Operator Station OS ET-667
Brand: R. STAHL AGThe OS ET-667-DVI3 HMI series includes KVM Operator Stations for zones 1, 2, 21, 22 and Division 2.
Their brilliant 22" widescreen displays with a resolution of 1680 x 1050 pixels (format 16:10), and are available with or without touch screen.
The stainless steel enclosures (SS304 or SS316L) are available with a front opening or in cleanroom-compliant design and with different mounting options.
Country-specific keyboards, pointer instruments and RFID and barcode scanners are useful accessories making work easier and extending functionality.
Depending on the distance to be crossed, you may choose from the following types of data transmission technology: via copper cable up to 150 m, via multimode fibre optic up to 550 m or via single mode fibre optic up to 10 km.
Features- KVM Operator Station, 22" display, 1680 x 1050
- Zone 1, 2, 21, 22 and Division 2
- Display of the 19" (1280 x 1024) resolution true to 5:4 format
- Optional resistive glass or foil touch screen
1 - 1 of 1 Part Numbers
ET667A
KVM Operator Station, 22" display, 1680 x 1050
Zone 1, 2, 21, 22 and Division 2
Display of the 19" (1280 x 1024) resolution true to 5:4 format
Optional resistive glass or foil touch screen
Ambient Conditions
- Ambient temperature operation - -20 °C … +55 °C
- Ambient temperature operation 1 - -30 °C … +55 °C with heater version O30
- Cold start temperature - -10 °C
- Storage temperature - -30 °C … +70 °C
- Temperature note 1 - The O30 version is only available for the AC version devices !
- Temperature note 2 - Operating temperature +55 °C for a maximum of 5 h, for constant operation (24/7) +50 °C.
- Temperature note 3 - Cold start temperature: If the HMI device is switched on at a temperature below -10 °C the display will need a certain amount of time to warm up until everything is clearly visible. Depending on how low the temperature is, this process may last up to 3 hours.
- Temperature note general - The temperature details apply to a standard device combination with display, keyboard and enclosure. Any additional built-in or added components may have an impact on / change these.
Components
- Keyboard - optional, 107 keys with trackball / joystick / mouse / touchpad (Ex ia)
Display
- Backlight - LED Technology
- Backlight service life - 50 000 h at +20 °C
- Display brightness - 250 cd/m²
- Display contrast - 1000:1
- Display dimensions - 16:10
- Display resolution - WSXGA+
- Display size centimetres - 56
- Display size inch - 22
- Display version - TFT Colour display
- Display version 2 - 16.7 million colours
- Front plate (display) - Aluminium
- Total pixels - 1680 x 1050
- Touch screen - optional, resistive
- Touch screen technology - 5-wire glass or membrane touch
Electrical Data
- Connection compartment - Power supply direct in integrated Ex e connection box
- Connections - via screw terminals, green
- Data cable - 50/125 μm FO cable or 62.5/125 μm FO cable
- Data cable length - max. 550 m, with 50 μm FO cable max. 300 m, with 62.5 μm FO cable
- Ethernet / Data - FO multi-mode
- Frequency range - 50 - 60 Hz
- Interface Audio - 1 x Audio Line in / out (Ex e)
- Interface medium - Multi-mode optical fibre cable
- Interface Serial - 1 x RS-232 (Ex e)
- Interface USB - 2 x USB (Ex ia) 1 x USB (Ex e) 2 x USB (Ex ia) (keyboard, pointing device)
- Max. input voltage Um - 250 VAC
- Plug version FO - LC duplex connector
- Power consumption AC 1 - 1 A
- Power consumption DC - 3 A
- Protection fuse AC - 5 AT
- Protection fuse DC - 5 AT
- Rated operational power - typically 50 W / 100 W at O30 / max. 150 W (typically 170 BTU / 341 BTU at O30 / max. 510 BTU)
- Rated operational voltage AC - 230 V
- Rated operational voltage DC - 24 V
- Transfer technology - KVM-DVI3
- Voltage range AC - 100 - 240 V
- Voltage range DC - 20 - 30 V
- Wiring - flexible cable up to 2.5 mm² (AWG14) fixed cable up to 4 mm² (AWG12)
- WLAN - optional via USB
Explosion Protection
- Application range (divisions) - Class I, Division 2
- Application range (zones) - 1 2 21 22
- Certification ATEX - BVS 11 ATEX E 102 X
- Certification CEC - 70011698
- Certification EAC - TC RU C-DE.ГБ04.B00478
- Certification IECEx - IECEx TUR 11.0075X
- Certification KCC - yes
- Certification KGS - 12-GA4BO-0617X
- Certification NEC - 70011698
- Certification note - The certificates and explosion protection markings apply to a standard device combination with display, keyboard and enclosure. Any additional built-in or added components may have an impact on / change these.
- Certifications - ATEX, IECEx, NEC, CEC, EAC, KGS
- Dust explosion protection ATEX - II 2(1) D Ex tb IIIC [ia op is Da] IP65 T110°C Db
- Dust explosion protection EAC - Ex tb IIIC [ia op is Da] IP65 T110°C Db
- Dust explosion protection IECEx - Ex tb IIIC [ia op is Da] IP65 T110°C Db
- Explosion protection CEC - Ex e q [ia] IIC T4 Gb Class I, Division 2
- Explosion protection KGS - Ex e q IIC T4 Ex tb IIIC IP64 T110°C Ex ia IIC T4 Ex ia IIIB T110°C
- Explosion protection NEC - Class I, Zone 1 AEx e q [ia] IIC T4 Gb
- Gas explosion protection ATEX - II 2(1) G Ex e q [ia op is Ga] IIC T4 Gb
- Gas explosion protection EAC - 1Ex e q [ia op is Ga] IIC T4 Gb X
- Gas explosion protection IECEx - Ex e q [ia op is Ga] IIC T4 Gb
General
- Functional Description - The OS ET-667-DVI3 HMI series includes KVM operator stations for zones 1, 2, 21, 22 and Division 2. Their brilliant 22" widescreen displays with a resolution of 1680 x 1050 pixels (format 16:10), and are available with or without touch screen. The stainless steel enclosures (SS304 or SS316L) are available with a front opening or in cleanroom-compliant design and with different mounting options. Country-specific keyboards, pointer instruments and RFID and barcode scanners are useful accessories making work easier and extending functionality. Data is transmitted via multi-mode fibre optic up to 550 m.
- Highlights - KVM Operator Station, 22" display, 1680 x 1050 Zone 1, 2, 21, 22 and Division 2 Display of the 19" (1280 x 1024) resolution true to 5:4 format Optional resistive glass or foil touch screen Data transmission via multi-mode fibre optic up to 550 m
- HMI type - Operator station
- Product description - 22" KVM system
- Product Description - KVM system SERIES 600 Device platform MANTA
- Product Type - OS ET-667-DVI3-MM
- Series - Product Series OS ET-667
- Technology - Remote HMI KVM
- WebCode - ET667A
Mechanical Data
- Breather - optional
- Dimensions (WxHxD) - 740 mm x 872 mm x 400 mm
- Ingress protection - IP66
- Keyboard note - With a keyboard with trackball, the operator station’s ingress protection is reduced to IP54, when the trackball is moved.
- Material back - Stainless steel
- Material front - Aluminium / stainless steel
- Mechanical data note - The mechanical data apply to an FR enclosure with display and keyboard. Other enclosure types as well as any additional built-in or added components may have an impact on / change these.
- Weight - 64.5 kg
Mounting / Installation
- Enclosure type - Stainless steel enclosure (FR) optional clean room (CFR)
- Mounting option - Wall, elbow, stand
1 - 1 of 1 Part Numbers