Brand: Yokogawa Electric Corporation

The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant sensor and are suitable to measure liquid, gas, or steam pressure. 

EJA510E and EJA530E output a 4-20 mA DC signal corresponding to the measured pressure. It also features quick response, remote setup and monitoring via BRAIN or HART communications and self-diagnostics. FOUNDATION Fieldbus, PROFIBUS PA and 1-5 Vdc with HART (Low Power) protocol types are also available. 

All EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certified as complying with SIL 2 for safety requirement.
Features
  • ± 0.055% Accuracy (0.04% Accuracy optional)
  • ± 0.2% Stability per 10 years
  • 90 ms Response Time
  • Exida and TUV SIL 2/3 Certified
  • 8,700 psia Maximum Over Pressure
  • Local Parameter Setting (LPS)

Specifications

Accuracy

  • ± (0.004 URL/Span) % of Span - Includes the Effects of Terminal-based Linearity, Hysteresis, & Repeatability: High Accuracy
  • ± (0.005 + 0.0035 URL/Span) % of Span - Includes the Effects of Terminal-based Linearity, Hysteresis, & Repeatability: High Accuracy
  • ± (0.0055 URL/Span) % of Span - Includes the Effects of Terminal-based Linearity, Hysteresis, & Repeatability
  • ± (0.0064 x 50 MPa/Span) % of Span - Includes the Effects of Terminal-based Linearity, Hysteresis, & Repeatability: High Accuracy
  • ± (0.0088 x 50 MPa/Span) % of Span - Includes the Effects of Terminal-based Linearity, Hysteresis, & Repeatability
  • ± 0.04 % of Span - Including the Effects of Zero-based Linearity, Hysteresis, & Repeatability
  • ± 0.055 % of Span - Including the Effects of Zero-based Linearity, Hysteresis, & Repeatability

Adjustment Type

  • External Zero Adjustment Screw
  • Push Button

Alarm

  • Down-Scale: -5 %, 0.8 Vdc or Less for 1-5 V HART
  • Down-Scale: -5 %, 3.2 mA DC or Less for 4-20 mA HART/BRAIN
  • Up-Scale: 110 %, 21.6 mA DC or more for 4-20 mA HART/BRAIN
  • Up-Scale: 110 %, 5.4 Vdc or more for 1-5 V HART

Ambient Temperature Range

  • -30° to 80° C (-22° to 176° F) - with LCD Display
  • -40° to 85° C (-40° to 185° F)

Approvals & Certifications

  • Leak Test
  • Material Certificate
  • Pressure Test
  • SIL Certification - SIL 2 Capability for Single Transmitter Use, SIL 3 Capability for Dual Transmitter Use, IEC 61508: 2000

Approvals & Certifications

  • ATEX Flameproof & Intrinsically Safe
  • CE
  • CSA Explosion-proof & Intrinsically Safe
  • EMC EN 61326-1 Class A (For Industrial Locations), EN 61326-2-3, EN 61326-2-5 (For Fieldbus)
  • FM Explosion-proof & Intrinsically Safe
  • IEC Ex Flameproof & Intrinsically Safe
  • NAMUR NE43
  • PED 2014/68/EU Sound Engineering Practice (For All Capsules)

BSP Connection

  • G 1/2” DIN 16 288 Male

Burst Pressure

  • psi: 19,140 (kPa: 132,000, bar: 1,320) for Capsule D
  • psi: 4,351 (kPa: 30,000, bar: 300) for Capsule A, B & C

Cable Material

  • Polyethylene Insulated PVC Sheathed

Communication

  • BRAIN
  • FOUNDATION Fieldbus
  • HART FSK Protocol
  • PROFIBUS PA

Connection Material

  • 316L Stainless Steel
  • Hastelloy C-276

Consumption

  • 0.96-3 mA - Power Consumption
  • 27 mW - Power Consumption

Damping Adjustment

  • 0 to 100 seconds

Dead Time

  • 45 milliseconds (Nominal)

Diagnostics

  • Alarm - User-Configurable Process High/Low Alarm for Pressure
  • Configuration Error
  • CPU Failure
  • Hardware Failure
  • Process Alarm for Pressure or Capsule Temperature

Diaphragm Material

  • Hastelloy C-276

Display

  • 5-Digit Numerical Display
  • 6-Digit Unit Display
  • Bar Graph
  • LCD Display
  • User-Configurable 10-Segment Signal Characterizer for 4-20 mA Output

Distance

  • 2 Kilometers (1.25 Miles) - Communication Distance

Electrical Connectors

  • 1/2” NPT Female
  • Blind Plug
  • G 1/2” Female
  • M20 Female

Enclosure Finish

  • Anti-Corrosion Coating
  • Polyurethane Paint, Deep Sea Moss Green Paint (Munsell 0.6 GY3.1/2.0 or its Equivalent)

Enclosure, Body Material

  • ASTM CF-8M Stainless Steel
  • Low Copper Cast Aluminum Alloy

Environmental Protection

  • IP66
  • IP67
  • NEMA 4X

Fill Material

  • Fluorinated Oil
  • Silicone

Humidity

  • 0 to 100 % Relative Humidity - Ambient Humidity

Indication

  • Digital

Input Impedance

  • 10 kiloohms or more at 2.4 kHz - Communicating Device

Load

  • 0 to 1,290 ohms - for Operation
  • 0.22 µF or Less - Load Capacitance
  • 250 to 600 ohms for Digital Communication
  • 3.3 MH or Less - Load Inductance

Materials of Construction

  • 316 Stainless Steel - Name Plate & Tag, Mounting Bracket
  • Polypropylene - Pipe

Media

  • Liquids & Gases
  • Water

Metric Connection

  • M20 x 1.5 Male DIN 16288

Mounting

  • 2” (50.8 mm) Pipe Mounting Bracket

Mounting Position Effect

  • Tilting up to 90° will cause Zero Shift up to 0.21 kPa

NACE & NIST

  • NACE

NPT Connection

  • 1/2” NPT Female
  • 1/2” NPT Male

O-Ring Material

  • Buna-N: Cover O-Rings
  • Fluororubber: Cover O-Ring

Operating Temperature

  • -20° to 80° C (-4° to 176° F)

Output

  • 0.9-5.4 Vdc - Output Range for 1-5 V HART
  • 1-5 Vdc (3 or 4-Wire)
  • 3.6-21.6 mA - Output Range for 4-20 mA HART/BRAIN
  • 4-20 mA DC (2-Wire)

Output Load

  • 1 Megaohm or Greater for 1-5 V HART

Overpressure & Static Pressure Limits

  • psi: 2,900 (kPa: 20,000, bar: 200) - Max.
  • psi: 580 (kPa: 4,000, bar: 40) - Max.
  • psi: 8,700 (kPa: 59,980, bar: 599.8) - Max.

Power Requirement

  • 9-28 Vdc - for General Use & Flameproof Typical

Power Supply Effect

  • ± 0.005 % Per Volt (21.6-32 Vdc, 350 ohms)

Pressure Range

  • bar: -1 to 500
  • MPa: -0.1 to 50
  • psi: -14.5 to 7,200

Pressure Type

  • Absolute

Process Temperature

  • -40° to 120° C (-40° to 248° F)

Response Time

  • 90 milliseconds

Stability

  • ± 0.2 % of URL for 10-Years

Supply Pressure - Maximum

  • psi: 1,450 (kPa: 10,000, bar: 100) for Capsule C
  • psi: 29.01 (kPa: 200, bar: 2) for Capsule A
  • psi: 290.1 (kPa: 2,000, bar: 20) for Capsule B
  • psi: 7,200 (kPa: 49,640, bar: 496.4) for Capsule D

Supply Voltage

  • 10.5-30 Vdc - for Intrinsically Safe, Typical N, Non-Incendive
  • 10.5-32 Vdc - for Lightning Protector
  • 10.5-42 Vdc - for General Use & Flameproof Typical
  • 16.6 Vdc - for Digital Communications, BRAIN & HART
  • 24 Vdc - up to 550 ohms Load

Temperature Effect

  • ± (0.15 % of Span + 0.15 % of 50 MPa) Per 28° C (50° F) - Capsule D Ambient Temperature Effect
  • ± (0.15 % of Span + 0.15 % of URL) Per 28° C (50° F) - Capsule A, B & C Ambient Temperature Effect

Update Time

  • 45 milliseconds - Pressure

Vibration Effect

  • < ± 0.1 % of URL Per IEC 60770-1 with Low Vibration Level (10-60 Hz, 0.15 mm Displacement / 60-500 Hz 2 G)
  • < 0.1 % of URL Per IEC 60770-1 with High Vibration Level (10-60 Hz, 0.21 mm Displacement / 60-2,000 Hz 3 G)

Wetted Materials

  • 316L Stainless Steel
  • Hastelloy C-276

Zero Offset

  • External Zero is Continuously Aadjustable with 0.01 % Incremental Resolution of Span
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team