Yodify Product Library
Instantly add the GM90MB Module Base and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
GM90MB Module Base
Brand: Yokogawa Electric CorporationThe Data Acquisition System GM is a data logger that excels in versatility and expandability. The main unit includes on-board memory for data acquisition and also supports SD cards for external storage.
The system consists of a Data Acquisition Module (GM10), Power Supply Module (GM90PS), and Module Base (GM90MB), which is used to mount a variety of modules.
FeaturesScalability:
- Up to 420 channels per system
- Plug and lock modules
Ease of Use:
- Web-based configuration
- Live web-based data viewing
Mobile Connectivity:
- Bluetooth
- Mobile application
Reliability:
- Secure data storage
- High accuracy measurement
- Automatic backfill function (GA10 data logging software)
Noise Tolerance:
- Electromagnetic relay module
Specifications
Ambient Temperature Range
- -20° to 60° C (-4° to 140° F)
Approvals & Certifications
- CE
- CSA 22.2 No61010-1, CSA 22.2 No.61010-2-030-12
- EMC: EN 301 489-1, EN 301 489-17, EN 61326-1, EN 61326-1 Class A Table 2, EN 61000-3-2, EN 61000-3-3, EN 55011 Class A Group 1
- KC
- LVD: EN 61010-1, EN 61010-2-030
- NRTL
- RCM: AS/NZS4268, AS/NZS2772.2
- UL 61010-1, UL 61010-2-030 (CSA NRTL/C)
- WEEE Directive Support
Approvals & Certifications
- R & TTE Directive - EN 61010-1, EN 61010-2-030, EN 62311
Communication
- Bluetooth
- DARWIN
- Ethernet - 10Base-T/100Base-TX Port
- EtherNet/IP
- Modbus RTU
- Modbus TCP/IP
- RS-422, RS-485
- Serial Communication Port
- SSL
- USB 2.0
- Wireless
Display
- 7-Segment LED
Electrical Connectors
- M3 Screw Terminal
Frequency
- 50/60 Hz ± 1 %
Humidity
- 20 to 85 % Relative Humidity, Non-Condensing - Ambient Humidity
- 55 ± 10 % Relative Humidity, 23 ± 2° C (73.4 ± 3.6° F) - General Operating Condition
Input
- 20 mV - DCV
- -200 mV to 50 V - DCV
- 6 V (1-5 V) - DCV
Measurement Accuracy
- DCV: ± (0.01 % of Reading + 2 mV) - 6 V (1-5 V)
- DCV: ± (0.01 % of Reading + 5 μV) - 20 mV
- ± [0.02 % of Reading + 0.16° C (0.288° F)] - Pt100 (High Resolution)
- ± [0.02 % of Reading + 0.2° C (0.36° F)] - Pt100
- ± 0.2° C (± 0.36° F), However, -200° to 0° C (-328° to 0° F): ± [0.15 % of Reading + 0.2° C (0.36° F)] - K Thermocouple [-200° to 500° C (-328° to 932° F)]
- ± 0.2° C (± 0.36° F), However, -200° to 0° C (-328° to 32° F): ± [0.10 % of Reading + 0.2° C (0.36° F)] - T Thermocouple
- ± 1.1° C (± 1.98° F) - R Thermocouple
Mounting
- Clamp Terminal
- Desktop
- DIN Rail
- Wall Mounted
Operating Temperature
- -20° to 60° C (-4° to 140° F)
Resistance
- 1 Kiloohm or Less (ON) - Contact DI
- 100 kiloohms or more (OFF) - Contact DI
RFI/EMI Effect
- 400 A/m or Less (DC & 50/60 Hz) - Magnetic Field
RTD Type
- Cu10
- Cu100
- Cu25
- Cu50
- Cu53
- JPt100
- Ni100
- Ni120
- Pt100
- Pt200
- Pt25
- Pt46
- Pt50
Sensor, Probe Type
- B Thermocouple
- E Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- N Thermocouple
- RTD
- R Thermocouple
- S Thermocouple
- T Thermocouple
- U Thermocouple
- W Thermocouple
Shock
- When Off, 500 m/sec² or Less, Approximately 10 milliseconds, 3 times in 6 Directions (± X, ± Y, ± Z)
- When On, 98 m/sec² or Less, 11 milliseconds, 3 times in 6 Directions (± X, ± Y, ± Z)
Temperature Range
- -200° to 850° C (-328° to 1,562° F) - RTD
- -270° to 2,320° C (-454° to 4,208° F) - Thermocouples
Update Time
- 30 minutes - Warmup Time
Vibration
- 5 ≤ F < 8.4 Hz Amplitude 3.5 mm Peak
- 8.4 ≤ F ≤ 160 Hz Acceleration 9.8 m/sec²