Yodify Product Library
Instantly add the LTR53 Radar Level Sensor and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
LTR53 Radar Level Sensor
Brand: Intempco Controls, IncWhen the LTR53 series radar is turned ON in a system having a clean separation between oil and water (no water droplets in the oil) , the radar gets a reflection from the oil-water interface that gives current output proportional to the oil-water interface level.
The echo from the oil-water interface is masked and the radar is forced to go to higher power to detect echo from top of oil.
The output current alternates between oil level and oil-water interface level. Special parameter in software changes alternating time between the two level output signals.
If water is present in the oil the radar does not penetrate oil and shows the current output proportional to the top of oil.
When heat is applied and separation happens the radar starts showing two current values; one from top of oil and another one from oil-water interface.
Features- Explosion proof for Class I, Division 1, Groups B, C, D
- Self adjusting tracking radar ideal for oil-water interface detection
- Programmable calibration
- Output 4-20 mA/20-4 mA
- Output sequences between interface level and oil level
- Optional RS232, RS485 for communications with calibration, diagnostics and data logging software
- PLC compatible (Modbus RTU)
- 3-wire DC
1 - 1 of 1 Part Numbers
LTR53
- Supply Voltage - 12-30 Vdc (0.07 A Maximum at 24 Vdc)
- Output - 4-20 mA/20-4 mA
- Measurement Range - 17 feet (5 meters)
- Enclosure Type - Aluminum, 1/2" NPT x 2 Conduit
- Process Connection - 1-1/2" Male NPT
- Communication - RS-232
- Antenna - Polypropylene Rod
- Options - Without Options
1 - 1 of 1 Part Numbers
Specifications
Brand
Accuracy
- ± 0.1 % of, Max.
- ± 0.25 % of, Max.
- Loop Powered Display: ± 0.5 % of Reading
Approvals & Certifications
- FCC Part 15 - Low Power Communication Device
Calibration
- Via Communication Software Provided with Units
Class
- Installation Category: Class II
Communication
- Modbus RTU
- RS-232
- RS-485
Conduit Connection
- Conduit Entry: 1/2” NPT
Cover Material
- Threaded Wiring Access Cover: Aluminum
- Threaded Wiring Access Cover: Stainless Steel
Diagnostics
- (Echo Profile) Via Communications Port
Display
- Head Mounted LCD Display
- Loop Powered Display: 4-1/2-Digit LCD 1/2” High
Enclosure, Body Material
- Aluminum
- Stainless Steel
Environmental Protection
- Explosion-proof for Class I, Div. 1, Groups B, C, D
- IP67
- NEMA 6
Frequency
- 5.8 to 6.3 GHz
Humidity
- 0 to 95 % Non-Condensing
Length
- Antenna Extension: 6” (150 mm) with Teflon Antennas Only
- Antenna Extension: 8” (203.2 mm) with Teflon Antennas Only
Materials of Construction
- Antenna: Polypropylene Rod
- Antenna: Teflon Rod
- Horn Antenna: 316L Stainless Steel
Measuring Range
- 17 to 240 feet (5 to 73 metres)
- Measure Interface: 5” (127 mm)
NPT Connection
- 1-1/2” NPT Male
- 2” NPT Male
- 3” NPT Male
Output
- 20-4 mA
- 3-Wire with 12-30 Vdc Power
- 4-20 mA
Power
- Transmit: 50 µW Average
Power Supply
- 12-30 Vdc, 0.07 A, Max.
Pressure Range
- bar: 0 to 5
- kPa: 0 to 500
- psi: 0 to 72.52
Principle of Operation
- Pulse Radar
Process Temperature
- De-Coupler & PTFE Rod: -40° to 204° C (-40° to 400° F)
- PP Rod: -40° to 60° C (-40° to 140° F)
Range
- Loop Powered Display: 3.5-22 mA
Resolution
- ± 0.079” (2 mm)
- 0.08 to 1.06” (2 to 26 mm)
- Output: 6.1 µA
Response Time
- Fast Protocol Unit: 10 to 30 Echo’s/second
- Standard Unit: 2 to 3 Echo's/second
- Standard with Less Damping: 6 Echo's/second
Temperature Range
- -40° to 60° C (-40° to 140° F)
Voltage Drop
- Loop Powered Display: 0.95 V at 20 mA