Yodify Product Library
Add the Sono 1500 CT Ultrasonic Flow Sensor to your store or catalog  
Book Your Demo and See How
or create your store

Sono 1500 CT Ultrasonic Flow Sensor

Brand: Danfoss

The SONO 1500 CT is an ultrasonic flow sensor especially designed for heating, cooling or combined heating/cooling application in local and district energy systems. 

The SONO 1500 CT has been approved according to MID in class 2 and 3.
Features
  • 1st approval in Europe for ultrasonic flow sensor with dynamic range of qi /qp 1:250 in class 2 (qp 1.5 / 2.5 / 6 / 10 / 15 / 25 / 40 / 60 m³/hr)
  • Complete dynamic range: ≥1:1500
  • Lithium battery with a lifetime of 11 years or external supply
  • Temperature range: 5° to 90° C / 130° C / 150° C
  • Overload temperature up to 150° C (sizes qp 0.6 up to 2.5 m³/hr)
  • Available in nominal sizes: qp 0.6 / 1.0 / 1.5 / 2.5 / 3.5 / 6 / 10 / 15 / 25 / 40 / 60 m³/hr
  • Unique free-beam principle
  • Swirl-free flow around reflector
  • Robust stainless steel reflector
  • All sizes also available in PN 25
  • No calming sections necessary in the inlet and / or outlet (standard installation)
  • NOWA test capability
  • Connection to calculator with pulse defined values
  • Insensitive against magnetite
  • Installation in any position
  • Free selectable pulse values

1 - 12 of 14 Part Numbers
087G
087G
  • Flow Sensor - qp 0.6 m³/hour / 110 mm Thread / DN 15 / G 3/4" B / 1 Liter/Pulse
  • Nominal Pressure - PN 16
087G1350
087G1350
  • Flow Sensor - qp 0.6 m³/hour / 110 mm Thread / DN 15 / G 3/4" B / 1 Liter/Pulse
  • Nominal Pressure - PN 16
  • Cable Length - 2.5 metres
087G1351
087G1351
  • Flow Sensor - qp 1.5 m³/hour / 110 mm Thread / DN 15 / G 3/4" B / 1 Liter/Pulse
  • Nominal Pressure - PN 16
  • Cable Length - 2.5 metres
087G1352
087G1352
  • Flow Sensor - qp 1.5 m³/hour / 130 mm Thread / DN 20 / G 1" B / 1 Liter/Pulse
  • Nominal Pressure - PN 16
  • Cable Length - 2.5 metres
087G1353
087G1353
  • Flow Sensor - qp 2.5 m³/hour/ 130 mm Thread / DN 20 / G 1" B / 1 Liter/Pulse
  • Nominal Pressure - PN 16
  • Cable Length - 2.5 metres
087G1354
087G1354
  • Flow Sensor - qp 3.5 m³/hour / 260 mm Thread / DN 25 / G1-1/4" B / 10 Liter/Pulse
  • Nominal Pressure - PN 25
  • Cable Length - 2.5 metres
087G1355
087G1355
  • Flow Sensor - qp 6 m³/hour / 260 mm Thread / DN 25 / G1-1/4" B / 10 Liter/Pulse
  • Nominal Pressure - PN 25
  • Cable Length - 2.5 metres
087G1356
087G1356
  • Flow Sensor - qp 10 m³/hour / 300 mm Thread / DN 40 / G 2" B / 10 Liter/Pulse
  • Nominal Pressure - PN 25
  • Cable Length - 2.5 metres
087G1357
087G1357
  • Flow Sensor - qp 6 m³/hour / 260 mm Flange DN 32 / 10 Liter/Pulse
  • Nominal Pressure - PN 25
  • Cable Length - 2.5 metres
087G1358
087G1358
  • Flow Sensor - qp 10 m³/hour / 300 mm Flange DN 40 / 10 Liter/Pulse
  • Nominal Pressure - PN 25
  • Cable Length - 2.5 metres
087G1359
087G1359
  • Flow Sensor - qp 15 m³/hour / 270 mm Flange DN 50 /10 Liter/Pulse
  • Nominal Pressure - PN 25
  • Cable Length - 5 metres
087G1360
087G1360
  • Flow Sensor - qp 25 m³/hour / 300 mm Flange DN 65 / 10 Liter/Pulse
  • Nominal Pressure - PN 25
  • Cable Length - 5 metres
1 - 12 of 14 Part Numbers

Specifications

Brand

Approvals & Certifications

  • EN 1434 Class C
  • CE
  • MID: DE-09-MI004-PTB011, Class 2 & 3

Battery Life

  • 11-Years

BSP Connection

  • G 1" B Female
  • G 1-1/4" B Female
  • G 2" B Female
  • G 3/4" B Female
  • 1" BSPT Male
  • 1/2" BSPT Male
  • 1-1/2" BSPT Male
  • 3/4" BSPT Male

Cable Length

  • Cable Length of Flow Sensor: 16.40 ft (5 m)
  • Cable Length of Flow Sensor: 8.2 ft (2.5 m)

Current

  • Impulse Current: < 10 mA

Environmental Protection

  • IP54 (Heating)
  • IP65 (Cooling)

Flange Size - 1-1/2” (DN 40)

  • 1-1/2" (DN 40) - PN 25

Flange Size - 1-1/4” (DN 32)

  • 1-1/4" (DN 32) - PN 25

Flange Size - 1” (DN 25)

  • 1" (DN 25) - PN 25

Flange Size - 2-1/2” (DN 65)

  • 2-1/2" (DN 65) - PN 25

Flange Size - 2” (DN 50)

  • 2" (DN 50) - PN 25

Flange Size - 3” (DN 80)

  • 3" (DN 80) - PN 25

Flange Size - 3/4” (DN 20)

  • 3/4" (DN 20) - PN 25

Flange Size - 4” (DN 100)

  • 4" (DN 100) - PN 25

Flow Rate

  • Maximum
  • Nominal: 0.6 to 60 m³/hour
  • Standard & Extended Min.: 6 to 600 L/hr
  • Starting: 1 to 120 L/hr

Frequency

  • Output Frequency of Battery Supply: ≤ 20 Hz
  • Output Frequency of External Supply: ≤ 150 Hz

Humidity

  • Maximum

Length

  • 4.33" to 14.17" (110 to 360 mm)

Materials of Construction

  • Reflector: Stainless Steel

Media

  • Circulation Water, pH: 7 to 10

Mounting Position

  • Any Orientation

Nominal Pressure

  • psi: 232.1 (kPa: 1,600, bar: 16)
  • psi: 362.6 (bar: 25, kPa: 2,500)

Operating Pressure

  • psi: 232.1 (kPa: 1,600, bar: 16)
  • psi: 362.6 (kPa: 2,500, bar: 25)

Operating Temperature

  • Ambient Operating Temperature: 5° to 55° C (41° to 131° F)

Output

  • Pulse: Open Collector

Power Consumption

  • < 130 mAh Per Year

Pulse Range

  • 1 to 250 ms ± 10 % Pulse Duration ≤ Pulse Pause

Sensor / Probe Style

  • Ultrasonic Flow Sensor

Storage Temperature

  • Ambient Storage Temperature: -25° to 55° C (-13° to 131° F)

Supply Voltage

  • Operating Battery Supply: 3 Vdc
  • Operating External Supply: 3-5.5 Vdc

Temperature Range

  • Temperature Range Cooling External Supplied: 5° to 120° C (41° to 248° F)
  • Temperature Range Heating & Cooling Battery Supplied: 5° to 105° C (41° to 221° F)
  • Temperature Range Heating External Supplied: 5° to 150° C (41° to 302° F)

  • Heating, cooling or combined heating/cooling application in local and district energy systems

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more