Yodify Product Library
Instantly add the NGC8209 Natural Gas Chromatograph and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
NGC8209 Natural Gas Chromatograph
Brand: ABB GroupThe NGC8209 provides precise and reliable measurement of an extensive range of natural gas values, from C6+ to C9+.
This range includes hydrocarbon dew point, a complex and traditionally difficult-to-measure parameter. But this is just one of the many ways the NGC8209 defies tradition.
After installing the NGC8209, information is readily accessible for use by other programs.
The unit’s single controller seamlessly processes all chromatograms, performs all needed calculations, and reports results in real time, for accurate and timely information on the product in process.
Other applications - alarm processors, trending and reporting software, etc. - can access this information as needed.
Like the NGC8206, the NGC8209 retains this as historical data, to be referred to later for custody transfer, or to verify transmitter operation performance.
With the NGC8209’s easy-to-use, graphical, user-interface software, designated users can directly access information with a laptop PC, or indirectly via a cell phone, satellite, radio, or phone modem.
Features- Three analysis trains, two for N2 through C6+ and one for the C6 through C9+
- Modular software – application based plug-in software modules
- Manifold modules
- Analysis sections contain stream selection solenoids, temperature and pressure regulation, 32 bit digital detector electronics, replaceable column / valve modules and a low power 32 bit digital controller, using Windows CE® (internal to GC unit)
- Microsoft® Windows® based man-machine interface software (PCCU)
- Lithium battery-backed RAM
- Two remote serial digital communications ports; one local port (USB Client)
- One USB Host and one Ethernet port
- Comprehensive diagnostics and wizards available to users
- Three-level security for user access control (Read only, Operate and Read/Write)
- Audit-quality historical data; date and time stamped
Specifications
Brand
Media
- Nitrogen, Methane, Carbon Dioxide, Ethane, Propane, Isobutane, Butane, NeoPentane, IsoPentane, Pentane, Hexanes, Heptane, Octane, Nonanes+
Material of Construction
- Aluminum Alloy (with White Polyester Powder Coating)
Environmental Protection
- ATEX Type 4X (IP66 Equivalent)
- CSA Type 4X
- IECEx IP56
Analysis Time
- Approximately 360 seconds, cycles may be scheduled by user
Repeatability
- ± 0.50 BTU @ 1,000 BTU (± 0.025 %) over Temperature Range
- ± 0.25 BTU @ 1,000 BTU (± 0.0125 %) @ ambient
Storage Temperature
- -22° to 140° F (-30° to 60° C)
Temperature Range
- Cold Weather Enclosure: -40° to 130° F (-40° to 55° C)
- Normal: 0° to 130° F (-18° to 55° C)
Humidity
- 95 % Relative Humidity Non-Condensing
Power Consumption
- Start up: 90 W at 15 Vdc, less than 6 A @ 0° F (-18° C)
- Nominal: 14 W at 15 Vdc, 1300 mA @ 0° F (-18° F)
Certifications & Approvals
- INMETRO Exd 11B + H₂ T6, Class 1 Zone 1
- EMC - EMI/RFI: EN 55022, EN 61000-6-1, EN 61000-4-2, 4-3, 4-4, 4-6, 4-8, CISPR 22-2004
- CE: ATEX II 2G: Ex d, IIB+H₂ T6, Class I, Zone 1
- NEC & CEC Class I, Div. 1, Groups B, C and D, T6: CFR 47, Part 15
- IECEx Exd IIB + H₂ T6, Class I, Zone 1
Miscellaneous Type Approvals
- China Weight & Measures
- BRML (Romania)
- NMI (Netherlands)
- Industry Canada
Communication
- Optional USB Hub (Host and Client) and Ethernet Ports
- One USB MMI (RS-232 or USB)
- Two Serial Digital Ports, Software selectable for RS-232, RS-485, or RS-422
Protocols
- Modbus ASCII or RTU (Modicon, WordSwap, or Danalyzer)
- Modbus / TCP Client
- Modbus / TCP Server
- Totalflow / TCP
- Totalflow Remote / Local MMI
Dimensions
- 17.1 cm x 40.6 cm x 22.9 cm
- 6.75” diameter x 16” long x 9.00” tall
Weight
- Approximately 56 lb (25.4 kg)
- Shipping: Approximately 94 lb (52 kg)
Documentation
Brochure
- Course description - Enrollment instructions for Totalflow courses pdf 568 KB
- Course description - NGC, PGC1000 Level One pdf 180 KB
- Course description - NGC, PGC1000 Level Two pdf 348 KB
- Field service and training options pdf 319 KB
- Totalflow Training Brochure pdf 162 KB
- Course description - Remote Learning - NGC, PGC1000 Fundamentals pdf 188 KB
- Totalflow 2017 Policy Information Guideline pdf 104 KB
- Totalflow 2021 Service Rates Service instruction pdf 120 KB
- Totalflow Analyzer Products pdf 22.9 MB
- Upstream Oil and Gas pdf 3.9 MB
Certificate
Manual
- Safety and Compliance Notice NGC series and PGC 1000 pdf 90 KB
- Technical Bulletin 175 - PCCU Vista Mobile Device Center Installation pdf 118 KB
- Technical bulletin 201 - Windows Mobile Device Center will not open to allow connection to ABB NGC after upgrading to Windows 10 pdf 806 KB
- Technical bulletin 206 - NGC 8200 Series Local USB Communications Port Failure pdf 76 KB
- Technical bulletin 208 - NGC Gas Factor File Modifications for GPA 2172 with Base temp 59 F pdf 281 KB
- User drawing - 2103086, Installation of sample, carrier and calibration lines for dual NGC chromatograph pdf 251 KB
- Cold Weather Enclosure and Equipment Installation for use with NGC8200 Manual (Rev. AB) pdf 3.1 MB
- Landfill Application (Rev. B) Manual pdf 993 KB
- NGC series and PGC 1000 Quick Start Guide pdf 255 KB
- NGC8200 Dual Unit Series User manual pdf 9.8 MB
- NGC8200 User manual pdf 8.6 MB