Brand: RIS - Scientific ColumbusThe Platinum 2.5K Portable Multi-Function Recorder is packaged in a rugged case with quick connect interfaces for fast and simple field connection.
Interface cables are provided with shrouded banana jacks that couple easily with a variety of measurement CT’s and voltage scaling devices offering complete flexibility for power utility and industrial use.
The Platinum 2.5K Portable Multi-Function Recorder utilizes a 40GB solid state drive that eliminates the need for a mechanical hard drive and stores over 1,000 fault and disturbance records at once.
It meets regulatory compliances including PRC-002-2.
Features- Rugged portable case with 8 analog and 16 digital inputs
- Pre-fabricated interface cables with an extensive range of measurement CT’s
- Complete solid state design with no moving parts
- Simultaneous recording of high speed fault data, disturbance recording and power quality information
- Advanced system swing detection including triggers for power and frequency oscillation
- Fault, disturbance and power quality data can be automatically exported in COMTRADE (IEEE C37.111-1999) or PQDIF (IEEE 1159.3)
- View analog, digital and computed values in real time
- Sequence of events recording provides 1msec resolution on change of state on all monitored contacts
- Phasor measurement unit-synchronized phasor measurements, in accordance
Specifications
Inputs
- Number of Channels - 8 Analog and 16 Digital
- Voltage Inputs - 63.5 or 110 V RMS Nominal, 480 or 600 V RMS Nominal (via External Box)
- Current Inputs - 1 A or 5 A RMS Nominal (thru Current Transformers, other ranges Available)
- Frequency Response - DC - 1/2 Sampling Rate (1/4 Sampling Rate for 384 Samples per Cycle only)
- Accuracy - Better than 0.1 % of Full Scale
- Digital Inputs - 24/48/125/250 Vdc Normally Open or Closed Wetted Contact
Recording (Transient)
- Recording Resolution - 16 bits, 65536 Levels (15 plus sign)
- Sample Rate - Up to 384 Samples per Cycle
- Pre-fault Time - 2 to 600 Cycles
- Post-fault Time - Fault Length will Extend as Long as a Trigger Condition Exists. Min. is 8 to 100 Cycles
- Safety Window - Recording Time after Active Trigger: 0 to 16 Cycles
- Maximum Record Length - Max. Size 1 to 60 sec. (This Prevents Memory Filling with a Continuous Trigger)
Recording (Disturbance)
- Sample Rate - 2 x Supply Frequency (100/120 Hz)
- Pre-fault - 10 sec. to 10 min.
- Post-fault Time - Fault Length will extend as long as a Trigger Point Condition Exists. Min. Value is 30 sec. to 5 min.
- Maximum Record - Absolute Max.: 30 minutes
Recording (Disturbance Logging - Optional)
- Sample Rate - 1/2 x Supply Frequency (25/30 Hz)
- Recording Time - 2 Weeks
Recording (Trend)
- Sampling Interval - 1 minute, or 10 minutes - Data can be Retrieved at up to a 60 minute Interval
- Record Length - 52 weeks (Circulating Buffer)
- Stored Parameters - Max., Min., and Average Voltage, Current, Frequency (2), Power, Flicker, Harmonics, and Imbalance. Digital Data in SER Format at User Defined Time Resolution
Triggering (Transient)
- Analog Channels - Over/Under RMS Level, Rate-of-Change and THD. Positive, Zero and Negative Sequence Triggers, Over, Under and R-o-C Frequency Triggers, Differential Frequency
- Digital Channels - Normal to Alarm State and Return to Normal State. Edge or Level Sensitive
Triggering (Disturbance)
- Analog Channels - Under/Over Level of Fundamental and R-o-C, Frequency and ROCOF, Power and Frequency Oscillation, Imbalance and Impedance, Cross Trigger from Transient Recorder
System Timing
- Time Source - Optional Internal GPS Receiver with 1 PPS Output for Phasor Measurement
- Accuracy - Normally better than ± 60 ns
Communications
- Serial Ports - 1 x RS-232 Type
- Default Setting - 57.6 kbaud, 8 bits, 1 stop, No Parity. Rates can be set up to 115 kbaud
- Network - 10baseT, Fiber, Network Protocol: TCP/IP
Data Storage
- Permanent Storage - 40 GB Flash Disk
Power Supply
- Input Voltage Options - 100 to 300 Vdc, 85 to 264 Vac, (Optional 85 to 150 Vdc, 85 to 264 Vac)
- Power Requirement - 60 VA (8 Channel)
Voltage Withstand
- Isolation, Impulse Voltage, RFI and ESD per IEEE /IEC Standards
Enclosure
- Case and Unit - 30 lbs (DIM)
Environment
- Operating Temperature - 14° F to 131° F (-10° C to 55° C)