Yodify Product Library
Instantly add the MTL5500 Range Intrinsically Safe Isolators and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
MTL5500 Range Intrinsically Safe Isolators
Brand: MTL Instrumentshe MTL5500 range modules are versatile yet simple to apply; use the latest technology and yet are well proven.
These contrasting attributes stem from the progression of our expertise in the design and manufacture of isolators for intrinsic safety and the application of innovative technology to achieve the required separation and segregation of the circuits.
The MTL5500: DIN-rail mounting and MTL4500: backplane mounting isolators share a common design, differing only in the mechanical mounting and connection methods.
Features- 3-port Isolation as Standard
- Highest Module/Channel Packing Densities
- Low Power Dissipation
- Quick Install and Release Mechanism
- Multi-channel I/O Modules
- Broken Line Monitoring
- Compatible with Preceding MTL Isolator Range for Pluggable Replacements
- Various Models Assessed for Use in Functional Safety Applicatons
Specifications
Brand
Connectors
- Each unit is supplied with signal connectors, as applicable.
- When using crimp ferrules for the hazardous or non-hazardous (safe) signal connectors the metal tube length should be 12 mm and the wire trim length 14 mm.
Isolation
- 250 V RMS, tested at 1500 V RMS minimum, between safe- and hazardous-area terminals.
- 250 V RMS between safe-area circuits and power supply
Supply Voltage
- 20 - 35 V dc
Location of Units
- Safe Area
Terminals
- Accepts conductors of up to 2.5 mm*2 stranded or single-core
Mounting
- T-section 35 mm DIN Rail (7.5 or 15 mm) to EN 50022
Ambient Temperature Limits
- -20° to +60° C (-6° to +140° F) operating
- -40° to +80° C (-40° to +176° F) storage
Humidity
- 5 to 95 % Relative Humidity
Approximate Weight
- 150 g
EMC
- To EN 61326 and NE21
- For 20 ms power interruption compliance, a suitable power supply must be used.
Documentation
Product Information
User Guide
- FSM Safety Manual - Analogue Input Modules pdf 1.9 MB
- FSM Safety Manual - Analogue Output Modules pdf 480 KB
- FSM Safety Manual - Binary Input Modules pdf 1.8 MB
- FSM Safety Manual - Fire Detector Interfaces pdf 802 KB
- FSM Safety Manual - Machine Monitor Interfaces pdf 531 KB
- FSM Safety Manual - Solenoid and Alarm Driver Modules pdf 1.8 MB
- FSM Safety Manual – Safety Proximity Detectors pdf 1.6 MB
- FSM Safety Manual – Trip Amplifier pdf 2.3 MB
- FSM Safety Manual- Analogue Input Modules - A Variants pdf 1.6 MB
- MTL5500 Range Instruction Manual pdf 3.8 MB
- MTL5500 Range Instructions for Safe Use pdf 392 KB