GW53 Guided Wave Radar Level Instrument

Brand: BM Technologies

GW53 for liquids Applications: Level measurement of liquids, suitable for those with dielectric low constant, in critical environments. 

The microwaves impulses at high frequency travel through a stainless steel guide and they are reflected on the surface of the fluid to analyze. 

The period of time that passes between the emission of the impulses and their reception is proportional to the distance between the surface of the fluid and the plan of reference of the instrument. 

BM COMPACT GW53 series is supplied with the advanced microprocessor echo discovery, it can be used in very different environmental conditions.

1 - 1 of 1 Part Numbers
GW53
GW53
  • Type of Detecting Component / Material - Coaxial Pole Ø 28 mm / AISI 316L Stainless Steel
  • Process Connection - Thread G 1-1/2" A
  • Retained Seal / Operating Temperature - Viton / -30° to 150° C
  • Electronics - 4-20 mA / 198-242 Vac / HART (4-Wires)
  • Housing Material / Protection Class - Plastic / IP66
  • Wiring - M20 x 1.5
  • Display / Programming - YES
1 - 1 of 1 Part Numbers

Specifications

Accuracy

  • ± 10 mm

Applications

  • Level Measurement of Liquid & Solid

BSP Connection

  • Antenna: G 1-1/2” A
  • G 2” A

Cable Entry

  • 1 x PG 13.5

Communication

  • Output Signal: HART

Consumption

  • Absorption: Max.

Current

  • Fixed Signal for Anomaly: 20.5 mA
  • Fixed Signal for Anomaly: 22 mA
  • Fixed Signal for Anomaly: 3.6 mA

Display

  • Resolution Display: 0.039” (1 mm)

Electrical Connectors

  • 1/2” NPT
  • M20 x 1.5

Enclosure, Body Material

  • AISI 316L Stainless Steel
  • Aluminum
  • Plastic PBT-FR

Environmental Protection

  • IP66
  • IP67

Frequency

  • 100 to 10,000 Hz
  • Resistance to Vibration: 10 to 150 Hz

Humidity

  • < 95 % Relative Humidity

Input

  • Input Voltage: 15-36 Vdc for Supply 2-Wires Version
  • Input Voltage: 230 Vac ± 10 % for Supply 4-Wires Version
  • Input Voltage: 24 Vdc ± 10 % for Supply 4-Wires Version

Materials of Construction

  • Pole: AISI 316L Stainless Steel

Measuring Range

  • Maximum

Measuring Time

  • Interval of Measuring: Approximately 1 second

NPT Connection

  • Antenna: 1-1/2” NPT Male

Operating Temperature

  • -40° to 250° C (-40° to 482° F)

Output

  • 4-20 mA, 2 or 4-Wires

Pressure Range

  • bar: -1 to 40
  • kPa: -100 to 4,000
  • psi: -14.5 to 580

Resistance

  • Maximum

Resolution

  • 6 µA

Seat / Seal Material

  • Seal: Kalrez
  • Seal: Viton

Storage Temperature

  • -40° to 80° C (-40° to 176° F)

Update Time

  • Integration Time: 0 to 999 seconds
  • Interval of Updating: Approximately 1 second