Yodify Product Library
Instantly add the Emergency Luminaire with LED EXLUX Series 6009/1 Version IIC and 50,000+ more product series to yourĀ store or catalogĀ Ā
Book Your Demo and See How
or create your store
Emergency Luminaire with LED EXLUX Series 6009/1 Version IIC
Brand: R. STAHL AGThe luminaires of the series EXLUX 6009 LED can be used for safety lighting.
Features- For use in hazardous areas with gas group IIC
- Emergency luminaire for wall, ceiling, pendant or pole installation
- Latest LED technology with a high luminous efficacy and a long service life
- Central locking system
- Weekly functional test
- Annually rated operating time test
1 - 8 of 8 Part Numbers
254253
For use in hazardous areas with gas group IIC
Emergency luminaire for wall, ceiling, pendant or pole installation
Latest LED technology with a high luminous efficacy and a long service life
Central locking system
Weekly functional test
Annually rated operating time test
254254
For use in hazardous areas with gas group IIC
Emergency luminaire for wall, ceiling, pendant or pole installation
Latest LED technology with a high luminous efficacy and a long service life
Central locking system
Weekly functional test
Annually rated operating time test
Ambient Conditions
- Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
- Ambient temperature °F - -999 - -999 °F
- Ambient temperature max. - +50 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Components
- Ballast - 6046/111-111-020 LED NLE 60 W
- Battery-Version - NiCd battery, gas-tight
- Drilled holes - 3 x M25
- Material of screw connections - Polyamide, black
- Screw connections - 2 x M25 Ø 7 – 17 mm
- Stopping plug - 2 x M25 x 1.5
- Stopping plug material - Polyamide, black
- Threaded plate - 2x Plastic
- Through wiring - with 6 conductors 2.5 mm2
Electrical Data
- Battery capacity - 7 Ah
- Battery operating voltage - 6 V
- Ex version - Yes
- Frequency range - 50 - 60 Hz
- Rated operational voltage AC - 110.00 - 240.00 V
- Rated operational voltage max. AC - 240.00 V
- Rated operational voltage min. AC - 110.00 V
- Self-test function - with (Standard)
Explosion Protection
- Ambient temperature °C - -20 - 50 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - IBExU 16 ATEX 1199
- ATEX gas certificate - IBExU 16 ATEX 1199
- Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
- Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
- Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIC T4 Gb
- Gas explosion protection IECEx - Ex db eb mb op is IIC T4 Gb
- IECEX dust certificate - IECEx IBE 16.0038
- IECEX gas certificate - IECEx IBE 16.0038
- Languages of the documentation - English, German
- Note: Through wiring - max. 3x16 A
- Note: Through wiring 2 - max. 3x10 A
General
- Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
- Highlights - For use in hazardous areas with gas group IIC Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
- Product Description - Emergency luminaire with LED GRP
- Product Type - 6009/1482-171-7601-131-00
- Title Product Variant Technical Data - 6009/1482-171-7601-131-00 LED em.light
- WebCode - 6009C
Lighting Data
- Colour rendering - ≥ 80
- Colour temperature - 5000 K
- Emergency light mode - Continuous light or stand-by light
- Lamp - LED
- Lamp wattage - 52 W
- Light colour - neutral white
- Light distribution - 120°x120° with diffusing glass
- Luminaire efficacy - 90 Im/W
- Luminous flux - 4700 lm
- Number of Lamps - 1
- Operating time - 1.5 / 3h emergency lighting operation
Mechanical Data
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals solid max. - 4.00 mm²
- Degree of protection IP (IEC 60598) - IP66 / IP67
- Design size - 4
- Diffuser - With diffuser
- Dimension L3 - 670.000 - 930.000 mm
- Enclosure colour - light grey (RAL 7035)
- Enclosure material - Polyester resin, Glass fibre reinforced
- Height - 125.000 mm
- Impact strength (IK code) - IK10 (IEC 62262)
- Installed terminal strip - PE + N + L1 + L2 + L3 + L´
- Length - 1467.000 mm
- Material translucent cover - Polycarbonate
- Protection class - I (with inner PE connection)
- Sealing material - Silicone
- Type of connection cable - Finely stranded, solid
- Version - Standard
- Weight - 9.350 kg
- Width - 183.500 mm
254262
For use in hazardous areas with gas group IIC
Emergency luminaire for wall, ceiling, pendant or pole installation
Latest LED technology with a high luminous efficacy and a long service life
Central locking system
Weekly functional test
Annually rated operating time test
Ambient Conditions
- Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
- Ambient temperature °F - -999 - -999 °F
- Ambient temperature max. - +50 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Components
- Ballast - 6046/111-111-020 LED NLE 60 W
- Battery-Version - NiCd battery, gas-tight
- Drilled holes - 3 x M25
- Material of screw connections - Polyamide, black
- Screw connections - 2 x M25 Ø 7 – 17 mm
- Stopping plug - 2 x M25 x 1.5
- Stopping plug material - Polyamide, black
- Threaded plate - 2x Plastic
- Through wiring - with 6 conductors 2.5 mm2
Electrical Data
- Battery capacity - 7 Ah
- Battery operating voltage - 6 V
- Ex version - Yes
- Frequency range - 50 - 60 Hz
- Rated operational voltage AC - 110.00 - 240.00 V
- Rated operational voltage max. AC - 240.00 V
- Rated operational voltage min. AC - 110.00 V
- Self-test function - with (Standard)
Explosion Protection
- Ambient temperature °C - -20 - 50 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - IBExU 16 ATEX 1199
- ATEX gas certificate - IBExU 16 ATEX 1199
- Certificate EAC - IBExU16ATEX1199
- Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
- Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
- Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
- Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIC T4 Gb
- Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
- Gas explosion protection IECEx - Ex db eb mb op is IIC T4 Gb
- IECEX dust certificate - IECEx IBE 16.0038
- IECEX gas certificate - IECEx IBE 16.0038
- Languages of the documentation - English, German
- Note: Through wiring - max. 3x16 A
- Note: Through wiring 2 - max. 3x10 A
General
- Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
- Highlights - For use in hazardous areas with gas group IIC Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
- Product Description - Emergency luminaire with LED GRP
- Product Type - 6009/1282-171-7601-131-00
- Title Product Variant Technical Data - 6009/1282-171-7601-131-00 LED em.light
- WebCode - 6009C
Lighting Data
- Colour rendering - ≥ 80
- Colour temperature - 5000 K
- Emergency light mode - Continuous light or stand-by light
- Lamp - LED
- Lamp wattage - 28 W
- Light colour - neutral white
- Light distribution - 120°x120° with diffusing glass
- Luminaire efficacy - 84 Im/W
- Luminous flux - 2350 lm
- Number of Lamps - 1
- Operating time - 1.5 / 3h emergency lighting operation
Mechanical Data
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals solid max. - 4.00 mm²
- Degree of protection IP (IEC 60598) - IP66 / IP67
- Design size - 2
- Diffuser - With diffuser
- Dimension L3 - 320.000 - 480.000 mm
- Enclosure colour - light grey (RAL 7035)
- Enclosure material - Polyester resin, Glass fibre reinforced
- Height - 125.000 mm
- Impact strength (IK code) - IK10 (IEC 62262)
- Installed terminal strip - PE + N + L1 + L2 + L3 + L´
- Length - 857.000 mm
- Material translucent cover - Polycarbonate
- Protection class - I (with inner PE connection)
- Sealing material - Silicone
- Type of connection cable - Finely stranded, solid
- Version - Standard
- Weight - 6.700 kg
- Width - 183.500 mm
254266
For use in hazardous areas with gas group IIC
Emergency luminaire for wall, ceiling, pendant or pole installation
Latest LED technology with a high luminous efficacy and a long service life
Central locking system
Weekly functional test
Annually rated operating time test
Ambient Conditions
- Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
- Ambient temperature °F - -999 - -999 °F
- Ambient temperature max. - +50 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Components
- Ballast - 6046/111-111-020 LED NLE 60 W
- Battery-Version - NiCd battery, gas-tight
- Drilled holes - 3 x M20
- Screw connections - Can be ordered as accessories
- Stopping plug - Can be ordered as accessories
- Threaded plate - 2x SS430 stainless steel
- Through wiring - with 6 conductors 2.5 mm2
Electrical Data
- Battery capacity - 7 Ah
- Battery operating voltage - 6 V
- Ex version - Yes
- Frequency range - 50 - 60 Hz
- Lamp wattage - 28 W
- Rated operational voltage AC - 110.00 - 240.00 V
- Rated operational voltage max. AC - 240.00 V
- Rated operational voltage min. AC - 110.00 V
- Self-test function - with (Standard)
Explosion Protection
- Ambient temperature °C - -20 - 50 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - IBExU 16 ATEX 1199
- ATEX gas certificate - IBExU 16 ATEX 1199
- Certificate EAC - IBExU16ATEX1199
- Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
- Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
- Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
- Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIC T4 Gb
- Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
- Gas explosion protection IECEx - Ex db eb mb op is IIC T4 Gb
- IECEX dust certificate - IECEx IBE 16.0038
- IECEX gas certificate - IECEx IBE 16.0038
- Languages of the documentation - English, German
- Note: Through wiring - max. 3x16 A
- Note: Through wiring 2 - max. 3x10 A
General
- Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
- Highlights - For use in hazardous areas with gas group IIC Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
- Product Description - Emergency luminaire with LED GRP
- Product Type - 6009/1282-171-7601-232-00
- Title Product Variant Technical Data - 6009/1282-171-7601-232-00 LED em.light
- WebCode - 6009C
Lighting Data
- Colour rendering - ≥ 80
- Colour temperature - 5000 K
- Emergency light mode - Continuous light or stand-by light
- Lamp - LED
- Light colour - neutral white
- Light distribution - 120°x120° with diffusing glass
- Luminaire efficacy - 84 Im/W
- Luminous flux - 2350 lm
- Number of Lamps - 1
- Operating time - 1.5 / 3h emergency lighting operation
Mechanical Data
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals solid max. - 4.00 mm²
- Degree of protection IP (IEC 60598) - IP66 / IP67
- Design size - 2
- Diffuser - With diffuser
- Dimension L3 - 320.000 - 480.000 mm
- Enclosure colour - light grey (RAL 7035)
- Enclosure material - Polyester resin, Glass fibre reinforced
- Height - 125.000 mm
- Impact strength (IK code) - IK10 (IEC 62262)
- Installed terminal strip - PE + N + L1 + L2 + L3 + L´
- Length - 857.000 mm
- Material translucent cover - Polycarbonate
- Protection class - I (with inner PE connection)
- Sealing material - Silicone
- Type of connection cable - Finely stranded, solid
- Version - Standard
- Weight - 6.750 kg
- Width - 183.500 mm
256278
For use in hazardous areas with gas group IIC
Emergency luminaire for wall, ceiling, pendant or pole installation
Latest LED technology with a high luminous efficacy and a long service life
Central locking system
Weekly functional test
Annually rated operating time test
Ambient Conditions
- Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
- Ambient temperature °F - -999 - -999 °F
- Ambient temperature max. - +50 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Components
- Ballast - 6046/111-111-020 LED NLE 60 W
- Battery-Version - NiCd battery, gas-tight
- Drilled holes - 3 x M20
- Screw connections - Can be ordered as accessories
- Stopping plug - Can be ordered as accessories
- Threaded plate - 2x SS430 stainless steel
- Through wiring - with 6 conductors 2.5 mm2
Electrical Data
- Battery capacity - 7 Ah
- Battery operating voltage - 6 V
- Ex version - Yes
- Frequency range - 50 - 60 Hz
- Lamp wattage - 52 W
- Rated operational voltage AC - 110.00 - 240.00 V
- Rated operational voltage max. AC - 240.00 V
- Rated operational voltage min. AC - 110.00 V
- Self-test function - with (Standard)
Explosion Protection
- Ambient temperature °C - -20 - 50 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - IBExU 16 ATEX 1199
- ATEX gas certificate - IBExU 16 ATEX 1199
- Certificate EAC - IBExU16ATEX1199
- Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
- Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
- Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
- Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIC T4 Gb
- Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
- Gas explosion protection IECEx - Ex db eb mb op is IIC T4 Gb
- IECEX dust certificate - IECEx IBE 16.0038
- IECEX gas certificate - IECEx IBE 16.0038
- Languages of the documentation - English, German
- Note: Through wiring - max. 3x16 A
- Note: Through wiring 2 - max. 3x10 A
General
- Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
- Highlights - For use in hazardous areas with gas group IIC Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
- Product Description - Emergency luminaire with LED GRP
- Product Type - 6009/1482-171-7611-232-00
- Title Product Variant Technical Data - 6009/1482-171-7611-232-00 LED em.light
- WebCode - 6009C
Lighting Data
- Colour rendering - ≥ 80
- Colour temperature - 5000 K
- Emergency light mode - Continuous light or stand-by light
- Lamp - LED
- Light colour - neutral white
- Light distribution - 120°x120° with diffusing glass
- Luminaire efficacy - 90 Im/W
- Luminous flux - 4700 lm
- Number of Lamps - 1
- Operating time - 1.5 / 3h emergency lighting operation
Mechanical Data
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals solid max. - 4.00 mm²
- Degree of protection IP (IEC 60598) - IP66 / IP67
- Design size - 4
- Diffuser - With diffuser
- Dimension L3 - 670.000 - 930.000 mm
- Enclosure colour - light grey (RAL 7035)
- Enclosure material - Polyester resin, Glass fibre reinforced
- Height - 125.000 mm
- Impact strength (IK code) - IK10 (IEC 62262)
- Installed terminal strip - PE + N + L1 + L2 + L3 + L´
- Length - 1467.000 mm
- Material translucent cover - Polycarbonate
- Protection class - I (with inner PE connection)
- Sealing material - Silicone
- Type of connection cable - Finely stranded, solid
- Version - Standard
- Weight - 9.350 kg
- Width - 183.500 mm
256280
For use in hazardous areas with gas group IIC
Emergency luminaire for wall, ceiling, pendant or pole installation
Latest LED technology with a high luminous efficacy and a long service life
Central locking system
Weekly functional test
Annually rated operating time test
Ambient Conditions
- Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
- Ambient temperature °F - -999 - -999 °F
- Ambient temperature max. - +50 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Components
- Ballast - 6046/111-111-020 LED NLE 60 W
- Battery-Version - NiCd battery, gas-tight
- Drilled holes - 3 x M20
- Screw connections - Can be ordered as accessories
- Stopping plug - Can be ordered as accessories
- Threaded plate - 2x SS430 stainless steel
- Through wiring - with 6 conductors 2.5 mm2
Electrical Data
- Battery capacity - 7 Ah
- Battery operating voltage - 6 V
- Ex version - Yes
- Frequency range - 50 - 60 Hz
- Lamp wattage - 28 W
- Rated operational voltage AC - 110.00 - 240.00 V
- Rated operational voltage max. AC - 240.00 V
- Rated operational voltage min. AC - 110.00 V
- Self-test function - with (Standard)
Explosion Protection
- Ambient temperature °C - -20 - 50 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - IBExU 16 ATEX 1199
- ATEX gas certificate - IBExU 16 ATEX 1199
- Certificate EAC - IBExU16ATEX1199
- Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
- Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
- Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
- Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIC T4 Gb
- Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
- Gas explosion protection IECEx - Ex db eb mb op is IIC T4 Gb
- IECEX dust certificate - IECEx IBE 16.0038
- IECEX gas certificate - IECEx IBE 16.0038
- Languages of the documentation - English, German
- Note: Through wiring - max. 3x16 A
- Note: Through wiring 2 - max. 3x10 A
General
- Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
- Highlights - For use in hazardous areas with gas group IIC Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
- Product Description - Emergency luminaire with LED GRP
- Product Type - 6009/1282-171-7611-232-00
- Title Product Variant Technical Data - 6009/1282-171-7611-232-00 LED em.light
- WebCode - 6009C
Lighting Data
- Colour rendering - ≥ 80
- Colour temperature - 5000 K
- Emergency light mode - Continuous light or stand-by light
- Lamp - LED
- Light colour - neutral white
- Light distribution - 120°x120° with diffusing glass
- Luminaire efficacy - 84 Im/W
- Luminous flux - 2350 lm
- Number of Lamps - 1
- Operating time - 1.5 / 3h emergency lighting operation
Mechanical Data
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals solid max. - 4.00 mm²
- Degree of protection IP (IEC 60598) - IP66 / IP67
- Design size - 2
- Diffuser - With diffuser
- Dimension L3 - 320.000 - 480.000 mm
- Enclosure colour - light grey (RAL 7035)
- Enclosure material - Polyester resin, Glass fibre reinforced
- Height - 125.000 mm
- Impact strength (IK code) - IK10 (IEC 62262)
- Installed terminal strip - PE + N + L1 + L2 + L3 + L´
- Length - 857.000 mm
- Material translucent cover - Polycarbonate
- Protection class - I (with inner PE connection)
- Sealing material - Silicone
- Type of connection cable - Finely stranded, solid
- Version - Standard
- Weight - 6.830 kg
- Width - 183.500 mm
256332
For use in hazardous areas with gas group IIC
Emergency luminaire for wall, ceiling, pendant or pole installation
Latest LED technology with a high luminous efficacy and a long service life
Central locking system
Weekly functional test
Annually rated operating time test
Ambient Conditions
- Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
- Ambient temperature °F - -999 - -999 °F
- Ambient temperature max. - +50 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Components
- Ballast - 6046/111-111-020 LED NLE 60 W
- Battery-Version - NiCd battery, gas-tight
- Drilled holes - 3 x M25
- Material of screw connections - Polyamide, black
- Screw connections - 2 x M25 Ø 7 – 17 mm
- Stopping plug - 2 x M25 x 1.5
- Stopping plug material - Polyamide, black
- Threaded plate - 2x Plastic
- Through wiring - with 6 conductors 2.5 mm2
Electrical Data
- Battery capacity - 7 Ah
- Battery operating voltage - 6 V
- Ex version - Yes
- Frequency range - 50 - 60 Hz
- Lamp wattage - 52 W
- Rated operational voltage AC - 110.00 - 240.00 V
- Rated operational voltage max. AC - 240.00 V
- Rated operational voltage min. AC - 110.00 V
- Self-test function - with (Standard)
Explosion Protection
- Ambient temperature °C - -20 - 50 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - IBExU 16 ATEX 1199
- ATEX gas certificate - IBExU 16 ATEX 1199
- Certificate EAC - IBExU16ATEX1199
- Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
- Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
- Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
- Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIC T4 Gb
- Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
- Gas explosion protection IECEx - Ex db eb mb op is IIC T4 Gb
- IECEX dust certificate - IECEx IBE 16.0038
- IECEX gas certificate - IECEx IBE 16.0038
- Languages of the documentation - English, German
- Note: Through wiring - max. 3x16 A
- Note: Through wiring 2 - max. 3x10 A
General
- Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
- Highlights - For use in hazardous areas with gas group IIC Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
- Product Description - Emergency luminaire with LED GRP
- Product Type - 6009/1482-171-7611-131-00
- Title Product Variant Technical Data - 6009/1482-171-7611-131-00 LED em.light
- WebCode - 6009C
Lighting Data
- Colour rendering - ≥ 80
- Colour temperature - 5000 K
- Emergency light mode - Continuous light or stand-by light
- Lamp - LED
- Light colour - neutral white
- Light distribution - 120°x120° with diffusing glass
- Luminaire efficacy - 90 Im/W
- Luminous flux - 4700 lm
- Number of Lamps - 1
- Operating time - 1.5 / 3h emergency lighting operation
Mechanical Data
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals solid max. - 4.00 mm²
- Degree of protection IP (IEC 60598) - IP66 / IP67
- Design size - 4
- Diffuser - With diffuser
- Dimension L3 - 670.000 - 930.000 mm
- Enclosure colour - light grey (RAL 7035)
- Enclosure material - Polyester resin, Glass fibre reinforced
- Height - 125.000 mm
- Impact strength (IK code) - IK10 (IEC 62262)
- Installed terminal strip - PE + N + L1 + L2 + L3 + L´
- Length - 1467.000 mm
- Material translucent cover - Polycarbonate
- Protection class - I (with inner PE connection)
- Sealing material - Silicone
- Type of connection cable - Finely stranded, solid
- Version - Standard
- Weight - 9.350 kg
- Width - 183.500 mm
256334
For use in hazardous areas with gas group IIC
Emergency luminaire for wall, ceiling, pendant or pole installation
Latest LED technology with a high luminous efficacy and a long service life
Central locking system
Weekly functional test
Annually rated operating time test
Ambient Conditions
- Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
- Ambient temperature °F - -999 - -999 °F
- Ambient temperature max. - +50 °C
- Ambient temperature max.2 - +55 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
Components
- Ballast - 6046/111-111-020 LED NLE 60 W
- Battery-Version - NiCd battery, gas-tight
- Drilled holes - 3 x M25
- Material of screw connections - Polyamide, black
- Screw connections - 2 x M25 Ø 7 – 17 mm
- Stopping plug - 2 x M25 x 1.5
- Stopping plug material - Polyamide, black
- Threaded plate - 2x Plastic
- Through wiring - with 6 conductors 2.5 mm2
Electrical Data
- Battery capacity - 7 Ah
- Battery operating voltage - 6 V
- Ex version - Yes
- Frequency range - 50 - 60 Hz
- Lamp wattage - 28 W
- Rated operational voltage AC - 110.00 - 240.00 V
- Rated operational voltage max. AC - 240.00 V
- Rated operational voltage min. AC - 110.00 V
- Self-test function - with (Standard)
Explosion Protection
- Ambient temperature °C - -20 - 50 °C
- Ambient temperature °C 2 - -20 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - IBExU 16 ATEX 1199
- ATEX gas certificate - IBExU 16 ATEX 1199
- Certificate EAC - IBExU16ATEX1199
- Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
- Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
- Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
- Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIC T4 Gb
- Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
- Gas explosion protection IECEx - Ex db eb mb op is IIC T4 Gb
- IECEX dust certificate - IECEx IBE 16.0038
- IECEX gas certificate - IECEx IBE 16.0038
- Languages of the documentation - English, German
- Note: Through wiring - max. 3x16 A
- Note: Through wiring 2 - max. 3x10 A
General
- Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
- Highlights - For use in hazardous areas with gas group IIC Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
- Product Description - Emergency luminaire with LED GRP
- Product Type - 6009/1282-171-7611-131-00
- Title Product Variant Technical Data - 6009/1282-171-7611-131-00 LED em.light
- WebCode - 6009C
Lighting Data
- Colour rendering - ≥ 80
- Colour temperature - 5000 K
- Emergency light mode - Continuous light or stand-by light
- Lamp - LED
- Light colour - neutral white
- Light distribution - 120°x120° with diffusing glass
- Luminaire efficacy - 84 Im/W
- Luminous flux - 2350 lm
- Number of Lamps - 1
- Operating time - 1.5 / 3h emergency lighting operation
Mechanical Data
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals solid max. - 4.00 mm²
- Degree of protection IP (IEC 60598) - IP66 / IP67
- Design size - 2
- Diffuser - With diffuser
- Dimension L3 - 320.000 - 480.000 mm
- Enclosure colour - light grey (RAL 7035)
- Enclosure material - Polyester resin, Glass fibre reinforced
- Height - 125.000 mm
- Impact strength (IK code) - IK10 (IEC 62262)
- Installed terminal strip - PE + N + L1 + L2 + L3 + L´
- Length - 857.000 mm
- Material translucent cover - Polycarbonate
- Protection class - I (with inner PE connection)
- Sealing material - Silicone
- Type of connection cable - Finely stranded, solid
- Version - Standard
- Weight - 6.780 kg
- Width - 183.500 mm
1 - 8 of 8 Part Numbers