Yodify Product Library
Instantly add the SP2000H/DIL & SP2000H320/DIL Gas Sample Probe and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
SP2000H/DIL & SP2000H320/DIL Gas Sample Probe
Brand: M&C TechGroup Germany GmbHThe non-heated or electrically heated M&C dilution unit DIL-1/H is used in analysis technique to dilute the sample gas or components in the sample for example in case of toxic gases, moisture measurement or emission measurement.
The M&C dilution unit is based on the functional dilution technique which is proved since years in the M&C gas sample probe SP2000-H/DIL.
Features- Based on probe SP2000H
- Electrically heated 0° to 180°C (32° to 356°F) or 320°C (608°F)
- External critical orifice is heated
- Including a dilution gas pre-heater
- No dew point problems
- Dilution ratios from 10:1 up to 500:1
- With check gas connection
- Independent of the process temperature
- Easy operation and maintenance
1 - 12 of 63 Part Numbers
20 S 4002
- Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
- Pressure Controller - Without Pressure Controller
- Panel - Without Control Panel
20 S 4002 20 S 4200
- Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
- Pressure Controller - 1 Pressure Controller, 2 Gauges, Mounting Set Include Connector Set for Dilution Probe
- Panel - Without Control Panel
20 S 4002 20 S 4200 20 S 4250
- Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
- Pressure Controller - 1 Pressure Controller, 2 Gauges, Mounting Set Include Connector Set for Dilution Probe
- Panel - Control Panel with 1 Pressure Controller, 2 Gauges, Flowmeter, 2 Ball Valves
20 S 4002 20 S 4200 20 S 4260
- Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
- Pressure Controller - 1 Pressure Controller, 2 Gauges, Mounting Set Include Connector Set for Dilution Probe
- Panel - Control Panel with 2 Pressure Controllers, 3 Gauges, Flowmeter, 2 Ball Valves
20 S 4002 20 S 4210
- Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
- Pressure Controller - 2 Pressure Controllers, 3 Gauges, Mounting Set Include Connector Set for Dilution Probe with Bypass
- Panel - Without Control Panel
20 S 4002 20 S 4210 20 S 4250
- Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
- Pressure Controller - 2 Pressure Controllers, 3 Gauges, Mounting Set Include Connector Set for Dilution Probe with Bypass
- Panel - Control Panel with 1 Pressure Controller, 2 Gauges, Flowmeter, 2 Ball Valves
20 S 4002 20 S 4210 20 S 4260
- Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
- Pressure Controller - 2 Pressure Controllers, 3 Gauges, Mounting Set Include Connector Set for Dilution Probe with Bypass
- Panel - Control Panel with 2 Pressure Controllers, 3 Gauges, Flowmeter, 2 Ball Valves
20 S 4002 20 S 4250
- Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
- Pressure Controller - Without Pressure Controller
- Panel - Control Panel with 1 Pressure Controller, 2 Gauges, Flowmeter, 2 Ball Valves
20 S 4002 20 S 4260
- Version - Dilution Probe 180° C (356° F) without Ball Valve Upstream of the Filter Element
- Pressure Controller - Without Pressure Controller
- Panel - Control Panel with 2 Pressure Controllers, 3 Gauges, Flowmeter, 2 Ball Valves
20 S 4005
- Version - Dilution Probe 180° C (356° F) with Heated Manual Operated Ball Valve Upstream of the Filter Element
- Pressure Controller - Without Pressure Controller
- Panel - Without Control Panel
20 S 4005 20 S 4200
- Version - Dilution Probe 180° C (356° F) with Heated Manual Operated Ball Valve Upstream of the Filter Element
- Pressure Controller - 1 Pressure Controller, 2 Gauges, Mounting Set Include Connector Set for Dilution Probe
- Panel - Without Control Panel
20 S 4005 20 S 4200 20 S 4250
- Version - Dilution Probe 180° C (356° F) with Heated Manual Operated Ball Valve Upstream of the Filter Element
- Pressure Controller - 1 Pressure Controller, 2 Gauges, Mounting Set Include Connector Set for Dilution Probe
- Panel - Control Panel with 1 Pressure Controller, 2 Gauges, Flowmeter, 2 Ball Valves
1 - 12 of 63 Part Numbers
Specifications
Flange Size - 2-1/2” (DN 65)
- 2-1/2” (DN 65) - PN 6
Flange Size - 3” (DN 80)
- 3” (DN 80) - 150# ANSI
Flow Rate
- Bypass Injector / B: Gas Pressure-Gas Flow Rate-Sample Gas Flow Rate at Approximately psig: 29.01 (kPa: 200, bar: 2) Injector Gas Approximately 300 L/hr
- Bypass Injector / B: Gas Pressure-Gas Flow Rate-Sample Gas Flow Rate at Approximately psig: 29.01 (kPa: 200, bar: 2) Sample Gas Approximately 150 L/hr
- Dilution Gas Flow Rate with Injector Version I: 480 to 600 NL/hr
- Dilution Gas Flow Rate with Injector Version II: Higher Dilution Rates 1,800 to 3,000 NL/hr
Materials of Construction
- Materials in Contact with the Sample Gas: 316 Stainless Steel
- Materials in Contact with the Sample Gas: 316Ti Stainless Steel
- Materials in Contact with the Sample Gas: FPM
- Materials in Contact with the Sample Gas: Graphite
- Materials in Contact with the Sample Gas: Quartz Glass
Mounting
- Rack-Mounted
Operating Pressure
- psia: 13.05 to 29.01 (kPa: 90 to 200, bar: 0.9 to 2)
Overpressure & Static Pressure Limits
- Fault Caused by Process Under or Overpressure: No Fault as Long as the Differential Pressure ∆P at the Dilution Unit is > psig: 7.252 (kPa: 50, bar: 0.5) & Test Gas is Given to the Probe Under Process Conditions
Power Supply
- 115 V, 60 Hz
- 230 V, 50 Hz
Pressure Range
- Dilution Gas Pressure on Inlet of Pressure Controller - psig: 65.27 to 232.1 (kPa: 450 to 1,600, bar: 4.5 to 16)
Ratio
- Dilution - 10:1 to 500:1
Temperature Range
- Electrically Heated: 0° to 320° C (32° to 608° F)
Tube Connection
- Ø 8 mm Tube, (5/16”) Use at Injector I Tube Connector 8 mm (5/16”) & at II 5/16” to 1/2” (8 to 12 mm)