Yodify Product Library
Instantly add the Cable Glands Ex e & Ex nR & Ex ta Series C2KX and 50,000+ more product series to yourĀ store or catalogĀ Ā
Book Your Demo and See How
or create your store
Cable Glands Ex e & Ex nR & Ex ta Series C2KX
Brand: R. STAHL AGSpecial version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armored cables, i.e. for SWA, braid- and tape-type steel and aluminium armoring.
They feature a multi-functional holder for the armoring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
Features- Designed for use in North America
- Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
- Safety provided by flood seal with integral protection and controlled outer load retention sea
- Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
- Worldwide certification: UL, cCSAus, ATEX and IECEx
1 - 12 of 21 Part Numbers
243569
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-20S16-C2KX-1/2
- Title Product Variant Technical Data - CMP-20s/16C2KX gland NB NPT 1/2"
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.00 mm
- Armour wire thickness min. - 0.30 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 6.10 - 13.20 mm
- Clamping range max. - 13.20 mm
- Clamping range min. - 6.10 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 20s/16
- Grooved cone - 0.30 … 1.00 mm
- Inner sheath - 8.60 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 6.10 … 13.20 mm
- Protrusion length - 65.00 mm
- PVC-shroud - PVC06
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.30 … 1.00 mm
- Thread length - 19.900 mm
- Thread pitch - 14 TPI
- Thread size - NPT1/2
- Thread standard - NPT
- Weight - 0.520 kg
- Width across corners - 33.50 mm
- Width across flats - 30.50 mm
243570
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-20S-C2KX-1/2
- Title Product Variant Technical Data - CMP-20sC2KX gland NB NPT 1/2"
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.00 mm
- Armour wire thickness min. - 0.30 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 9.40 - 16.00 mm
- Clamping range max. - 16.00 mm
- Clamping range min. - 9.40 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 20s
- Grooved cone - 0.30 … 1.00 mm
- Inner sheath - 11.70 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 9.40 … 16.00 mm
- Protrusion length - 62.00 mm
- PVC-shroud - PVC06
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.30 … 1.00 mm
- Thread length - 19.900 mm
- Thread pitch - 14 TPI
- Thread size - NPT1/2
- Thread standard - NPT
- Weight - 0.520 kg
- Width across corners - 33.50 mm
- Width across flats - 30.50 mm
243571
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-20-C2KX-1/2
- Title Product Variant Technical Data - CMP-20C2KX gland NB NPT 1/2"
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.00 mm
- Armour wire thickness min. - 0.40 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 12.40 - 20.80 mm
- Clamping range max. - 20.80 mm
- Clamping range min. - 12.40 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 20
- Grooved cone - 0.40 … 1.00 mm
- Inner sheath - 14.00 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 12.40 … 20.80 mm
- Protrusion length - 63.00 mm
- PVC-shroud - PVC06
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.40 … 1.00 mm
- Thread length - 19.900 mm
- Thread pitch - 14 TPI
- Thread size - NPT1/2
- Thread standard - NPT
- Weight - 0.520 kg
- Width across corners - 33.60 mm
- Width across flats - 30.50 mm
243572
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-25-C2KX-3/4
- Title Product Variant Technical Data - CMP-25C2KX gland NB NPT 3/4"
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.20 mm
- Armour wire thickness min. - 0.40 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 18.30 - 26.20 mm
- Clamping range max. - 26.20 mm
- Clamping range min. - 18.30 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 25
- Grooved cone - 0.40 … 1.20 mm
- Inner sheath - 20.10 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 18.30 … 26.20 mm
- Protrusion length - 69.60 mm
- PVC-shroud - PVC09
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.40 … 1.20 mm
- Thread length - 20.200 mm
- Thread pitch - 14 TPI
- Thread size - NPT3/4
- Thread standard - NPT
- Weight - 0.520 kg
- Width across corners - 41.10 mm
- Width across flats - 37.50 mm
243573
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-32-C2KX-1
- Title Product Variant Technical Data - CMP-32C2KX gland NB NPT 1"
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.20 mm
- Armour wire thickness min. - 0.40 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 23.60 - 34.00 mm
- Clamping range max. - 34.00 mm
- Clamping range min. - 23.60 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 32
- Grooved cone - 0.40 … 1.20 mm
- Inner sheath - 25.90 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 23.60 … 34.00 mm
- Protrusion length - 74.90 mm
- PVC-shroud - PVC11
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.40 … 1.20 mm
- Thread length - 25.000 mm
- Thread pitch - 11,5 TPI
- Thread size - NPT1
- Thread standard - NPT
- Weight - 0.520 kg
- Width across corners - 50.50 mm
- Width across flats - 46.00 mm
243575
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-50S-C2KX-1 1/2
- Title Product Variant Technical Data - CMP-50SC2KX gland NB NPT 1 1/2"
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.60 mm
- Armour wire thickness min. - 0.40 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 35.30 - 46.70 mm
- Clamping range max. - 46.70 mm
- Clamping range min. - 35.30 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 50s
- Grooved cone - 0.40 … 1.60 mm
- Inner sheath - 38.10 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 35.30 … 46.70 mm
- Protrusion length - 77.00 mm
- PVC-shroud - PVC18
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.40 … 1.60 mm
- Thread length - 26.100 mm
- Thread pitch - 11,5 TPI
- Thread size - NPT1-1/2
- Thread standard - NPT
- Weight - 0.860 kg
- Width across corners - 66.00 mm
- Width across flats - 60.00 mm
243576
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-50-C2KX-2
- Title Product Variant Technical Data - CMP-50C2KX gland NB NPT 2"
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.60 mm
- Armour wire thickness min. - 0.60 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 40.40 - 53.10 mm
- Clamping range max. - 53.10 mm
- Clamping range min. - 40.40 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 50
- Grooved cone - 0.60 … 1.60 mm
- Inner sheath - 44.20 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 40.40 … 53.10 mm
- Protrusion length - 77.00 mm
- PVC-shroud - PVC21
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.60 … 1.60 mm
- Thread length - 26.900 mm
- Thread pitch - 11,5 TPI
- Thread size - NPT2
- Thread standard - NPT
- Weight - 1.130 kg
- Width across corners - 77.20 mm
- Width across flats - 70.10 mm
243577
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-63S-C2KX-2
- Title Product Variant Technical Data - CMP-63SC2KX gland NB NPT 2"
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.60 mm
- Armour wire thickness min. - 0.60 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 45.70 - 59.40 mm
- Clamping range max. - 59.40 mm
- Clamping range min. - 45.70 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 63s
- Grooved cone - 0.60 … 1.60 mm
- Inner sheath - 50.00 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 45.70 … 59.40 mm
- Protrusion length - 80.00 mm
- PVC-shroud - PVC23
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.60 … 1.60 mm
- Thread length - 26.900 mm
- Thread pitch - 8 TPI
- Thread size - NPT2
- Thread standard - NPT
- Weight - 1.330 kg
- Width across corners - 82.60 mm
- Width across flats - 75.00 mm
243578
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-63-C2KX-2 1/2
- Title Product Variant Technical Data - CMP-63C2KX gland NB NPT 2 1/2"
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.60 mm
- Armour wire thickness min. - 0.60 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 54.60 - 65.80 mm
- Clamping range max. - 65.80 mm
- Clamping range min. - 54.60 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 63
- Grooved cone - 0.60 … 1.60 mm
- Inner sheath - 56.10 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 54.60 … 65.80 mm
- Protrusion length - 80.00 mm
- PVC-shroud - PVC25
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.60 … 1.60 mm
- Thread length - 39.900 mm
- Thread pitch - 8 TPI
- Thread size - NPT2-1/2
- Thread standard - NPT
- Weight - 1.340 kg
- Width across corners - 88.10 mm
- Width across flats - 80.00 mm
243579
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-75S-C2KX-2 1/2
- Title Product Variant Technical Data - CMP-75SC2KX gland NB NPT 2 1/2"
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.60 mm
- Armour wire thickness min. - 0.60 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 58.90 - 72.10 mm
- Clamping range max. - 72.10 mm
- Clamping range min. - 58.90 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 75s
- Grooved cone - 0.60 … 1.60 mm
- Inner sheath - 62.00 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 58.90 … 72.10 mm
- Protrusion length - 87.10 mm
- PVC-shroud - PVC28
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.60 … 1.60 mm
- Thread length - 39.900 mm
- Thread pitch - 8 TPI
- Thread size - NPT2-1/2
- Thread standard - NPT
- Weight - 2.020 kg
- Width across corners - 99.10 mm
- Width across flats - 90.00 mm
243580
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-75-C2KX-3
- Title Product Variant Technical Data - CMP-75C2KX gland NB NPT 3"
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.60 mm
- Armour wire thickness min. - 0.60 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 66.80 - 78.50 mm
- Clamping range max. - 78.50 mm
- Clamping range min. - 66.80 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 75
- Grooved cone - 0.60 … 1.60 mm
- Inner sheath - 64.30 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 66.80 … 78.50 mm
- Protrusion length - 88.10 mm
- PVC-shroud - PVC30
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.60 … 1.60 mm
- Thread length - 41.500 mm
- Thread pitch - 8 TPI
- Thread size - NPT3
- Thread standard - NPT
- Weight - 2.480 kg
- Width across corners - 110.00 mm
- Width across flats - 100.00 mm
243581
Designed for use in North America
Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring
Safety provided by flood seal with integral protection and controlled outer load retention sea
Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD
Worldwide certification: UL, cCSAus, ATEX and IECEx
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1070 X
- ATEX gas certificate - SIRA 13 ATEX 1070 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4076 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - III 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Gas explosion protection ATEX - II 2 G Ex e IIC Gb
- Gas explosion protection EAC - 1 Ex e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex e IIC Gb
- IECEX dust certificate - IECEx SIR 13.0025 X
- IECEX gas certificate - IECEx SIR 13.0025 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
General
- Functional Description - Special version for the North American market. C2KX series metal Ex e cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel and aluminium armouring Safety provided by flood seal with integral protection and controlled outer load retention sea Class I Zone 1, 21 and Zone 2, 22 Class I Div. 2 groups ABCD Worldwide certification: UL, cCSAus, ATEX and IECEx
- Product Description - Cable gland
- Product Type - CMP-20S16-C2KX
- Title Product Variant Technical Data - CMP-20s/16C2KX gland NB M20
- WebCode - C2KXA
Mechanical Data
- Armour wire thickness max. - 1.00 mm
- Armour wire thickness min. - 0.30 mm
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Clamping range - 6.10 - 13.20 mm
- Clamping range max. - 13.20 mm
- Clamping range min. - 6.10 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 20s/16
- Grooved cone - 0.30 … 1.00 mm
- Inner sheath - 8.60 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Outer sheath - 6.10 … 13.20 mm
- Protrusion length - 65.00 mm
- PVC-shroud - PVC06
- Sealing material - SOLO LSF
- Silicone-free - Yes
- Stepped cone - 0.30 … 1.00 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M20
- Thread standard - metric
- Weight - 0.520 kg
- Width across corners - 33.50 mm
- Width across flats - 30.50 mm
1 - 12 of 21 Part Numbers