Standard Enclosure for Remote I/O Series 7145

Brand: R. STAHL AG

With the IS1+ standard enclosures for Zone 2, we offer you a variety of prefabricated field enclosures made from stainless steel 1.4301 (V2A). 

They include all entries, bus rails, cable ducts and connection terminals for auxiliary power. 

Once the IS1+ components (available separately) have been installed, the enclosures can be used in Zone2 without acceptance, and they fulfil the requirements of EN 61439.
Features
  • Short delivery times (no more than 3 weeks)
  • Can be used in Zone 2 without acceptance or certification
  • Prefabricated and ready for use with entries, bus rails, connection terminals, etc.
  • Modifications, add-ons and customer-specific adaptations possible

1 - 5 of 5 Part Numbers
260145
260145
R. STAHL IS1 RIO Station with Shield Bus and Power Terminals
Short delivery times (no more than 3 weeks)

Can be used in Zone 2 without acceptance or certification

Prefabricated and ready for use with entries, bus rails, connection terminals, etc.

Modifications, add-ons and customer-specific adaptations possible

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 1 - 1 x BusRail for 6 slots (1 x CPM, 5 x I/O – modules)

Electrical Data

  • Rated operational voltage DC - 24.00 - 24.00 V
  • Rated operational voltage DC - 24.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2
  • ATEX gas certificate - PTB 09 ATEX 1129
  • Certificates - ATEX (PTB), IECEx (TUR), India (PESO)
  • Gas explosion protection ATEX - II 3 G Ex nA ib [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA e * IIA ... IIC T3...T6 Gc X
  • Gas explosion protection IECEx - Ex nA ib [ia Ga] IIC T4 Gc
  • IECEX gas certificate - IECEx TUR 15.0027
  • Installation - Zone 2

General

  • Functional Description - With the IS1+ standard enclosures for Zone 2, we offer you a variety of prefabricated field enclosures made from stainless steel 1.4301 (V2A). They include all entries, bus rails, cable ducts and connection terminals for auxiliary power. Once the IS1+ components (available separately) have been installed, the enclosures can be used in Zone 2 without acceptance, and they fulfil the requirements of EN 61439.
  • Highlights - Short delivery times (no more than 3 weeks) Can be used in Zone 2 without acceptance or certification Prefabricated and ready for use with entries, bus rails, connection terminals, etc. Modifications, add-ons and customer-specific adaptations possible
  • Product Description - IS1 RIO station With shield bus And power terminals
  • Product Type - IS1 RIO Station360x750x230_6 Slot_Z2
  • Title Product Variant Technical Data - IS1 RIO Station 360x750x230_6 Slot_Z2
  • WebCode - 7145F

Mechanical Data

  • Connection cross-section - 0.2-10 mm²
  • Degree of protection (IP) - IP65
  • Depth - 230.000 mm
  • Dimensions (WxHxD) - 360.000 mm x 750.000 mm x 230.000 mm
  • Enclosure material - 1.4301 stainless steel
  • Height - 750.000 mm
  • Silicone-free - No
  • Wall thickness - 2.00 mm
  • Weight - 25.000 kg
  • Width - 360.000 mm
260146
260146
R. STAHL IS1 RIO Station with Shield Bus with Cable Duct and Power Terminals
Short delivery times (no more than 3 weeks)

Can be used in Zone 2 without acceptance or certification

Prefabricated and ready for use with entries, bus rails, connection terminals, etc.

Modifications, add-ons and customer-specific adaptations possible

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 1 - 1 x BusRail for 8 slots (1 x CPM, 7 x I/O – modules)

Electrical Data

  • Rated operational voltage DC - 24.00 V
  • Rated operational voltage DC - 24.00 - 24.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2
  • ATEX gas certificate - PTB 09 ATEX 1129
  • Certificates - ATEX (PTB), IECEx (TUR), India (PESO)
  • Gas explosion protection ATEX - II 3 G Ex nA ib [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA e * IIA ... IIC T3...T6 Gc X
  • Gas explosion protection IECEx - Ex nA ib [ia Ga] IIC T4 Gc
  • IECEX gas certificate - IECEx TUR 15.0027
  • Installation - Zone 2

General

  • Functional Description - With the IS1+ standard enclosures for Zone 2, we offer you a variety of prefabricated field enclosures made from stainless steel 1.4301 (V2A). They include all entries, bus rails, cable ducts and connection terminals for auxiliary power. Once the IS1+ components (available separately) have been installed, the enclosures can be used in Zone 2 without acceptance, and they fulfil the requirements of EN 61439.
  • Highlights - Short delivery times (no more than 3 weeks) Can be used in Zone 2 without acceptance or certification Prefabricated and ready for use with entries, bus rails, connection terminals, etc. Modifications, add-ons and customer-specific adaptations possible
  • Product Description - IS1 RIO station With shield bus With cable duct And power terminals
  • Product Type - IS1 RIO Station600x600x230_8 Slot_Z2
  • Title Product Variant Technical Data - IS1 RIO Station 600x600x230_8 Slot_Z2
  • WebCode - 7145F

Mechanical Data

  • Connection cross-section - 0.2-10 mm²
  • Degree of protection (IP) - IP65
  • Depth - 230.000 mm
  • Dimensions (WxHxD) - 600.000 mm x 600.000 mm x 230.000 mm
  • Enclosure material - 1.4301 stainless steel
  • Height - 600.000 mm
  • Silicone-free - No
  • Wall thickness - 2.00 mm
  • Weight - 35.000 kg
  • Width - 600.000 mm
260147
260147
R. STAHL IS1 RIO Station with Shield Bus and Power Terminals
Short delivery times (no more than 3 weeks)

Can be used in Zone 2 without acceptance or certification

Prefabricated and ready for use with entries, bus rails, connection terminals, etc.

Modifications, add-ons and customer-specific adaptations possible

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 1 - 1 x BusRail for 10 slots (1 x CPM, 9 x I/O – modules)

Electrical Data

  • Rated operational voltage DC - 24.00 - 24.00 V
  • Rated operational voltage DC - 24.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2
  • ATEX gas certificate - PTB 09 ATEX 1129
  • Certificates - ATEX (PTB), IECEx (TUR), India (PESO)
  • Gas explosion protection ATEX - II 3 G Ex nA ib [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA e * IIA ... IIC T3...T6 Gc X
  • Gas explosion protection IECEx - Ex nA ib [ia Ga] IIC T4 Gc
  • IECEX gas certificate - IECEx TUR 15.0027
  • Installation - Zone 2

General

  • Functional Description - With the IS1+ standard enclosures for Zone 2, we offer you a variety of prefabricated field enclosures made from stainless steel 1.4301 (V2A). They include all entries, bus rails, cable ducts and connection terminals for auxiliary power. Once the IS1+ components (available separately) have been installed, the enclosures can be used in Zone 2 without acceptance, and they fulfil the requirements of EN 61439.
  • Highlights - Short delivery times (no more than 3 weeks) Can be used in Zone 2 without acceptance or certification Prefabricated and ready for use with entries, bus rails, connection terminals, etc. Modifications, add-ons and customer-specific adaptations possible
  • Product Description - IS1 RIO station With shield bus And power terminals
  • Product Type - IS1 RIO Station360x1300x230_10 Slot_Z2
  • Title Product Variant Technical Data - IS1 RIO Station 360x1300x230_10 Slot_Z2
  • WebCode - 7145F

Mechanical Data

  • Connection cross-section - 0.2-10 mm²
  • Degree of protection (IP) - IP65
  • Depth - 230.000 mm
  • Dimensions (WxHxD) - 360.000 mm x 1300.000 mm x 230.000 mm
  • Enclosure material - 1.4301 stainless steel
  • Height - 1300.000 mm
  • Silicone-free - No
  • Wall thickness - 2.00 mm
  • Weight - 45.000 kg
  • Width - 360.000 mm
260148
260148
R. STAHL IS1 RIO Station with Shield Bus with Cable Duct and Power Terminals
Short delivery times (no more than 3 weeks)

Can be used in Zone 2 without acceptance or certification

Prefabricated and ready for use with entries, bus rails, connection terminals, etc.

Modifications, add-ons and customer-specific adaptations possible

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 1 - 1 x BusRail for 12 slots (1 x CPM, 11 x I/O – modules)

Electrical Data

  • Rated operational voltage DC - 24.00 V
  • Rated operational voltage DC - 24.00 - 24.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2
  • ATEX gas certificate - PTB 09 ATEX 1129
  • Certificates - ATEX (PTB), IECEx (TUR), India (PESO)
  • Gas explosion protection ATEX - II 3 G Ex nA ib [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA e * IIA ... IIC T3...T6 Gc X
  • Gas explosion protection IECEx - Ex nA ib [ia Ga] IIC T4 Gc
  • IECEX gas certificate - IECEx TUR 15.0027
  • Installation - Zone 2

General

  • Functional Description - With the IS1+ standard enclosures for Zone 2, we offer you a variety of prefabricated field enclosures made from stainless steel 1.4301 (V2A). They include all entries, bus rails, cable ducts and connection terminals for auxiliary power. Once the IS1+ components (available separately) have been installed, the enclosures can be used in Zone 2 without acceptance, and they fulfil the requirements of EN 61439.
  • Highlights - Short delivery times (no more than 3 weeks) Can be used in Zone 2 without acceptance or certification Prefabricated and ready for use with entries, bus rails, connection terminals, etc. Modifications, add-ons and customer-specific adaptations possible
  • Product Description - IS1 RIO station With shield bus With cable duct And power terminals
  • Product Type - IS1 RIO Station760x760x300x12 Slot_Z2
  • Title Product Variant Technical Data - IS1 RIO Station 760x760x300_12 Slot_Z2
  • WebCode - 7145F

Mechanical Data

  • Connection cross-section - 0.2-10 mm²
  • Degree of protection (IP) - IP65
  • Depth - 300.000 mm
  • Dimensions (WxHxD) - 760.000 mm x 760.000 mm x 300.000 mm
  • Enclosure material - 1.4301 stainless steel
  • Height - 760.000 mm
  • Silicone-free - No
  • Wall thickness - 2.00 mm
  • Weight - 55.000 kg
  • Width - 760.000 mm
260149
260149
R. STAHL IS1 RIO Station with Shield Bus with Cable Duct and Power Terminals
Short delivery times (no more than 3 weeks)

Can be used in Zone 2 without acceptance or certification

Prefabricated and ready for use with entries, bus rails, connection terminals, etc.

Modifications, add-ons and customer-specific adaptations possible

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Built-in unit 1 - 1 x BusRail for 16 slots (1 x CPM, 15 x I/O – modules)

Electrical Data

  • Rated operational voltage DC - 24.00 V
  • Rated operational voltage DC - 24.00 - 24.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 2
  • ATEX gas certificate - PTB 09 ATEX 1129
  • Certificate EAC - TS RU S-DE.MN04.V.00403
  • Certificates - ATEX (PTB), IECEx (TUR), India (PESO)
  • Gas explosion protection ATEX - II 3 G Ex nA ib [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA e * IIA … IIC T6 … T3 Gc X
  • Gas explosion protection IECEx - Ex nA ib [ia Ga] IIC T4 Gc
  • IECEX gas certificate - IECEx TUR 15.0027
  • Installation - Zone 2

General

  • Functional Description - With the IS1+ standard enclosures for Zone 2, we offer you a variety of prefabricated field enclosures made from stainless steel 1.4301 (V2A). They include all entries, bus rails, cable ducts and connection terminals for auxiliary power. Once the IS1+ components (available separately) have been installed, the enclosures can be used in Zone 2 without acceptance, and they fulfil the requirements of EN 61439.
  • Highlights - Short delivery times (no more than 3 weeks) Can be used in Zone 2 without acceptance or certification Prefabricated and ready for use with entries, bus rails, connection terminals, etc. Modifications, add-ons and customer-specific adaptations possible
  • Product Description - IS1 RIO station With shield bus With cable duct And power terminals
  • Product Type - IS1 RIO Station800x1000x300_16 Slot_Z2
  • Title Product Variant Technical Data - IS1 RIO Station 800x1000x300_16 Slot_Z2
  • WebCode - 7145F

Mechanical Data

  • Connection cross-section - 0.2-10 mm²
  • Degree of protection (IP) - IP65
  • Depth - 300.000 mm
  • Dimensions (WxHxD) - 800.000 mm x 1000.000 mm x 300.000 mm
  • Enclosure material - 1.4301 stainless steel
  • Height - 1000.000 mm
  • Silicone-free - No
  • Wall thickness - 2.00 mm
  • Weight - 70.000 kg
  • Width - 800.000 mm
1 - 5 of 5 Part Numbers