Brand: R. STAHL AG

The 6009 series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. 

The battery is housed in the external enclosure and powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the central lock is opened, the luminaire is always disconnected from the power supply at all poles.
Features
  • Can be used in Ex Zones 1, 2, 21 and 22
  • Two fluorescent lamps: 18 W and 36 W
  • Weekly function test and annual emergency light duration test

1 - 9 of 9 Part Numbers
225723
225723
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 1, 2, 21 and 22

Two fluorescent lamps: 18 W and 36 W

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043-792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2015
  • ATEX gas certificate - PTB 13 ATEX 2015
  • Certificate EAC - TS RU S-DE.GB04.B.00264
  • Certificates - ATEX (PTB), Brazil (ULB), China (CQST), EAC (STV), IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80°C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de mb IIC T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb IIC T4 Gb
  • Gas explosion protection IECEx - Ex de mb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 13.0059
  • IECEX gas certificate - IECEx PTB 13.0059
  • Languages of the documentation - Brazil, English, French, German, Russian, Spanish
  • Note: Through wiring - max. 3x16 A
  • Ship approval - BVIS, DNVGL

General

  • Functional Description - The 6009 series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The battery is housed in the external enclosure and powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the central lock is opened, the luminaire is always disconnected from the power supply at all poles.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Two fluorescent lamps: 18 W and 36 W Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6009/522-9617-1611-71
  • Title Product Variant Technical Data - 6009/522-9617-1611-71 emerg.light 2x18W
  • WebCode - 6009A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Lamp wattage - 18 W
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Lighting lock - Central lock , For box spanner actuation
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 7.600 kg
  • Width - 183.500 mm
225725
225725
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 1, 2, 21 and 22

Two fluorescent lamps: 18 W and 36 W

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043-792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 36 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2015
  • ATEX gas certificate - PTB 13 ATEX 2015
  • Certificate EAC - TS RU S-DE.GB04.B.00264
  • Certificates - ATEX (PTB), Brazil (ULB), China (CQST), EAC (STV), IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80°C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de mb IIC T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb IIC T4 Gb
  • Gas explosion protection IECEx - Ex de mb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 13.0059
  • IECEX gas certificate - IECEx PTB 13.0059
  • Languages of the documentation - Brazil, English, French, German, Russian, Spanish
  • Note: Through wiring - max. 3x16 A
  • Ship approval - BVIS, DNVGL

General

  • Functional Description - The 6009 series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The battery is housed in the external enclosure and powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the central lock is opened, the luminaire is always disconnected from the power supply at all poles.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Two fluorescent lamps: 18 W and 36 W Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6009/542-9617-1611-71
  • Title Product Variant Technical Data - 6009/542-9617-1611-71 emerg.light 2x36W
  • WebCode - 6009A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Lighting lock - Central lock , For box spanner actuation
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.650 kg
  • Width - 183.500 mm
238147
238147
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 1, 2, 21 and 22

Two fluorescent lamps: 18 W and 36 W

Weekly function test and annual emergency light duration test
238148
238148
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 1, 2, 21 and 22

Two fluorescent lamps: 18 W and 36 W

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043-792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x SS430 stainless steel
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2015
  • ATEX gas certificate - PTB 13 ATEX 2015
  • Certificate EAC - TS RU S-DE.GB04.B.00264
  • Certificates - ATEX (PTB), Brazil (ULB), China (CQST), EAC (STV), IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80°C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de mb IIC T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb IIC T4 Gb
  • Gas explosion protection IECEx - Ex de mb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 13.0059
  • IECEX gas certificate - IECEx PTB 13.0059
  • Languages of the documentation - Brazil, English, French, German, Russian, Spanish
  • Note: Through wiring - max. 3x16 A
  • Ship approval - BVIS, DNVGL

General

  • Functional Description - The 6009 series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The battery is housed in the external enclosure and powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the central lock is opened, the luminaire is always disconnected from the power supply at all poles.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Two fluorescent lamps: 18 W and 36 W Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6009/542-9617-1622-71
  • Title Product Variant Technical Data - 6009/542-9617-1622-71 emerg.light 2x36W
  • WebCode - 6009A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Lamp wattage - 36 W
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Lighting lock - Central lock , For box spanner actuation
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.600 kg
  • Width - 183.500 mm
239095
239095
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 1, 2, 21 and 22

Two fluorescent lamps: 18 W and 36 W

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043-792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x SS430 stainless steel
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 18 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2015
  • ATEX gas certificate - PTB 13 ATEX 2015
  • Certificate EAC - TS RU S-DE.GB04.B.00264
  • Certificates - ATEX (PTB), Brazil (ULB), China (CQST), EAC (STV), IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80°C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de mb IIC T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb IIC T4 Gb
  • Gas explosion protection IECEx - Ex de mb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 13.0059
  • IECEX gas certificate - IECEx PTB 13.0059
  • Languages of the documentation - Brazil, English, French, German, Russian, Spanish
  • Note: Through wiring - max. 3x16 A
  • Ship approval - BVIS, DNVGL

General

  • Functional Description - The 6009 series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The battery is housed in the external enclosure and powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the central lock is opened, the luminaire is always disconnected from the power supply at all poles.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Two fluorescent lamps: 18 W and 36 W Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6009/522-9617-2622-71
  • Title Product Variant Technical Data - 6009/522-9617-2622-71 emerg.light 2x18W
  • WebCode - 6009A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Lighting lock - Central lock , For box spanner actuation
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 7.600 kg
  • Width - 183.500 mm
239096
239096
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 1, 2, 21 and 22

Two fluorescent lamps: 18 W and 36 W

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043-792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x SS430 stainless steel
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 36 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2015
  • ATEX gas certificate - PTB 13 ATEX 2015
  • Certificate EAC - TS RU S-DE.GB04.B.00264
  • Certificates - ATEX (PTB), Brazil (ULB), China (CQST), EAC (STV), IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80°C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de mb IIC T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb IIC T4 Gb
  • Gas explosion protection IECEx - Ex de mb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 13.0059
  • IECEX gas certificate - IECEx PTB 13.0059
  • Languages of the documentation - Brazil, English, French, German, Russian, Spanish
  • Note: Through wiring - max. 3x16 A
  • Ship approval - BVIS, DNVGL

General

  • Functional Description - The 6009 series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The battery is housed in the external enclosure and powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the central lock is opened, the luminaire is always disconnected from the power supply at all poles.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Two fluorescent lamps: 18 W and 36 W Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6009/542-9617-2622-71
  • Title Product Variant Technical Data - 6009/542-9617-2622-71 emerg.light 2x36W
  • WebCode - 6009A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Lighting lock - Central lock , For box spanner actuation
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.600 kg
  • Width - 183.500 mm
239270
239270
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 1, 2, 21 and 22

Two fluorescent lamps: 18 W and 36 W

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043-792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 18 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2015
  • ATEX gas certificate - PTB 13 ATEX 2015
  • Certificate EAC - TS RU S-DE.GB04.B.00264
  • Certificates - ATEX (PTB), Brazil (ULB), China (CQST), EAC (STV), IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80°C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de mb IIC T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb IIC T4 Gb
  • Gas explosion protection IECEx - Ex de mb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 13.0059
  • IECEX gas certificate - IECEx PTB 13.0059
  • Languages of the documentation - Brazil, English, French, German, Russian, Spanish
  • Note: Through wiring - max. 3x16 A
  • Ship approval - BVIS, DNVGL

General

  • Functional Description - The 6009 series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The battery is housed in the external enclosure and powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the central lock is opened, the luminaire is always disconnected from the power supply at all poles.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Two fluorescent lamps: 18 W and 36 W Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6009/522-9617-2611-71
  • Title Product Variant Technical Data - 6009/522-9617-2611-71 emerg.light 2x18W
  • WebCode - 6009A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Lighting lock - Central lock , For box spanner actuation
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 7.600 kg
  • Width - 183.500 mm
239301
239301
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 1, 2, 21 and 22

Two fluorescent lamps: 18 W and 36 W

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6043-792-201
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 36 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 220.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2015
  • ATEX gas certificate - PTB 13 ATEX 2015
  • Certificate EAC - TS RU S-DE.GB04.B.00264
  • Certificates - ATEX (PTB), Brazil (ULB), China (CQST), EAC (STV), IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80°C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de mb IIC T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb IIC T4 Gb
  • Gas explosion protection IECEx - Ex de mb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 13.0059
  • IECEX gas certificate - IECEx PTB 13.0059
  • Languages of the documentation - Brazil, English, French, German, Russian, Spanish
  • Note: Through wiring - max. 3x16 A
  • Ship approval - BVIS, DNVGL

General

  • Functional Description - The 6009 series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The battery is housed in the external enclosure and powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the central lock is opened, the luminaire is always disconnected from the power supply at all poles.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Two fluorescent lamps: 18 W and 36 W Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6009/542-9617-2611-71
  • Title Product Variant Technical Data - 6009/542-9617-2611-71 emerg.light 2x36W
  • WebCode - 6009A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Lighting lock - Central lock , For box spanner actuation
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.600 kg
  • Width - 183.500 mm
262385
262385
R. STAHL Emergency Luminaire for Fluorescent Lamps GRP
Can be used in Ex Zones 1, 2, 21 and 22

Two fluorescent lamps: 18 W and 36 W

Weekly function test and annual emergency light duration test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 6042/782-201 (110 V to 127 V)
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 36 W
  • Rated operational voltage AC - 110.00 - 127.00 V
  • Rated operational voltage max. AC - 127.00 V
  • Rated operational voltage min. AC - 110.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2015
  • ATEX gas certificate - PTB 13 ATEX 2015
  • Certificate EAC - TS RU S-DE.GB04.B.00264
  • Certificates - ATEX (PTB), Brazil (ULB), China (CQST), EAC (STV), IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80°C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de mb IIC T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb IIC T4 Gb
  • Gas explosion protection IECEx - Ex de mb IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 13.0059
  • IECEX gas certificate - IECEx PTB 13.0059
  • Languages of the documentation - Brazil, English, French, German, Russian, Spanish
  • Note: Through wiring - max. 3x16 A
  • Ship approval - BVIS, DNVGL

General

  • Functional Description - The 6009 series EXLUX emergency luminaire is suitable for use as safety lighting. It is lightweight and requires minimal maintenance. The battery is housed in the external enclosure and powers the emergency lighting for 1.5 or 3 hours. If one lamp is faulty, the luminaire switches to the working lamp. When the central lock is opened, the luminaire is always disconnected from the power supply at all poles.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Two fluorescent lamps: 18 W and 36 W Weekly function test and annual emergency light duration test
  • Product Description - Emergency luminaire for fluorescent lamps GRP
  • Product Type - 6009/542-9616-1611-71
  • Title Product Variant Technical Data - 6009/542-9616-1611-71 emerg.light 2x36W
  • WebCode - 6009A

Lighting Data

  • Emergency light mode - Continuous light or stand-by light
  • Lamp - G13 lamp base
  • Number of Lamps - 2
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Lighting lock - Central lock , For box spanner actuation
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.300 kg
  • Width - 183.500 mm