ASTAT Soft Starters for 3ph Standard Induction Motors

Brand: General Electric

ASTAT S is compact, easy to operate soft starter, designed for use with standard 3-phase squirrel cage motors. 

It provides an advanced method of reducing current during motor starting and stopping. ASTAT S will start supplying a reduced voltage to the motor, increasing up to the rated voltage, so avoiding, high currents and generating soft starting and stopping.

The motor has to be able to start in a reduced voltage.
Features
  • Solid soft starter for standard 3ph AC motors up to 30kW at 400V AC
  • Voltage ratings up to 600V
  • Two phase control with integral bypass
  • Compact, small case
  • DIN rail mounting. Optional from 31A
  • Start and soft stop features

1 - 12 of 144 Part Numbers
QT10008N11DS
QT10008N11DS
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 90-230 VAC
  • Communications - DeviceNet
  • Versions - Standard
QT10008N11DSG
QT10008N11DSG
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 90-230 VAC
  • Communications - DeviceNet
  • Versions - International
QT10008N11MS
QT10008N11MS
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 90-230 VAC
  • Communications - Standard
  • Versions - Standard
QT10008N11MSG
QT10008N11MSG
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 90-230 VAC
  • Communications - Standard
  • Versions - International
QT10008N11PS
QT10008N11PS
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 90-230 VAC
  • Communications - Profibus
  • Versions - Standard
QT10008N11PSG
QT10008N11PSG
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 90-230 VAC
  • Communications - Profibus
  • Versions - International
QT10008N12DS
QT10008N12DS
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 24 Vdc
  • Communications - DeviceNet
  • Versions - Standard
QT10008N12DSG
QT10008N12DSG
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 24 Vdc
  • Communications - DeviceNet
  • Versions - International
QT10008N12MS
QT10008N12MS
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 24 Vdc
  • Communications - Standard
  • Versions - Standard
QT10008N12MSG
QT10008N12MSG
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 24 Vdc
  • Communications - Standard
  • Versions - International
QT10008N12PS
QT10008N12PS
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 24 Vdc
  • Communications - Profibus
  • Versions - Standard
QT10008N12PSG
QT10008N12PSG
  • Main Voltage - 230-500 V
  • UL Certification - Non-UL
  • Control Voltage - 110 Vac
  • Digital Inputs, Voltage - 24 Vdc
  • Communications - Profibus
  • Versions - International
1 - 12 of 144 Part Numbers

Specifications

Voltage Ratings

  • 3-Phase AC systems
  • 575/600 V (+10 %, -15 %) for units QA32P _ _ _ S
  • 480/500 V (+10 %, -15 %) for units QA22P _ _ _ S
  • 380/415 V (+10 %, -15 %) for units QA12P _ _ _ S
  • 220/230 V (+10 %, -15 %) for units QA02P_ _ _ S

Frequency Range

  • 50/60 Hz (± 5 %)

Load

  • 3-Phase, AC Standard motors

Ramp Up

  • 0.5 - 10 s (Set by Potentiometer)

Ramp Down

  • 0.5 - 10 s (Set by Potentiometer)

Initial Voltage

  • 0 to 80 % Un (Set by Potentiometer)

Starting Torque

  • 0 to 64 % Tn

I/O Controls Inputs

  • one Input for Start/Stop

I/O Controls Outputs

  • One output for «End of Ramp» signal for ratings 31, 44, 58A

Operating Temperature

  • 0° to 40° C. Up to 60° C Derating by 1.2 % Per °C

Storage Temperature

  • -20° to 70° C

Relative Humidity

  • Up to 80 %, without condensation

Maximum Altitude

  • Up to 1000 m. Above this derate by 5 % each 100 m

Protection Degree

  • IP20

  • Pumps
  • Fans
  • Compressors