Yodify Product Library
Instantly add the GW55 Guided Wave Radar Level Instrument and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
GW55 Guided Wave Radar Level Instrument
Brand: BM TechnologiesGW55 for liquids Applications: Level measurement in liquids, suitable for critical environments, to high temperature and high pressure.
The microwaves impulses at high frequency travel through a stainless steel guide and they are reflected on the surface of the fluid to analyze.
The period of time that passes between the emission of the impulses and their reception is proportional to the distance between the surface of the fluid and the plan of reference of the instrument.
BM COMPACT GW55 series is supplied with the advanced microprocessor echo discovery, it can be used in very different environmental conditions.
1 - 1 of 1 Part Numbers
GW55
- Type of Detecting Component / Material - Rope / AISI 316L Stainless Steel / Ceramic
- Process Connection - Thread G 1-1/2" A
- Electronics - 4-20 mA HART 2-Wires
- Housing Material / Protection Class - Plastic / IP66
- Operating Temperature - -200° to 400° C
- Wiring - M20 x 1.5
- Display / Programming - YES
1 - 1 of 1 Part Numbers
Specifications
Brand
Accuracy
- ± 10 mm
Applications
- Level Measurement of Liquid & Solid
BSP Connection
- Antenna: G 1-1/2” A
- G 2” A
Cable Entry
- 1 x PG 13.5
Communication
- Output Signal: HART
Consumption
- Absorption: Max.
Current
- Fixed Signal for Anomaly: 20.5 mA
- Fixed Signal for Anomaly: 22 mA
- Fixed Signal for Anomaly: 3.6 mA
Display
- Resolution Display: 0.039” (1 mm)
Electrical Connectors
- 1/2” NPT
- M20 x 1.5
Enclosure, Body Material
- AISI 316L Stainless Steel
- Aluminum
- Plastic PBT-FR
Environmental Protection
- IP66
- IP67
Frequency
- Resistance to Vibration: 10 to 150 Hz
- Ripple Allowed: 100 to 10,000 Hz
Humidity
- < 95 % Relative Humidity
Input
- Input Voltage: 15-36 Vdc for Supply 2-Wires Version
- Input Voltage: 230 Vac ± 10 % for Supply 4-Wires Version
- Input Voltage: 24 Vdc ± 10 % for Supply 4-Wires Version
Materials of Construction
- Pole: AISI 316L Stainless Steel
- Pole: Ceramic
- Polypropylene
Measuring Range
- Maximum
Measuring Time
- Interval of Measuring: Approximately 1 second
NPT Connection
- Antenna: 1-1/2” NPT Male
Operating Temperature
- -200° to 400° C (-328° to 752° F)
Output
- 4-20 mA, 2 or 4-Wires
Pressure Range
- bar: -1 to 40
- kPa: -100 to 4,000
- psi: -14.5 to 580
Resistance
- Maximum
Resolution
- 6 µA
Seat / Seal Material
- Seal: Kalrez
- Seal: Viton
Sensor, Probe Material
- AISI 316L Stainless Steel
- Ceramic
Storage Temperature
- -40° to 80° C (-40° to 176° F)
Update Time
- Integration Time: 0 to 999 seconds
- Interval of Updating: Approximately 1 second