.0 %
- Nitric Oxide (Low Range): 0 - 100 ppm
- Nitric Oxide & Sulphur Dioxide (Optional): 0 - 5000 ppm
- Nitrogen Dioxide (Optional): 100 ppm
- Oxygen: - 25 %
- Poison Index: 0 - 99.99
- Pressure: 150 Mbar
- Temp (Nett): 0° C - 1200° C / 32° to 2200° F
Gas Measurement Resolution
- Carbon Monoxide (H₂ Compensated), Carbon Monoxide, Nitric Oxide (Low Range & Optional), Nitrogen Dioxide & Sulphur Dioxide (Optional): 1 ppm
- CO / CO₂ Ratio: 0.0001
- Oxygen, Carbon Dioxide, Losses, Efficiency, Excess Air: 0.1 %
- Poison Index: 0.01 %
- Pressure: 0.1 Mbar
- Temperature (Nett): 1.0° C/F
Power Supply (Battery Charger)
- Input: 110 VAC/220 VAC Nominal
- Output: 12 VAC Off Load
Pre-Programmed Fuels
- Natural Gas, Town Gas, Gascor, Light Oil, Heavy Oil, Propane, Butane, Anthracite, Coke, Coal, Kinsale Gas
Sensor, Probe
- Length 240 mm x Diameter 8 mm with 285 mm Long Stainless Steel Shaft, Typical K Thermocouple & 1.5 m Long Neoprene Hose
Temperature Measurement Accuracy
- Flue Temperature: ± 2.0° C ± 0.3 % of Reading
- Inlet Temperature: ± 1° C ± 0.3 % of Reading
Temperature Measurement Range
- Flue Temperature: 0° to 1200° C / 32° to 2200° F with Suitable Probe
- Inlet Temperature: 0° to 50° C / 32° to 122° F
Temperature Measurement Resolution
- Flue Temperature, Inlet Temperature: 0.1° C/F