EC80 Flow Processor
Brand: Cox InstrumentsThe Cox EC80 Flow Processor is a programmable electronic processor, providing total compensation to enhance flow meter accuracy, while extending the linear flow range.
Packaging is provided for remote, direct or embedded mounting to support most installation or application requirements. The compact design includes both single and dual frequency inputs from 4 or 10 ohms pickups, as well an RTD input and an additional Analog input for other temperature inputs.
The EC80 processor tracks all variables to compensate for viscous and inertial effects, using proven Strouhal-Roshko algorithms. Enhanced DSP technology allows for exceptional signal characterization using a 32-bit floating point processor at 150 MHz, capable of producing a 100 microsecond speed of response.
Features- Rotor blade pulse averaging
- Strouhal-Roshko computation, using 16-bit resolution
- Dual outputs provide both frequency and Analog signals
- Recallable and stored calibration data
- Internal amplifier and signal conditioners
- Assignable outputs
Specifications
Brand
Applications
- Control Loops
- Custom OEM Flight & Commercial Applications
- Engine Test Cells & Test Stands
- On-Board Automotive & Aerospace Testing
- Precision Monitoring
Cable Length
- Remote (EC80 to DAQ or Control System): 100 feet (30.5 metres)
- Remote (Flow Meter to EC80): 20 feet (6.1 metres)
Communication
- EIA-485
- EIA-485 Serial Data - Baud Rate: 115 K
- EIA-485 Serial Data - Data Bit: 8-bit
- EIA-485 Serial Data - Stop Bit: 1-bit
Duty Cycle
- Frequency Output: 50 %
Enclosure, Body Material
- Remote & Remote with Display: Aluminum
Environmental Protection
- IP65
- IP66
- NEMA 4
Frequency
- 0-5 V, TTL, Frequency Output 1 to 20,000 Hz, Square Wave
- Flow Meter Input Typical A & B (Pulse TTL Compatible & RF Carrier): 5 to 5,000 Hz
- Flow Meter Input Typical A & B (RF Carrier): 25 to 65 kHz
- Raw Frequency Output: 5 to 3,500 Hz
Function
- Bi-Directional Flow Capability
Humidity
- 0 to 80 % Relative Humidity, Non-Condensing
Input
- Analog Input: 0-10 Vdc
- Analog Input: 0-5 V
Input Impedance
- Analog Input: > 100 kiloohms
Input Power
- Nominal: 24 Vdc at 2 W, Max.
- With Analog Output: 12-32 Vdc
- With Digital Output: 7-32 Vdc
Linearization
- Performance (Linearized Analog Output): ± 0.1 % of Full Scale
- Performance (Linearized Frequency): ± 0.1 % of Reading
Load Impedance
- Analog Output (4-20 mA): 500 ohms, Max.
- Frequency Output: 10 kiloohms Min.
Load Resistance
- Raw Frequency Output: 5 kiloohms Min.
Materials of Construction
- Blind Integral: Cast Aluminum
Operating Temperature
- -40° to 85° C (-40° to 185° F)
Output
- Analog Output (Channel One): 4-20 mA
- Analog Output: 0-10 Vdc
- Analog Output: 0-5 Vdc
Resistance
- Flow Meter Input Typical A & B (RF Carrier): 10 ohms Pickup
- Flow Meter Input Typical A & B (RF Carrier): 4 ohms Pickup
Resolution
- Analog Input (ADC Resolution): 12-bit (1/4096)
- Analog Output: 16-bit
Response Time
- 100 µs
RTD Type
- RTD Temperature Input (4-Wire): 100 ohms Platinum, 0.00385 Alpha
Storage Temperature
- -55° to 125° C (-67° to 257° F)
Temperature Range
- RTD Temperature Input (4-Wire): -55° to 185° C (-65° to 365° F)