ITC-7X-STX Isolated Strain Gauge Signal Conditioner Converter
Brand: Pribusin, IncThe ITC-7X-STX provides high isolation from Input to Output to Power in a small, easy to install package. The universal DIN rail mount often makes it possible to install the ITC-7X-STX right next to other instruments that it is to be wired to. The many different input and output configurations allow it to be used in a great variety of Strain Gauge applications ranging from PLC front end conditioning to stand-alone operation of weight scales.
The high output drive (1000 Ohms @ 4-20 mA) allows the ITC-7X-STX to drive several other instruments directly from its output.
Any standard Strain Gauge that has a minimum resistance of 100 ohms may be used. Standard input ranges are readily available and custom ranges are available upon request.
Features- High Input-Output-Power Isolation (1500Vac Test).
- Small Size - Fits on Terminal Block Rail.
- Adjustable Excitation Voltage (0-10 Vdc).
- Strain Gauges from 100 Ohms to 10 KOhms.
- Industry Standard Output: 4-20 mA, 1-5 Vdc, and more.
- High Output Drive on Current Outputs (1000 Ohms for 4-20 mA output).
- Power: 24 Vdc, 80 mA.
- High Noise Rejection.
- CSA and NRTL Approved (LR 51078).
Specifications
Brand
Accuracy / Linearity: ± 0.2% Maximum, ± 0.1% Typ.
- Accuracy/Linearity: ± 0.2 % Max., ± 0.1 % Typical
Common Mode Rejection
- 120 dB @ 60 Hz
Coupling Capacitance
- Input-Output-Power = 20 PF
Excitation Voltage
- 0-10 Vdc, Adjustable
Isolation
- Input to Output to Power 1500 Vac (Test)
Loop Drive
- Maximum
Loop Resistance Change Effects
- -0.03 % Per 100 ohms Change (4-20 mA Only) Calibrated at 250 ohms
Operating Temperature
- -40° to +50° C
Power
- 24 Vdc (19-29 Vdc) @ 80 mA (160 mA if Two Wire Supply Used)
Response Time
- 100 milliseconds to 63 % of Final Value, 500 milliseconds to 99 % of Final Value
Temperature Effects
- ± 0.025 % Per °C