The model EJA115 Low Flow Transmitter is a flowmeter comprised of a differential pressure transmitter with an integral orifice and excellent for very low flow measurement.

It outputs a 4-20 mA DC signal corresponding to the measured flow. 

The orifice is available in six types with a bore ranging from 0.508 mm to 6.350 mm. The combination of the bore selection with the differential pressure measurement span variation of the differential pressure transmitter enables a wide range of very small flow measurement. 

The model EJA115 also features remote setup and monitoring through communications with the model BT200/100 BRAIN TERMINAL, CENTUM CS/XL system etc.
Features
  • 5% Flow Span (Accuracy)
  • External Zero Adjust

Specifications

Accuracy

  • ± 5 % of Span

Alarm

  • Down-Scale: -2.5 %, 3.6 mA DC or Less
  • Down-Scale: -5 %, 3.2 mA DC or Less
  • Up-Scale: 110 %, 21.6 mA DC or more

Ambient Temperature Range

  • -30° to 80° C (-22° to 176° F) - with Integral Indicator
  • -40° to 85° C (-40° to 185° F) - General-Use Typical

Approvals & Certifications

  • Leak Test
  • Mill Certificate
  • Pressure Test

Approvals & Certifications

  • CSA Explosion-proof & Intrinsically Safe
  • EMC EN 61326-1 Class A, EN 61326-2-3
  • FM Explosion-proof & Intrinsically Safe
  • IECEx Intrinsically Safe, Typical N & Flameproof Approval
  • NAMUR NE43
  • PED 97/23/EC
  • TIIS Flameproof & Intrinsically Safe

BSP Connection

  • 1/2" BSPT Female

Cable Material

  • Polyethylene Insulated PVC Sheathed

Communication

  • BRAIN
  • FOUNDATION Fieldbus
  • HART
  • PROFIBUS PA

Connection Material

  • JIS SCS14A

Damping Adjustment

  • 0.1 to 64 seconds in 9 Increments

Diaphragm Material

  • ASTM N10276
  • Hastelloy C-276

Differential Pressure

  • psi: 0.145 to 1.45 (kPa: 1 to 10, bar: 0.01 to 0.1) - Capsule L
  • psi: 0.29 to 14.5 (kPa: 2 to 100, bar: 0.02 to 1) - Capsule M
  • psi: 2.901 to 30.46 (kPa: 20 to 210, bar: 0.2 to 2.1) - Capsule H

Display

  • LCD Display

Distance

  • 2 Kilometers - Communication Distance

Drain, Vent Valves & Plug

  • 316 Stainless Steel

Electrical Connectors

  • 1/2" NPT Female
  • G 1/2" Female
  • M20 Female
  • PG13.5

Electrical Protection

  • Lightning Protection

Enclosure Finish

  • Deep Sea Moss Green (Munsell 0.6 GY3.1/2.0)
  • Epoxy Resin Coating
  • Polyurethan Resin Baked Finish

Enclosure, Body Material

  • 316 Stainless Steel
  • Cast Aluminum Alloy
  • JIS SCS14A

Environmental Protection

  • IP67
  • NEMA 4X

Fill Material

  • Fluorinated Oil

Flange Material

  • JIS SCS14A - Cover Flange
  • JIS SUS630 - Cover Flange

Flow Rate

  • 0.004 to 1.9 gpm (0.016 to 7.2 LPM) to Water - Capsule L
  • 0.005 to 6.076 gpm (0.022 to 23 LPM) to Water - Capsule M
  • 0.02 to 8.72 gpm (0.07 to 33 LPM) to Water - Capsule H
  • 0.44 to 198 Nl/min to Air - Capsule L
  • 0.63 to 635 NL/min to Air - for Capsule M
  • 2 to 910 Nl/min to Air - Capsule H

Gasket Material

  • PTFE (Teflon) - Process Connector Gasket
  • Teflon-Coated JIS SUS316L - Capsule Gasket

Humidity

  • 5 to 100 % RH at 40° C (104° F) - Ambient Humidity

Input Impedance

  • 10 kΩ or more at 2.4 kHz

Length

  • 1.33" (34 mm) - Standard Vent Length
  • 4.6" (119 mm) - Total Vent Length

Load

  • 0.22 µF or Less - Load Capacitance
  • 3.3 MH or Less - Load Inductance

Materials of Construction

  • JIS 304 Stainless Steel - Tag Plate, Mounting Bracket
  • JIS 316 Stainless Steel - Tag Plate, Mounting Bracket
  • JIS SECC - Mounting Bracket

Mounting

  • 2" (50.8 mm) Pipe

Mounting Position

  • Horizontal Impulse Piping Typical
  • Vertical Impulse Piping Typical

Mounting Position Effect

  • 390 Pa (40 mmH₂O)/90°

NACE & NIST

  • NACE

NPT Connection

  • 1/2" NPT Female

Nut & Bolt Material

  • JIS SCM435
  • JIS SUS630

O-Ring Material

  • Fluororubber

Operating Temperature

  • -20° to 80° C (-4° to 176° F)

Orifice Material

  • JIS SUS316

Orifice Size

  • 0.02" to 0.25" (0.508 to 6.350 mm)

Output

  • 3.8 - 20.5 mA - Output Signal Limits
  • 4-20 mA DC (2-Wire)

Power Supply Effect

  • ± 0.005 % per Volt (21.6 - 32 Vdc, 350 ohms)

Pressure Range

  • inH₂O: 0 to 830
  • kPa: 0 to 210
  • mbar: 0 to 2,100
  • mmH₂O: 0 to 21,000
  • psi: 0 to 30.46

Pressure Type

  • Absolute
  • Differential

Process Temperature

  • -40° to 120° C (-40° to 248° F)

Response Time

  • 0.5 second, Max.

Screw Material

  • 316 Stainless Steel

Supply Voltage

  • 10.5-28 Vdc for TIIS Intrinsically Safe Typical
  • 10.5-30 Vdc for Intrinsically Safe, Typical N, Non-Incendive, or Non-Sparking Typical
  • 10.5-32 Vdc for Lightning Protector
  • 10.5-42 Vdc for General Use & Flameproof Typical
  • 16.4-42 Vdc

Update Time

  • 0.125 second

Wetted Materials

  • 316L Stainless Steel - Capsule
  • JIS SUSF316L - Capsule, Manifold

Zero Offset

  • 0.01 % of Span - Continuously Adjustable Resolution