Yodify Product Library
Add the Model M80XP Methane Monitor to your store or catalog  
Book Your Demo and See How
or create your store

Model M80XP Methane Monitor

Brand: Envent Engineering Ltd

The M80XP infrared gas sensor has been designed for easy integration into a wide range of gas detection systems where high quality, long term stability, excellent repeatability and reliable measurement of Methane gas concentrations are required. 

These features can be attributed to a proprietary dual wavelength, fail to safe, infrared (NDIR) sensor technology. 

The M80XP provides solutions for measuring and analyzing both industrial and environmental gases.
Features
  • Class I, Division 1
  • Dual-Beam NDIR Technology
  • Long-term stability
  • Low power consumption (2 watts)
  • Dual alarm outputs
  • 4-20 mA output
  • RS-232 and RS-485 Modbus communications
  • Two Adjustable set point control relays
  • Natural gas and Biogas application specific sensors available
  • Field replaceable IR Source
Benefits:
  • Quick delivery on standard systems
  • Full service & training
  • Available with differing sample systems and accessories as required in various applications

1 - 1 of 1 Part Numbers
M80XP
M80XP
Model M80XP Methane Monitor
1 - 1 of 1 Part Numbers

Specifications

Operating Power

  • 24 VDC standard
  • 12 VDC, 120/240 VAC optional

Sensing Cell Proof Pressure

  • 5 to 25 psig

Measurement Range

  • 0–20% Standard
  • 0-100% Optional

Repeatability

  • ± 0.1 % of reading

Drift

  • Less than 2.5% of reading/year

Accuracy

  • ± 3% of reading or 0.1% CO2 at cal temperature
  • ± 5% of reading or 0.1% CO2 over full operating temperature range

Warmup Time

  • < 5 min

Operating Temperature

  • 10° to 50° C (standard)

Storage Temperature

  • -20° to 60° C (-4° to 140° F)

Humidity

  • Sensing Cell: 0–100% RH (Non-condensing)
  • Electronics: 0 – 90% RH (Non-condensing)

Digital Interface

  • RS-232 (all parameters)

Output

  • Analog: Isolated 4–20 mA (concentration only)
  • Alarm: 2 solid state drivers 2 Amp, 30 VDC maximum

Certifications and Approvals

  • COR
  • ISO
  • cETLus

  • CH4 Is Measured Routinely in Natural Gas for Product Quality and Process Control Purposes. Common Ranges Are from 0-5% for Sales Gas and Up to 0-30% for Inlet CH4 Concentration 
  • Biogas Plants:
    • Wastewater Facilities 
    • Agriculture/Farming 
    • Green Waste
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more