Yodify Product Library
Instantly add the Emergency Luminaire with LED EXLUX Series 6009/1 Version IIB+H2 and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Emergency Luminaire with LED EXLUX Series 6009/1 Version IIB+H2

Brand: R. STAHL AG

The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
Features
  • For use in hazardous areas with gas group IIB+H2
  • Emergency luminaire for wall, ceiling, pendant or pole installation
  • Latest LED technology with a high luminous efficacy and a long service life
  • Central locking system
  • Weekly functional test
  • Annually rated operating time test

1 - 10 of 10 Part Numbers
254257
254257
R. STAHL Emergency Luminaire with LED GRP
For use in hazardous areas with gas group IIB+H2

Emergency luminaire for wall, ceiling, pendant or pole installation

Latest LED technology with a high luminous efficacy and a long service life

Central locking system

Weekly functional test

Annually rated operating time test
254258
254258
R. STAHL Emergency Luminaire with LED GRP
For use in hazardous areas with gas group IIB+H2

Emergency luminaire for wall, ceiling, pendant or pole installation

Latest LED technology with a high luminous efficacy and a long service life

Central locking system

Weekly functional test

Annually rated operating time test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Components

  • Ballast - 6046/111-111-020 LED NLE 60 W
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 110.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 110.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - IBExU 16 ATEX 1199
  • ATEX gas certificate - IBExU 16 ATEX 1199
  • Certificate EAC - IBExU16ATEX1199
  • Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
  • Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
  • Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
  • Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIB+H2 T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
  • Gas explosion protection IECEx - Ex db eb mb op is IIB+H2 T4 Gb
  • IECEX dust certificate - IECEx IBE 16.0038
  • IECEX gas certificate - IECEx IBE 16.0038
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A
  • Note: Through wiring 2 - max. 3x10 A

General

  • Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
  • Highlights - For use in hazardous areas with gas group IIB+H2 Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
  • Product Description - Emergency luminaire with LED GRP
  • Product Type - 6009/1481-171-7601-131-00
  • Title Product Variant Technical Data - 6009/1481-171-7601-131-00 LED em.light
  • WebCode - 6009B

Lighting Data

  • Colour rendering - ≥ 80
  • Colour temperature - 5000 K
  • Emergency light mode - Continuous light or stand-by light
  • Lamp - LED
  • Lamp wattage - 52 W
  • Light colour - neutral white
  • Light distribution - 120°x120° with diffusing glass
  • Luminaire efficacy - 90 Im/W
  • Luminous flux - 4700 lm
  • Number of Lamps - 1
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Diffuser - With diffuser
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.350 kg
  • Width - 183.500 mm
254264
254264
R. STAHL Emergency Luminaire with LED GRP
For use in hazardous areas with gas group IIB+H2

Emergency luminaire for wall, ceiling, pendant or pole installation

Latest LED technology with a high luminous efficacy and a long service life

Central locking system

Weekly functional test

Annually rated operating time test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Components

  • Ballast - 6046/111-111-020 LED NLE 60 W
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 110.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 110.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - IBExU 16 ATEX 1199
  • ATEX gas certificate - IBExU 16 ATEX 1199
  • Certificate EAC - IBExU16ATEX1199
  • Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
  • Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
  • Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
  • Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIB+H2 T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
  • Gas explosion protection IECEx - Ex db eb mb op is IIB+H2 T4 Gb
  • IECEX dust certificate - IECEx IBE 16.0038
  • IECEX gas certificate - IECEx IBE 16.0038
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A
  • Note: Through wiring 2 - max. 3x10 A

General

  • Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
  • Highlights - For use in hazardous areas with gas group IIB+H2 Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
  • Product Description - Emergency luminaire with LED GRP
  • Product Type - 6009/1281-171-7601-131-00
  • Title Product Variant Technical Data - 6009/1281-171-7601-131-00 LED em.light
  • WebCode - 6009B

Lighting Data

  • Colour rendering - ≥ 80
  • Colour temperature - 5000 K
  • Emergency light mode - Continuous light or stand-by light
  • Lamp - LED
  • Lamp wattage - 28 W
  • Light colour - neutral white
  • Light distribution - 120°x120° with diffusing glass
  • Luminaire efficacy - 84 Im/W
  • Luminous flux - 2350 lm
  • Number of Lamps - 1
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Diffuser - With diffuser
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 6.700 kg
  • Width - 183.500 mm
254265
254265
R. STAHL Emergency Luminaire with LED GRP
For use in hazardous areas with gas group IIB+H2

Emergency luminaire for wall, ceiling, pendant or pole installation

Latest LED technology with a high luminous efficacy and a long service life

Central locking system

Weekly functional test

Annually rated operating time test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Components

  • Ballast - 6046/111-111-020 LED NLE 60 W
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x SS430 stainless steel
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 110.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 110.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - IBExU 16 ATEX 1199
  • ATEX gas certificate - IBExU 16 ATEX 1199
  • Certificate EAC - IBExU16ATEX1199
  • Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
  • Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
  • Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
  • Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIB+H2 T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
  • Gas explosion protection IECEx - Ex db eb mb op is IIB+H2 T4 Gb
  • IECEX dust certificate - IECEx IBE 16.0038
  • IECEX gas certificate - IECEx IBE 16.0038
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A
  • Note: Through wiring 2 - max. 3x10 A

General

  • Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
  • Highlights - For use in hazardous areas with gas group IIB+H2 Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
  • Product Description - Emergency luminaire with LED GRP
  • Product Type - 6009/1281-171-7601-232-00
  • Title Product Variant Technical Data - 6009/1281-171-7601-232-00 LED em.light
  • WebCode - 6009B

Lighting Data

  • Colour rendering - ≥ 80
  • Colour temperature - 5000 K
  • Emergency light mode - Continuous light or stand-by light
  • Lamp - LED
  • Lamp wattage - 28 W
  • Light colour - neutral white
  • Light distribution - 120°x120° with diffusing glass
  • Luminaire efficacy - 84 Im/W
  • Luminous flux - 2350 lm
  • Number of Lamps - 1
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Diffuser - With diffuser
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 6.750 kg
  • Width - 183.500 mm
256279
256279
R. STAHL Emergency Luminaire with LED GRP
For use in hazardous areas with gas group IIB+H2

Emergency luminaire for wall, ceiling, pendant or pole installation

Latest LED technology with a high luminous efficacy and a long service life

Central locking system

Weekly functional test

Annually rated operating time test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Components

  • Ballast - 6046/111-111-020 LED NLE 60 W
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x SS430 stainless steel
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 52 W
  • Rated operational voltage AC - 110.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 110.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - IBExU 16 ATEX 1199
  • ATEX gas certificate - IBExU 16 ATEX 1199
  • Certificate EAC - IBExU16ATEX1199
  • Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
  • Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
  • Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
  • Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIB+H2 T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
  • Gas explosion protection IECEx - Ex db eb mb op is IIB+H2 T4 Gb
  • IECEX dust certificate - IECEx IBE 16.0038
  • IECEX gas certificate - IECEx IBE 16.0038
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A
  • Note: Through wiring 2 - max. 3x10 A

General

  • Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
  • Highlights - For use in hazardous areas with gas group IIB+H2 Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
  • Product Description - Emergency luminaire with LED GRP
  • Product Type - 6009/1481-171-7611-232-00
  • Title Product Variant Technical Data - 6009/1481-171-7611-232-00 LED em.light
  • WebCode - 6009B

Lighting Data

  • Colour rendering - ≥ 80
  • Colour temperature - 5000 K
  • Emergency light mode - Continuous light or stand-by light
  • Lamp - LED
  • Light colour - neutral white
  • Light distribution - 120°x120° with diffusing glass
  • Luminaire efficacy - 90 Im/W
  • Luminous flux - 4700 lm
  • Number of Lamps - 1
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Diffuser - With diffuser
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.350 kg
  • Width - 183.500 mm
256331
256331
R. STAHL Emergency Luminaire with LED GRP
For use in hazardous areas with gas group IIB+H2

Emergency luminaire for wall, ceiling, pendant or pole installation

Latest LED technology with a high luminous efficacy and a long service life

Central locking system

Weekly functional test

Annually rated operating time test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Components

  • Ballast - 6046/111-111-020 LED NLE 60 W
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x SS430 stainless steel
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 28 W
  • Rated operational voltage AC - 110.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 110.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - IBExU 16 ATEX 1199
  • ATEX gas certificate - IBExU 16 ATEX 1199
  • Certificate EAC - IBExU16ATEX1199
  • Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
  • Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
  • Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
  • Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIB+H2 T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
  • Gas explosion protection IECEx - Ex db eb mb op is IIB+H2 T4 Gb
  • IECEX dust certificate - IECEx IBE 16.0038
  • IECEX gas certificate - IECEx IBE 16.0038
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A
  • Note: Through wiring 2 - max. 3x10 A

General

  • Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
  • Highlights - For use in hazardous areas with gas group IIB+H2 Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
  • Product Description - Emergency luminaire with LED GRP
  • Product Type - 6009/1281-171-7611-232-00
  • Title Product Variant Technical Data - 6009/1281-171-7611-232-00 LED em.light
  • WebCode - 6009B

Lighting Data

  • Colour rendering - ≥ 80
  • Colour temperature - 5000 K
  • Emergency light mode - Continuous light or stand-by light
  • Lamp - LED
  • Light colour - neutral white
  • Light distribution - 120°x120° with diffusing glass
  • Luminaire efficacy - 84 Im/W
  • Luminous flux - 2350 lm
  • Number of Lamps - 1
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Diffuser - With diffuser
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 6.750 kg
  • Width - 183.500 mm
256333
256333
R. STAHL Emergency Luminaire with LED GRP
For use in hazardous areas with gas group IIB+H2

Emergency luminaire for wall, ceiling, pendant or pole installation

Latest LED technology with a high luminous efficacy and a long service life

Central locking system

Weekly functional test

Annually rated operating time test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Components

  • Ballast - 6046/111-111-020 LED NLE 60 W
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 110.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 110.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - IBExU 16 ATEX 1199
  • ATEX gas certificate - IBExU 16 ATEX 1199
  • Certificate EAC - IBExU16ATEX1199
  • Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
  • Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
  • Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
  • Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIB+H2 T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
  • Gas explosion protection IECEx - Ex db eb mb op is IIB+H2 T4 Gb
  • IECEX dust certificate - IECEx IBE 16.0038
  • IECEX gas certificate - IECEx IBE 16.0038
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A
  • Note: Through wiring 2 - max. 3x10 A

General

  • Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
  • Highlights - For use in hazardous areas with gas group IIB+H2 Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
  • Product Description - Emergency luminaire with LED GRP
  • Product Type - 6009/1481-171-7611-131-00
  • Title Product Variant Technical Data - 6009/1481-171-7611-131-00 LED em.light
  • WebCode - 6009B

Lighting Data

  • Colour rendering - ≥ 80
  • Colour temperature - 5000 K
  • Emergency light mode - Continuous light or stand-by light
  • Lamp - LED
  • Lamp wattage - 52 W
  • Light colour - neutral white
  • Light distribution - 120°x120° with diffusing glass
  • Luminaire efficacy - 90 Im/W
  • Luminous flux - 4700 lm
  • Number of Lamps - 1
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Diffuser - With diffuser
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.350 kg
  • Width - 183.500 mm
263413
263413
R. STAHL Emergency Luminaire with LED GRP
For use in hazardous areas with gas group IIB+H2

Emergency luminaire for wall, ceiling, pendant or pole installation

Latest LED technology with a high luminous efficacy and a long service life

Central locking system

Weekly functional test

Annually rated operating time test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Components

  • Ballast - 6046/111-111-020 LED NLE 60 W
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 52 W
  • Rated operational voltage AC - 110.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 110.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - IBExU 16 ATEX 1199
  • ATEX gas certificate - IBExU 16 ATEX 1199
  • Certificate EAC - IBExU16ATEX1199
  • Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
  • Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
  • Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
  • Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIB+H2 T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
  • Gas explosion protection IECEx - Ex db eb mb op is IIB+H2 T4 Gb
  • IECEX dust certificate - IECEx IBE 16.0038
  • IECEX gas certificate - IECEx IBE 16.0038
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A
  • Note: Through wiring 2 - max. 3x10 A

General

  • Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
  • Highlights - For use in hazardous areas with gas group IIB+H2 Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
  • Product Description - Emergency luminaire with LED GRP
  • Product Type - 6009/1481-171-7611-131-01
  • Title Product Variant Technical Data - 6009/1481-171-7611-131-01 LED em.light
  • WebCode - 6009B

Lighting Data

  • Colour rendering - ≥ 80
  • Colour temperature - 5700 K
  • Emergency light mode - Continuous light or stand-by light
  • Lamp - LED
  • Light colour - neutral white
  • Light distribution - 120°x120° with diffusing glass
  • Luminaire efficacy - 100 Im/W
  • Luminous flux - 5200 lm
  • Number of Lamps - 1
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66/IP67
  • Design size - 4
  • Diffuser - With diffuser
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.350 kg
  • Width - 183.500 mm
264445
264445
R. STAHL Emergency Luminaire with LED GRP
For use in hazardous areas with gas group IIB+H2

Emergency luminaire for wall, ceiling, pendant or pole installation

Latest LED technology with a high luminous efficacy and a long service life

Central locking system

Weekly functional test

Annually rated operating time test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Components

  • Ballast - 6046/111-111-020 LED NLE 60 W
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 4 x M25
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x SS316L stainless steel
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 110.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 110.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - IBExU 16 ATEX 1199
  • ATEX gas certificate - IBExU 16 ATEX 1199
  • Certificate EAC - IBExU16ATEX1199
  • Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
  • Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
  • Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
  • Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIB+H2 T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
  • Gas explosion protection IECEx - Ex db eb mb op is IIB+H2 T4 Gb
  • IECEX dust certificate - IECEx IBE 16.0038
  • IECEX gas certificate - IECEx IBE 16.0038
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A
  • Note: Through wiring 2 - max. 3x10 A

General

  • Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
  • Highlights - For use in hazardous areas with gas group IIB+H2 Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
  • Product Description - Emergency luminaire with LED GRP
  • Product Type - 6009/1481-171-7612-145-00
  • Title Product Variant Technical Data - 6009/1481-171-7612-145-00 LED e.light52W
  • WebCode - 6009B

Lighting Data

  • Colour rendering - ≥ 80
  • Colour temperature - 5000 K
  • Emergency light mode - Continuous light or stand-by light
  • Lamp - LED
  • Lamp wattage - 52 W
  • Light colour - neutral white
  • Light distribution - 120°x120° with diffusing glass
  • Luminaire efficacy - 90 Im/W
  • Luminous flux - 4700 lm
  • Number of Lamps - 1
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 4
  • Diffuser - With diffuser
  • Dimension L3 - 670.000 - 930.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 1467.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 9.300 kg
  • Width - 183.500 mm
264446
264446
R. STAHL Emergency Luminaire with LED GRP
For use in hazardous areas with gas group IIB+H2

Emergency luminaire for wall, ceiling, pendant or pole installation

Latest LED technology with a high luminous efficacy and a long service life

Central locking system

Weekly functional test

Annually rated operating time test

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature max.2 - +55 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C

Components

  • Ballast - 6046/111-111-010 (110 - 240 V)
  • Battery-Version - NiCd battery, gas-tight
  • Drilled holes - 4 x M25
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x SS316L stainless steel
  • Through wiring - with 6 conductors 2.5 mm2

Electrical Data

  • Battery capacity - 7 Ah
  • Battery operating voltage - 6 V
  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 28 W
  • Rated operational voltage AC - 110.00 - 240.00 V
  • Rated operational voltage max. AC - 240.00 V
  • Rated operational voltage min. AC - 110.00 V
  • Self-test function - with (Standard)

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Ambient temperature °C 2 - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - IBExU 16 ATEX 1199
  • ATEX gas certificate - IBExU 16 ATEX 1199
  • Certificate EAC - IBExU16ATEX1199
  • Certificates - ATEX (IBE), EAC (Sertium), IECEx (IBE)
  • Dust explosion protection ATEX - II 2 D Ex tb op is IIIC T100 °C Db
  • Dust explosion protection EAC - Ex tb op is IIIC T100°C Db
  • Dust explosion protection IECEx - Ex tb op is IIIC T100 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb mb op is IIB+H2 T4 Gb
  • Gas explosion protection EAC - 1 Ex d e mb op is IIB+H2 T4 Gb X
  • Gas explosion protection IECEx - Ex db eb mb op is IIB+H2 T4 Gb
  • IECEX dust certificate - IECEx IBE 16.0038
  • IECEX gas certificate - IECEx IBE 16.0038
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A
  • Note: Through wiring 2 - max. 3x10 A

General

  • Functional Description - The luminaires of the series EXLUX 6009 LED can be used for safety lighting.
  • Highlights - For use in hazardous areas with gas group IIB+H2 Emergency luminaire for wall, ceiling, pendant or pole installation Latest LED technology with a high luminous efficacy and a long service life Central locking system Weekly functional test Annually rated operating time test
  • Product Description - Emergency luminaire with LED GRP
  • Product Type - 6009/1281-171-7612-145-00
  • Title Product Variant Technical Data - 6009/1281-171-7612-145-00 LED e.light28W
  • WebCode - 6009B

Lighting Data

  • Colour rendering - ≥ 80
  • Colour temperature - 5000 K
  • Emergency light mode - Continuous light or stand-by light
  • Lamp - LED
  • Light colour - neutral white
  • Light distribution - With 130° diffusing glass
  • Luminaire efficacy - 84 Im/W
  • Luminous flux - 2350 lm
  • Number of Lamps - 1
  • Operating time - 1.5 / 3h emergency lighting operation

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 6.00 mm²
  • Degree of protection IP (IEC 60598) - IP66 / IP67
  • Design size - 2
  • Diffuser - With diffuser
  • Dimension L3 - 320.000 - 480.000 mm
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3 + L´
  • Length - 857.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 6.600 kg
  • Width - 183.500 mm
1 - 10 of 10 Part Numbers

Documentation

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more